• Title/Summary/Keyword: 선량증가비

Search Result 476, Processing Time 0.025 seconds

Measurement dose of Dental Panoramagraphy using a Radiophotoluminescent Glass Rod Detector (유리선량계를 이용한 파노라마 검사의 피폭선량 측정)

  • Kim, Chang-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2624-2628
    • /
    • 2011
  • Exposed dose of a patient was measured by Radiophotoluminescent Glass Rod Detector with a use of a panorama graphic device in dental examination. The effect of exposed dose in optic lens was measured by comparing the different materials of the glasses. Depending on the dental location, the exposed dose distribution was 82.4~2,340uSv. It showed that the maximum difference in dose distribution was over 300%. Thus, when manufacturing the devices, it seemed to require shortening the pre-heat time and additional shielding in order to control the diagnosis and exposed dose. The measurement data of the exposed dose in optic lens was increased 20~75uSv per each test when compared putting on glasses with not wearing. As a result, taking off the glasses is recommended to improve efficiency of the test and minimize the exposed dose during dental panorama graphic examinations.

Element Correction Method of Thermoluminescent Dosimeters (개인 피폭선량계 소자 보정법)

  • 송명재
    • Progress in Medical Physics
    • /
    • v.2 no.1
    • /
    • pp.17-28
    • /
    • 1991
  • Generally, it is an accurate radiation measurement technique for processors fo thermoluminescent dosimenters(TLDs) to characterize each element they use by producing element correction factors(FCFs). TLDs are classified into three groups such as reference. control, and field TLDs. Reference TLDs are used only for the production of ECFs for the control and field TLDs. They are kept locked in a safe place except when it is necessary to use a subset of them to produce ECFs for the control and field TLDs. The ECF of a given element is a measure of the response of the element relative to the mean response of an arbitrarily selected group of reference elements. As TLDs are used in the field, their relative responses to radiation might be decreased due to muliple readings and physical abuse. Therefore, the producditon of ECFs are performed initially and periodically during the field use. This element correction method provides an excellent tool to examine new TLDs and to monitor the reliability of old TLDs. This paper discuss the 10 step procedures developed to produce and examine ECFs.

  • PDF

Quantities and Units in Radiation Dosimetry (방사선량(放射線量) 및 단위(單位))

  • Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.2 no.1
    • /
    • pp.38-46
    • /
    • 1977
  • 오늘날 에너지 공급(供給)을 위한 새로운 해결책(解決策)의 하나로서 등장(登場)한 원자력발전소(原子力發電所), 재래(在來)의 X선(線) 진료(診療) 이외(以外)에 의학계(醫學界)에 도입(導入)된 방사선원(放射線源), 그리고 각종(各種) 전자생산품(電子生産品) 등(等)의 증가현상(增加現象)은 방사선(放射線) 방어(防禦) 문제(問題)와 관련(關聯)하여 보건의학분야(保健醫學分野)에서 종사(從事)하는 사람들에게 지대(至大)한 관심(關心)거리가 되고있다. 그래서, 우선(于先) 방사선(放射線)에 관(關)한 사항(事項)중에서 가장 기초(基礎)가되는 방사선량계측(放射線量計測)에 있어서 그 양(量)과 단위(單位) 문제(問題)가 체계적(體系的)으로 서술(敍述)되었다. 즉(卽) 방사선(放射線)이 인체(人體)에 끼칠 수 있는 해(害)로운 영향(影響)에 그 주안점(主眼點)을 두어 조사선량(照射線量), 흡수선량(吸收線量), 선량당량(線量當量), 그리고 그들의 관계(關係) 및 방사능등(放射能等)에 관(關)하여 토론(討論)되었다. 특(特)히 조사선량률(放射線量率), X는 비(比)감마선선상수(線常數), ($\Gamma$)를 포함(包含)하는 함수(函數)로 표현(表現)되었고, 끝으로 인체(人體) 내부(內部)에 축적(蓄積)된 방사능(放射能)으로부터의 영향(影響)에 의(依)한 이른바 생물학적효과(生物學的效果) (Somatic or Genetic Effects)와 관련(關聯)되는 내부흡수선량율(內部吸收線量率)은 평형흡수선량상수(平衡吸收線量常數)($\Delta_i$)와 흡수율($F_i$)를 포함(包含)하는 수학적(數學的) 모델로 소개(紹介)되었다. 한편 방사능(放射能)은 방사선원(放射線源) 물질(物質)의 자연붕괴율(自然崩壞率)이므로 다른 방사선량(放射線量)들 즉(卽) 조사선량(照射線量), 흡수선량(吸收線量)그리고 선량당량(線量當量)과는 별도(別途)로 취급(取扱)하였음을 부언(附言)한다.

  • PDF

Analysis of Changes in Skin Dose During Weight Loss when Tomotherapyof Nasopharynx Cancer (비인두암 토모테라피 시 체중 감소에 따른 피부선량 변화 분석)

  • Jang, Joon-Young;Kim, Dae Hyun;Choi, Cheon Woong;Kim, Bo-Hui;Park, Cheol-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.99-104
    • /
    • 2016
  • For patients receiving chemotherapy and radiation therapy treatment progresses as vomiting, nausea, weight of the patient because of a loss of appetite it is reduced. The patient's weight and the distance from the skin and the treatment site is expected to be closer, thereby reducing the change in the skin because of this dose. This study tests using a loose see the difference between the volume change appears as the weight of the patient using the same phantom and the phantom body of the patient. To using the same as the position EBT film is attached to the skin of the treatment site and was adjusted to the thickness of the Bolus. And using a computerized treatment planning only tomotherapy equipment was passed under the conditions according to the thickness of the radiation dose. To baseline for accurate reproduction position using the MVCT was applied to treated with verification. By passing a total of three dose reduced the error, it was a measure of the film by using a dedicated scanner, EBT VIDAR scanner. Got an increase in the skin dose is displayed each time the thickness of the bolus reduced, in a bolus was completely removed with the highest value. If the changes appeared dose was greater weight loss patients to chemotherapy and therefore bolus thickness variation considering the weight loss of the patient when applying the tomotherapy of nasopharynx cancer was found that the increase in skin dose be increased. This large patient before treatment due to weight loss over the image verification is considered to be established should consider how to re-create your mask and treatment plan for fixing it.

Effects of Dose Reduction Fiber Shielding Cloth on Scattering Rays in Off-target Site during Angiography (선량저감섬유(Dose Reduction Fiber) 차폐포의 혈관조영술(Angiography) 시술 시 비 시술 부위의 산란선 차폐 효과)

  • Kim, Yong-Jin;Han, Sang-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.393-400
    • /
    • 2020
  • Unlike conventional radiographic examinations, angiointerventional procedures have a high risk of radiation exposure to patients or operators due to prolonged radiation exposure time. This study was undertaken to examine effects of reducing the radiation risk by applying dose reduction fiber (DRF) shielding cloth during angiography. To investigate the properties of DRF shielding cloth, we measured the scattered radiation below and above a human phantom using a glass dosimeter, at site distances 10 cm away from the irradiated field. The results obtained reveal a 15 ~ 31% reduction of scattered radiation in the irradiation field, and 53 ~ 70% reduced radiation measured after phantom transmission. Taken together, our data indicate that application of DRF shielding cloth for radiation reduction at non-procedural sites during interventional procedure results in reduction of scattered doses to patients and operators, without affecting the medical examinations. We propose the use of DRF shielding during angiointerventional procedures, in order to reduce the risk of radiation exposure of patients and operators.

Measurement of Patient Dose from Computed Tomography Using Physical Anthropomorphic Phantom (물리적 팬텀을 이용한 CT 촬영 환자의 피폭 선량 측정 및 평가)

  • Jang, Ki-Won;Lee, Choon-Sik;Kwon, Jung-Wan;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.3
    • /
    • pp.113-119
    • /
    • 2005
  • The computed tomogrpahy(CT) provides a high quality in images of human body but contributes to the relatively high patient dose. The frequency of CT examination is increasing and, therefore, the concerns about the patient dose are also increasing. In this study the experimental determination of patient dose was performed by using a physical anthropomorphic phantom and thermoluminescent dosimeter(TLD). The measurements were done for the both axial and spiral scan mode. As a result the effective doses for each scan mode were 17.78mSv and 10.01 mSv respectively and the fact that the degree of the reduction in the patient dose depends on the pitch scan parameter was confirmed. The measurement methods suggested in this study can be applied for the reassessment of the patient dose when the technique in CT equipment is developed or the protocol for CT scanning is changed.

Verification of Clinical Usefulness of Jaw Tracking in IMRT (IMRT에 있어 Jaw Tracking 의 임상적 유용성 검증)

  • Kim, Jin-young;Kim, Ki-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.105-109
    • /
    • 2020
  • Intensity-modulated radiotherapy(IMRT) has disadvantages such as increasing the low doses of irradiation to normal tissues and accumulated dose for the whole volume by leakage and transmission of the Multi Leaf Collimator (MLC). The accumulated dose and low dose may increase the occurrence of secondary malignant neoplasms. For this reasons, the jaw tracking function of the TrueBeam (Varian Medical Systems, Palo Alto, CA) was developed to reduce the leakage and transmission dose of the MLC with existing linear accelerators. But quantitative analysis of the dose reduction has not been verified. Therefore, in the present study, we intended to verify the clinical possibility of utilizing the jaw tracking function in brain tumor with comparison of treatment plans. To accomplish this, 3 types of original treatment plans were made using Eclipse11 (Varian Medical Systems, Palo Alto, CA): 1) beyond 2 cm distance from the Organs At Risk (OARs); 2) within 2 cm distance from the OARs; and 3) intersecting with the OARs. Jaw tracking treatment plans were also made with copies of the original treatment planning using Smart LMC Version 11.0.31 (Varian Medical Systems, Palo Alto, CA). A comparison between the 2 types of treatment planning methods was performed using the difference of the mean dose and maximum dose to the OARs in cumulative Dose Volume Histogram (DVH). In the DVH comparison, the maximum difference of 0.5 % was observed between the planning methods in the case of over 2 cm distance, and the maximum of 0.6 % was obtained for within the 2 cm distance. For the case intersecting with the OAR, the maximum difference of 2 % was achieved. According to these results, it could be realized that the differences of mean dose and maximum dose to the OARs was larger when the OARs and PTV were closer. Therefore, treatment plans with the jaw tracking function consistently affected the dose reduction and the clinical possibility could be verified.

Induction of Mutants by Irradiation of $\gamma$-Ray on In vitro Shoots of Persimmon (기내$\gamma$-선 처리에 의한 감(Diospyros kaki Thunb.) 돌연변이 유기)

  • 고갑천
    • Korean Journal of Plant Tissue Culture
    • /
    • v.27 no.2
    • /
    • pp.143-148
    • /
    • 2000
  • This study was carried out to know the optimum dose of gamma-ray for the induction of mutation in vitro and the characteristics of the mutants induced by gamma-ray in persimmon (Diospyros kaki Thunb.). The LD50 (50% lethal dose) for in vitro shoots of the cultivar, Nishimurawase was between 1 krad and 2 krad and about 1 krad for the cultivar, Ichikikeijiro. As the dose of gamma-ray increased, the length of shoots decreased and necrosis of buds increased. For the cultivar, Nishmurawase, 37.5∼58.3% shoots rooted and the rooting rate and the number of roots per shoot was low in high gamma-ray. The irradiated young plants which were grown in the growth cabinet for 6 weeks were shorter in shoot length and had more branches than non-irradiated plants. The survival rate of irradiated plants grown in the green house for 3 months was 33%, while 77% for control plants.

  • PDF

Evaluation of the Usefulness for Air Gap Technique in Digital Magnification Mammography (디지털 유방확대촬영술에서 Air gap technique의 유용성 평가)

  • Kim, Mi-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • The purpose of this study was investigated optimal exposure condition in digital magnification mammography to decrease radiation dose and increase image quality of the examinee. Auto mode, the average glandular dose is higher than the manual mode. Average glandular dose and image quality were many differences on between grid and air gap technique in auto mode. However, Average glandular dose and signal-to-noise ratio were not different on between grid and air gap technique in manual mode. The signal-to-noise ratio was increased when using the air-gap technique in both mode. According to result, air gap technique may reduce average glandular dose and increase signal-to-noise ratio in digital magnification mammography.

Dose assessment according to Differences in the Content of Iodine in Contrast Media used in Interventional Procedure (중재적 시술에 사용하는 조영제의 요오드(53I) 함유량 차이에 따른 피폭선량 평가)

  • Bak, Hyeok;Jeon, Ju-Seob;Kim, Yong-Wan;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.3
    • /
    • pp.337-345
    • /
    • 2014
  • The purpose of this study is to evaluate exposure dose and absorbability according to differences in the content of iodine in contrast media used in interventional procedure and angiography. There were 7 levels of iodine content as 240, 270, 300, 320, 350, 370, and 400 I $mg/m{\ell}$. The higher iodine content was, the more elevated exposure dose and absorbability were. The output dose was about 8.5% from iodine content with 350I $mg/m{\ell}$ higher than that with 270 I $mg/m{\ell}$ in TACE. These results mean that contrast media can have an effect on patient's exposure dose and high iodine content contrast media results in elevation of patient's exposure dose.