• Title/Summary/Keyword: 설비설계

Search Result 3,390, Processing Time 0.026 seconds

An Experimental Study on Thrust of Ground and High Altitude by Hydrogen Peroxide/Kerosene Engine (과산화수소-케로신 엔진을 이용한 지상 및 고고도 추력에 대한 실험적 연구)

  • Lee, Yang-Suk;Kim, Joong-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.100-106
    • /
    • 2019
  • Ground and high altitude simulated combustion experiments were conducted using a liquid rocket engine with hydrogen peroxide and kerosene as the propellant. A ground and high altitude simulated combustion test facility was constructed by installing a high altitude model diffuser and TMS (Thrust Measuring System) on a vertical combustion test bench. The thrust characteristics according to altitude were investigated using the combustion test equipment. The diffuser was designed on a 1:4.8 scale to verify the characteristics of the high diffusing diffuser and starting pressure. The cold flow tests were conducted using nitrogen gas, and the performance characteristics and starting characteristics of the scale down diffuser were verified. A diffuser and TMS were installed on the vertical combustion test bench, and the thrust correction equations for the system resistance were derived. The thrust correction equations were derived from the step test and vacuum step test before the actual hot firing test. Nozzles with an operating altitude of 10km were designed. Hot firing tests were conducted to analyze the thrust characteristics according to the operating altitude changes. The actual thrust was calculated using each correction equation with the thrust value measured by the TMS.

Configuration of Fuel Cell Power Generation System through Power Conversion Device Design (전력변환장치 설계를 통한 연료전지 발전시스템 구성)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.129-134
    • /
    • 2021
  • Recently, the demand for electricity is gradually increasing due to the rapid industrial development and the improvement of living standards. In the case of Korea, which is highly dependent on fossil fuels due to such a surge in electricity demand, reduction and freezing of greenhouse gas emissions due to international environmental regulations will immediately lead to a contraction in industrial activities. Accordingly, there are many difficulties in competition with advanced countries that want to link the environment with the country's industrial production activities, and the development of alternative energy as a countermeasure is of great interest around the world. Among these new power generation methods, small-scale power generation facilities with relatively small capacity include photovoltaic generation, wind power generation, and fuel cell generation. Among them, the fuel cell attracts the most attention in consideration of continuous operation, high power generation efficiency, and long-term durability, which are important factors for practical use. Therefore, in this paper, the fuel cell power generation system was researched and constructed by designing the power conversion circuit necessary to finally obtain the AC power used in our daily life by using the DC power generated from the fuel cell as an input.

Numerical Modeling for Effect on Bund Overtopping Caused by a Catastrophic Failure of Chemical Storage Tanks (저장시설의 순간 전량 방출 시 방류벽의 월파 효과에 대한 수치모델링)

  • Min, Dong Seok;Phark, Chuntak;Jung, Seungho
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.42-50
    • /
    • 2019
  • As the industry develops in Korea, the use of hazardous chemicals is increasing rapidly and chemical accidents are increasing accordingly. Most of the chemical accidents are caused by leaks of hazardous chemicals, but there are also accidents in which all the substances are released instantaneously due to sudden high temperature/pressure or defection of the storage tanks. This is called catastrophic failure and its frequency is very low, but consequence is very huge when it occurs. In Korea, there were 15 casualties including three deaths due to catastrophic rupture of water tank in 2013, and 64 instances of failures from 1919 to 2004 worldwide. In case of catastrophic failure, it would be able to overflow outside the bund that reduces the evaporation rate and following consequence. This incident is called overtopping. Overseas, some researchers have been studying the amount of external overflow depending on bund conditions in the event of such an accident. Based on the previous research, this study identified overtopping fraction by condition of bund in accordance with Korea Chemicals Controls Act Using CFD simulation. As a result, as the height increases and the distance to the facility decreases while meeting the minimum standard of the bund capacity, the overtopping effect has decreased. In addition, by identifying the effects of overtopping according to atmospheric conditions, types of materials and shapes of bunds, this study proposes the design of the bund considering the effect of overtopping caused by catastrophic failure with different bund conditions.

Illuminance Effects Affecting to Cognitive Ability of the Elderly (고령자의 인지력에 미치는 조도의 영향)

  • Kim, Myung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.507-512
    • /
    • 2019
  • To study how illuminance affects cognitive ability of the elderly, the elderly's EEG, concentration, HRV and vibra image were measured in a test room with temperature $25[^{\circ}C]$, relative humidity 50[RH%] and air flow speed 0.02[m/sec] by varying illuminance to 100[lux], 300[lux], 600[lux], 1000[lux] and 1500[lux]. Ten active elderly males were selected as subjects. Experiment condition was fixed as 1met of activity amount where the subject is seated and relaxed with cloth amount of 0.7clo. As a result, 1000[lux] was found out to be the most pleasant illuminance for the elderly, because $M{\beta}$ increased by 66.35%, and $S{\alpha}$ increased by 31.57% when the elderly was under 1000[lux] of illuminance. Also, concentration under 1000[lux] increased by 8.83% compared to 100[lux], and the pattern of concentration maintained uniformly. SDNN increased by 74.94% under 1000[lux] compared to 100[lux]. Nervousness decreased by 97.23% under 1000[lux] compared to 100[lux]. Moreover, HRT notably increased and aggression remarkably decreased under illuminance of 1000[lux]. Thus, based on the fact that comfort, concentration and heart stability of the elderly reach the highest under 1000[lux], it is determined that the illuminance has to be considered foremost in designing the elderly's welfare facilities to raise their safety and level of independence.

AC Loss Characteristic Analysis of Superconducting Power Cable for High Capacity Power Transmission (대용량 전력 전송을 위한 초전도 전력케이블의 교류손실 특성 분석)

  • Lee, Seok-Ju
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.2
    • /
    • pp.57-63
    • /
    • 2019
  • In order to facilitate the supply of gradually increasing power demand, it is also necessary to increase the number of power cables for power transmission as well as generation facilities. However, the expansion of electric power cables for supplying power to most urban areas requires a space for installation of additional cables, and the space for installing cables in domestic downtown areas is insufficient at present. The superconducting power cable, which can transmit more power with the same size, has emerged as an alternative to overcome the insufficient cable installation space. However, superconducting power cables, which have the advantage of large power transmission, have some losses in the AC (Alternating Current) system. Therefore, the design and analysis of AC losses are essential to introduce superconducting power cables in AC power transmission systems. In this paper, we analyze the AC loss of various superconducting power cables and consider the actual superconducting power cables and their application to the system. Although there is a theoretical calculation method of AC loss for single superconducting wire, it is not easy to calculate AC loss of superconducting power cable with large number. Therefore, the authors intend to analyze various kinds of superconducting power cable AC loss by using electromagnetic finite element analysis considering E-J (Electric field-Current density) characteristics of superconductivity. The analysis of the AC loss characteristics of the superconducting power cable will be an important factor in the design and development of the superconducting power cable to be applied to the actual system.

Revision of related Regulations and Construction Standards for the Use of Information on Underground Facilities Quality Level (지하시설물 품질등급 정보의 활용을 위한 관련 규정 및 건설기준 개정 방안)

  • Park, Joon Kyu;Kim, Tae Hoon;Kim, Won Dae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.4
    • /
    • pp.343-350
    • /
    • 2022
  • The computerization project for underground facilities in Korea began in earnest after the city gas explosion in Seoul in 1994, and the Daegu subway explosion in 1995. As such a large-scale gas explosion accident caused enormous economic loss including human casualties and potential benefits, the need for computerized for efficient management of underground facilities was greatly emphasized in society. Meantime, computerization of underground facilities has been carried out according to the basic plan for building national geographic information system. In this study, problems were identified based on the current status of construction and management of underground facility information, as well as laws and regulations, and directions for establishing quality standards were presented. In addition, construction work standards such as 「Public Survey Work Regulations」, design standards, standard specifications, and technical specifications, gas technology standards, design standards, and communication works so that underground facility information can be linked and utilized in construction work by examining the linkage of the underground facilities, the targets that can be used for quality level information on underground facilities were derived, and a proposal to revise the construction standards was presented. In the future, if the quality standards are established, it is expected that the accuracy and utilization in the construction field will be increased.

Evaluation of Performance of Grouts and Pipe Sections for Closed-loop Vertical Ground Heat Exchanger by In-situ Thermal Response Test (현장 열응답 시험을 통한 수직 밀폐형 지중열교환기용 그라우트와 열교환 파이프 단면의 성능 평가)

  • Lee, Chul-Ho;Park, Moon-Seo;Min, Sun-Hong;Choi, Hang-Seok;Sohn, Byong-Hu
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.93-106
    • /
    • 2010
  • In performing a series of in-situ thermal response tests, the effective thermal conductivities of six vertical closed-loop ground heat exchangers were experimentally evaluated and compared one another, which were constructed in a test bed in Wonju. To compare thermal efficiency of the ground heat exchangers in field, the six boreholes were constructed with different construction conditions: grouting materials (cement vs. bentonite), different additives (silica sand vs. graphite) and the shape of pipe-sections (general U-loop type vs. 3 pipe-type). From the test results, it can be concluded that cement grouting has a higher effective thermal conductivity than bentonite grouting, and the efficiency of graphite better performs than silica sand as a thermally-enhancing addictive. In addition, a new 3 pipe-type heat exchanger provides less thermal interference between the inlet and outlet pipe than the conventional U-loop type heat exchanger, which results in superior thermal performance. Based on the results from the in-situ thermal response tests, a series of economic analyses have been made to show the applicability of the new addictives and 3 pipe-type heat exchanger.

A research on remodelling of the laboratory of S high school of broadcasting for converting into specialized one in the section of broadcasting industry (방송 산업 분야의 특성화고등학교로 전환을 위한 S방송고등학교의 실험.실습실 리모델링에 관한 연구)

  • Oh, Seung-gyun;Lee, Myung-Eui;Lee, Yong-soon;Kim, Jinsoo
    • 대한공업교육학회지
    • /
    • v.34 no.1
    • /
    • pp.87-112
    • /
    • 2009
  • The aim of this research is to suggest the model of reconstruction and remodelling of S high school of broadcast for converting into a specialized one in the section of broadcast industry. The method of reconstruction of the laboratories by each department is as follows. First, the names of laboratories, ground plans, and perspective drawings are designed according to the principle of constructionism. Second, each department is recommended to install 7 laboratories. For the department of broadcasting facilities, a laboratory of processing broadcasting machines, a laboratory of broadcasting machines, and a laboratory of screen picture machines are needed. For the department of broadcasting, electricity, and communication, a laboratory of image and sound edition, a laboratory of broadcasting and communication, a laboratory of broadcasting system, and a laboratory of stage illumination. For the department of broadcasting stage construction, a laboratory of broadcasting stage building, a laboratory of broadcasting stage design, a laboratory of broadcasting stage decoration and etc. Third, an office room is designed by department in the form of seminar room and places for practice is formed by department to be a laboratory. Fourth, a room for industrial-educational cooperation is installed by department, by which education of industrial-educational cooperation is carried out harmoniously. And one example of a remodeled laboratory by one department is shown with laboratory name, ground plan, perspective drawing, and running method. Especially employment of teachers working both school and business, professional club which is concerned with broadcasting technique, and attraction of enterprise in school is suggested as important elements to manage broadcasting laboratories efficiently. Finally, it is desirable for us to attract private capital, that is, Build-Transfer-Lease(BTL) because much budget is required for purchasing the broadcasting equipments and remodelling the laboratories to succeed as specialized high school on broadcasting section.

Design of a pilot-scale helium heating system to support the SI cycle (파이롯 규모 SI 공정 시험 설비에서의 헬륨 가열 장치 설계)

  • Jang, Se-Hyun;Choi, Yong-Suk;Lee, Ki-Young;Shin, Young-Joon;Lee, Tae-Hoon;Kim, Jong-Ho;Yoon, Seok-Hun;Choi, Jae-Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.157-164
    • /
    • 2016
  • In this study, researchers performed preliminary design and numerical analysis for a pilot-scale helium heating system intended to support full-scale construction for a sulfur-iodine (SI) cycle. The helium heat exchanger used a liquefied petroleum gas (LPG) combustor. Exhaust gas velocity at the heat exchanger outlet was approximately 40 m/s based on computational thermal and flow analysis. The maximum gas temperature was reached with six baffles in the design; lower gas temperatures were observed with four baffles. The amount of heat transfer was also higher with six baffles. Installation of additional baffles may reduce fuel costs because of the reduced LPG exhausted to the heat exchanger. However, additional baffles may also increase the pressure difference between the exchanger's inlet and outlet. Therefore, it is important to find the optimum number of baffles. Structural analysis, followed by thermal and flow analysis, indicated a 3.86 mm thermal expansion at the middle of the shell and tube type heat exchanger when both ends were supported. Structural analysis conditions included a helium flow rate of 3.729 mol/s and a helium outlet temperature of $910^{\circ}C$. An exhaust gas temperature of $1300^{\circ}C$ and an exhaust gas rate of 52 g/s were confirmed to achieve the helium outlet temperature of $910^{\circ}C$ with an exchanger inlet temperature of $135^{\circ}C$ in an LPG-fueled helium heating system.

Performance Test of a 75-tonf Rocket Engine Turbopump (75톤급 액체로켓엔진용 터보펌프 실매질 성능시험)

  • Jeong, Eunhwan;Kwak, Hyun-Duck;Kim, Dae-Jin;Kim, Jin-Sun;Noh, Jun-Gu;Park, Min-Ju;Park, Pyun-Goo;Bae, Jun-Hwan;Shin, Ju-Hyun;Wang, Seong-Won;Yoon, Suck-Hwan;Lee, Hanggi;Jeon, Seong-Min;Choi, Chang-Ho;Hong, Soon-Sam;Kim, Seong-Lyong;Kim, Seung-Han;Woo, Seong-Phil;Han, Yeong-Min;Kim, Jinhan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.2
    • /
    • pp.86-93
    • /
    • 2016
  • Performance tests of a 75-tonf liquid rocket engine turbopump were conducted. The performance of sub-components - two pumps and a turbine - and their power matching were measured and examined firstly near the design speed under the LN2 and kerosene environment. In the real propellant - LOX and kerosene - environment tests, design and off-design performance of turbopump were fully verified in regime of the rocket engine operation. During the off-design performance tests, turbopump running time was set longer than the engine operating time to verify the pump operability and set the pump inlet pressure close to design NPSHr to investigate pump suction capability in parallel. It has been found that developed-turbopump satisfied all of the engine required performances.