Verification of Clinical Usefulness of Jaw Tracking in IMRT  

Kim, Jin-young (Department of Radiation Oncology, Dongnam Institute of Radiological and Medical Sciences)
Kim, Ki-Hwan (Department of Radiation Oncology, Chungnam National University)
Publication Information
Journal of the Korean Society of Radiology / v.14, no.2, 2020 , pp. 105-109 More about this Journal
Abstract
Intensity-modulated radiotherapy(IMRT) has disadvantages such as increasing the low doses of irradiation to normal tissues and accumulated dose for the whole volume by leakage and transmission of the Multi Leaf Collimator (MLC). The accumulated dose and low dose may increase the occurrence of secondary malignant neoplasms. For this reasons, the jaw tracking function of the TrueBeam (Varian Medical Systems, Palo Alto, CA) was developed to reduce the leakage and transmission dose of the MLC with existing linear accelerators. But quantitative analysis of the dose reduction has not been verified. Therefore, in the present study, we intended to verify the clinical possibility of utilizing the jaw tracking function in brain tumor with comparison of treatment plans. To accomplish this, 3 types of original treatment plans were made using Eclipse11 (Varian Medical Systems, Palo Alto, CA): 1) beyond 2 cm distance from the Organs At Risk (OARs); 2) within 2 cm distance from the OARs; and 3) intersecting with the OARs. Jaw tracking treatment plans were also made with copies of the original treatment planning using Smart LMC Version 11.0.31 (Varian Medical Systems, Palo Alto, CA). A comparison between the 2 types of treatment planning methods was performed using the difference of the mean dose and maximum dose to the OARs in cumulative Dose Volume Histogram (DVH). In the DVH comparison, the maximum difference of 0.5 % was observed between the planning methods in the case of over 2 cm distance, and the maximum of 0.6 % was obtained for within the 2 cm distance. For the case intersecting with the OAR, the maximum difference of 2 % was achieved. According to these results, it could be realized that the differences of mean dose and maximum dose to the OARs was larger when the OARs and PTV were closer. Therefore, treatment plans with the jaw tracking function consistently affected the dose reduction and the clinical possibility could be verified.
Keywords
Intensity-modulated radiotherapy; Multi Leaf Collimator(MLC); Jaw tracking;
Citations & Related Records
연도 인용수 순위
  • Reference
1 H. Aoyama, D. C. Westerly, T. R. Mackie, G. H. Olivera, et al., "Integral radiation dose to normal structures with conformal external beam radiation," International Journal of Radiation Oncology Biology Physics, Vol. 64, No. 3, pp. 962-369, 2006. https://doi.org/10.1016/j.ijrobp.2005.11.005   DOI
2 M. Ding, F. Newman, B. D. Kavanagh, K. Stuhr, T. K. Johnson, L. E. Gaspar, "Comparative dosimetric study of three-dimensional conformal, dynamic conformal arc, and intensity-modulated radiotherapy for brain tumor treatment using Novalis system," International Journal of Radiation Oncology Biology Physics, Vol. 66, No. 4, pp. 82-26, 2006. https://doi.org/10.1016/j.ijrobp.2005.09.009
3 L. Fenkell, I. Kaminsky, S. Breen, S. Huang, M. V. Prooijen, J. Ringash, "Dosimetric comparison of IMRT vs. 3D conformal radiotherapy in the treatment of cancer of the cervical esophagus," Radiotherapy and Oncology, Vol. 89, No. 3, pp. 287-378, 2008. https://doi.org/10.1016/j.radonc.2008.08.008   DOI
4 U. Hermanto, E. K. Frija, M. J. Lii, E. L. Chang, A. Mahajan, S. Y. Woo, "Intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy for high-grade gliomas: Does IMRT increase the integral dose to normal brain?," International Journal of Radiation Oncology Biology Physics, Vol. 67, No. 4, pp. 1135-1144, 2007. https://doi.org/10.1016/j.ijrobp.2006.10.032   DOI
5 Q. Wu, R. Mohan, "Algorithms and functionality of an intensity modulated radiotherapy optimization system," Medical Physics, Vol. 27, No. 4, pp. 701, 2000. https://doi.org/10.1118/1.598932   DOI
6 S. Joy, G. Starkschall, S. Kry, M. Salehpour, et al., "Dosimetric effects of jaw tracking in step-and-shoot intensity-modulated radiation therapy," Journal of Applied Clinical Medical Physics, Vol. 13, No. 2, pp. 136-145, 2012. https://doi.org/10.1120/jacmp.v13i2.3707   DOI
7 J. I. Kim, J. M. Park, S. Y. Park, C. H. Choi, H. G. Wu, S. J. Ye, "Assessment of potential jawtracking advantage using control point sequences of VMAT planning," Journal of Applied Clinical Medical Physics, Vol. 15, No. 2, pp. 160-168, 2014. https://doi.org/10.1120/jacmp.v15i2.4625   DOI