• Title/Summary/Keyword: 섬유혼입

Search Result 582, Processing Time 0.03 seconds

Material Properties of 3D Printed Mortars Produced with Synthetic Fibers and Biopolymers (합성섬유 및 바이오 폴리머를 혼입한 3D 프린팅 모르타르의 재료특성)

  • Hyo-Jung Kim;Byung-Jae Lee;Yun-Yong Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.4
    • /
    • pp.78-85
    • /
    • 2023
  • In this study, synthetic fibers were applied to reduce shrinkage cracks that may occur in mortar produced by 3D printer. We used a biopolymer in powder form made from cactus stem (CS) as an admixture. The material properties of 3D printed mortar were experimentally evaluated. Replacing methylcellulose(MC) with 10% CS increases compressive strength by 9.84-23.92% regardless of the casting method. In addition, regardless of the casting method, shrinkage change, freeze-thaw resistance, and crack resistance are more effective than Plain. Incorporation of CS increases the polysaccharide macromolecular structure and improves durability. Mortars reinforced with synthetic fibers do not affect compressive strength and freeze-thaw. It is also effective for shrink deformation and crack resistance. Incorporating CS and fibers from 3D-printed mortar was found to be effective for durability and crack resistance.

Comparsions for Flexural Performance of Amorphous Steel Fiber Reinforced Concrete (비정질강섬유보강콘크리트의 휨성능 비교분석)

  • Kim, Byoung-Il;Lee, Sea-Hyun
    • Resources Recycling
    • /
    • v.24 no.3
    • /
    • pp.66-75
    • /
    • 2015
  • The flexural performance of amorphous steel fibers having environmental and economy benefits due to relatively short manufacturing process were evaluated as well as that of hooked steel fibers by varing fiber length and volume fraction. Fiber lengths were 10 mm, 20 mm, 30 mm and fiber volume fractions were varied from 0.3% to 1.2%. Test results with flexural performance showed that mixing design needs to be careful because of relatively high volume of amorphous steel fiber compared to hooked steel fibers. High flexural strength was obtained from both longer fiber length and higher volume fraction. Residual strength and toughness of amorphous steel fiber were similar to that of hooked steel fiber, even though rapid dropping of applied load right after concrete matrix breaking. It can be judged that relatively high ability of energy dissipation around first cracking area relatively overcome rapid dropping of loading.

Compressive Behavior of Hybrid Steel Fiber Reinforced Ultra-High Performance Concrete (하이브리드 강섬유 보강 초고성능 콘크리트의 압축거동)

  • Lim, Woo-Young;Hong, Sung-Gul
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.213-221
    • /
    • 2016
  • Uniaxial compression tests for ultra-high performance hybrid steel fiber reinforced concrete (UHPC) were performed to evaluate the compressive behavior of UHPC. The UHPC for testing contains hybrid steel fibers with a predetermined ratio using a length of 19 mm and 16 mm straight typed steel fibers. Test parameter was determined as a fiber volume ratio to investigate the effect of fiber volume ratio on the strength and secant modulus of elasticity. Test results showed that the compressive strength and elastic modulus of UHPC increased with increasing the fiber volume ratio. Based on the test results, the compressive strength and modulus of elasticity equations were proposed as function of the compressive strength of unreinforced and fiber reinforced UHPC, respectively. The simplified equations for predicting the mechanical properties of the UHPC were a good agreement with the test data. The proposed equations are expected to be applied to the SFRC and UHPC with steel fibers.

Creep Behavior of High-Strength Concrete with Nylon Fibers at Elevated Temperatures (고온을 받은 나일론 섬유 보강 고강도 콘크리트의 크리프 거동)

  • Kim, Young-Sun;Lee, Tae-Gyu;Kim, Woo-Jae;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.627-636
    • /
    • 2011
  • Recently, to prevent explosive spalling of high-strength concrete (HSC) members, the usage of nylon fiber instead of polypropylene fiber has increased. Past experimental studies have been conducted to examine the spalling and mechanical properties of HSC with nylon fibers when exposed to elevated temperature. However, the previous studies on HSC with nylon fibers subjected to high temperatures were performed only on the properties such as spalling, compressive strength, and elastic modulus rather than investigations on to the behaviors such as thermal strain, total strain, steady state creep, and transient creep. Therefore, in this study thermal strain, total strain, steady state creep, and transient creep of HSC mixed with nylon fibers with water to binder ratio of 0.30 to 0.15 were tested. The experimental results showed that nylon fibers did not affect the performance of HSC with nylon fibers at high temperatures. However, HSC with nylon fibers generated a larger transient creep strain than that of HSC without fibers and normal strength concrete.

Fire Resistance of High Strength Concrete Pepending on Curing Method and Polypropylene fiber (양생방법 및 PP 섬유 혼입률 변화에 따른 고강도 콘크리트의 내화특성)

  • Son, Ho-Jung;Pei, Chang-Chun;Kim, Won-Ki;Han, Min-Cheol;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.481-482
    • /
    • 2009
  • This study analyzed fire resistance characteristics of high strength concrete according to changes in curing method and PP fiber content, and the results are as follows. First in case of standard curing, spalling was prevented at PP fiber content of 0.05 % or higher. Autoclave and steam curing showed prevention of spalling at content of 0.1 % or higher. For residual compressive strength, measurement of strength for plain was impossible due to spalling phenomenon. A satisfactory trend was shown with increase in PP fiber content with the strength of about 30 MPa.

  • PDF

A Study on the Strength, Toughness and Crack Control Characteristics of Polypropylene Fiber Reinforced Concrete (폴리프로필렌 합성섬유보강 콘크리트의 강도, 인성 및 균열제어 특성 연구)

  • 오병환;한승환;차수원;백상현
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.305-310
    • /
    • 1995
  • 토목 및 건축재료로서 폴리프로필렌 섬유 모르타르 및 콘크리트의 사용은 미국, 영 국 등지에서 개발되기 시작하여 많은 연구가 진행되어 왔는데, 가격이 저렴하고, 화학적인 안정성과 내구성이 우수하여 그 사용이 점차 증대되고 있는 실정이다. 이러한 폴리프로필렌 섬유의 사용은 모르타르 및 콘크리트가 건조나 냉각에 의해 수축될 때 구속에 의해 발생하 는 인장응력 및 균연을 제어하고, 인성의 증가와 충격, 마모, 피로에 대한 저항성, 내구성을 증대시키는 등의 장점을 가지는 것으로 보고되고 있다. 본 연구에서는 이러한 폴리프로필렌 섬유 모르타르 및 콘크리트의 역학적 거동특성인 압축강도, 인장강도, 인성, 유동성과 균열 특성을 실험적으로 규명하고자 하였다. 실험결과 폴리프로필렌의 혼입량이 증가할수록 압축 강도, 인장강도, 인성의 증가를 보였으나, 혼입향 0.2%를 초과할 경우 유동성, 강도 모두 감 소하는 것을 볼 수 있었다. 그리고 단섬유형 보다는 메쉬 형태의 폴리프로필렌 섬유가 역학 적 특성면에서 우수한 것으로 관찰되었으며, Kraai 방법에 의한 소성수축균열제어 특성 실 험에서 약 45% 이상으 균열감소 (0.1%혼입) 효과를 볼 수 있었다.

  • PDF

A Study of the Characteristic Changes of Self-Compacting Concrete with mixing shifted contents of Steel Fibers (섬유 변화량에 따른 고유동 자기충전 콘크리트의 특성변화에 관한 연구)

  • Lee, Keun-Su;Choi, Yeol;Lee, Jae-Ik;Jung, Woong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.243-244
    • /
    • 2009
  • Fibers reinforced concrete(FRC) has abilities to make up for brittleness fracture as one of the material characteristics of concrete. However, being mixed with steed fibers in concrete mixes could set off a "Fiber Ball". The Fiber ball formation could be one of the main reasons to decrease the quality of Fibers reinforced concrete. In order to eliminate the fiber ball formation and improve the deficient flowablitiy, The necessity of research for fiber reinforced self-compacting concrete(FRC-SCC) should be raised.

  • PDF

Crack Resistance Properties of Fiber Reinforced Concrete with Recycled PET Fiber (재생 PET 섬유가 혼입된 섬유 보강 콘크리트의 균열저항특성)

  • Kim, Sung-Bae;Kim, Hyun-Young;Yi, Na-Hyun;Kim, Jang-Jay-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.545-546
    • /
    • 2009
  • This study was performed to prove the possibility of utilizing short plastic fibers made for recycled polyethylene terephthalate (RPET) as a structural material. To measure of crack control capacity, restrained drying shrinkage cracking test was performed. In order to verify the capacity of RPET fiber, it was compared with poly propylene (PP) fiber, most widely used short synthetic fiber, for fiber volume fraction of 0%, 0.5%, 0.75%, and 1.0%.

  • PDF

Analysis of the Strength Characteristics of Hair Fiber Reinforced Caly Soil (헤어섬유로 보강된 점토흙의 강도 특성 분석)

  • Son, Moorak;Song, Hwasun;Lee, Jaeyong
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.6
    • /
    • pp.15-25
    • /
    • 2015
  • This study aimed at the strength increase of the soft ground and analyzed the strength characteristics of clay soil reinforced with hair fiber which is environmentally friendly. The study varied the length of hair fiber, the amount of hair fiber, the amount of cement, and curing days to investigate both the compressive and tensile strengths and the stress-strain relationship of hair fiber mixed clay soils. The test results indicated that both the compressvie and tensile strengths increased with hair fiber mixed, especially in the tensile strength. In addition, the hair fiber mixed clay soil allowed larger displacement to failure. Based on the test results, it is thought that the environmentally friendly hair fiber could be utilized practically to increase the clay strength in the future.

Spalling Properties of 60, 80MPa High Strength Concrete with Fiber (복합섬유(PP, NY)를 혼입한 60, 80MPa 3성분계 고강도콘크리트의 내화특성)

  • Kim, Seong-Deok;Kim, Sang-Yun;Bae, Ki-Sun;Park, Su-Hee;Lee, Bum-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.4
    • /
    • pp.3-9
    • /
    • 2010
  • Fire resistance and material properties of high-strength concrete (W/B 21.5%, 28.5%) with OPC, BS and FA were tested in this study. Main factors of the test consisted of fiber mixing ratio and W/B. Two types of fiber (NY, PP) mixed with the same weight were used for the test. The fiber mixing ratios were 0%, 0.05%, 0.1%, and 0.2% of the concrete weight. After performing the test, Under the W/B level of 21.5% and 28.5%, the spalling was effectively resisted by using the high strength concrete with fiber mixing ratios of 0.05%~0.1%. Compressive strength, flowability and air content are similar those of the fiberless high-strength concrete with the same W/B.