Biomineralization Strategy of Biocomposites on Regenerated Shell: Chitin Synthesis and Regenerated Shell Formtation by Deformed Oyster Shell (생체복합체의 재생패각 합성전략: 참굴 패각의 변형에 따른 키틴 합성 및 패각재생)

  • Lee, Seungwoo;Park, Seungbin;Yeong, Donghee;Choi, Cheongsong
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.529-534
    • /
    • 2008
  • The normal shell and the regenerated oyster shell, Crassostrea gigas, are separated according to the characteristics of inner shell morphology. To study characteristics of chitin obtained from the regenerated shell, chitin prepared by acid and alkali process is analyzed by FT-IR (Fourier transform infrared spectrometer) and XRD (X-ray Diffractometer). The content of insoluble protein in the normal shell was more than doubled as compared with that in the regenerated shell. A comparison of secondary structure of the normal shell and the regenerated shell revealed that the content of random of the regenerated shell was above 47%, indicating an amount in the structural unordered state. Through amino acid composition analysis and secondary protein structure of soluble protein isolated from the normal shell and the regenerated shell, it was found that there are differences in biomineralization strategy of the regenerated shell as compared to the normal shell. The relatively low hardness of the regenerated shell is caused by the change of amino acid composition and ordered secondary protein structure as compared to hardness of the normal shell.

Fabrication and Biomaterial Characteristics of HA added Ti-Nb-HA Composite Fabricated by Rapid Sintering (급속소결에 의한 HA가 첨가된 Ti-Nb-HA 복합재료의 제조 및 생체재료 특성)

  • Woo, Kee Do;Kim, Sang Hyck;Kim, Ji Young;Park, Sang Hoon
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.1
    • /
    • pp.86-91
    • /
    • 2012
  • Ti-6Al-4V extra low interstitial (ELI) alloy has been widely used as an orthopedic implant material because of its excellent biocompatibility, corrosion resistance and mechanical properties. However, V-free titanium alloys such as Ti-6%Al-7%Nb and Ti-5%Al-2.5%Fe have recently been developed because of the toxicity of V. Hydroxyapatite (HA) is used as a coating material on Ti or Ti biomaterials due to its good biocompatibility. However, HA coated on Ti alloy causes a problem for tissue by peeling off during usage. Therefore, such peeling off during long time usage can be suppressed by adding HA in Ti or Ti alloy composites. The aim of this study was to manufacture an ultra fine grained (UFG) Ti-Nb-HA bulk alloy, which is usually difficult to fabricate using melting and casting technology, by rapid sintering process using high energy mechanical milled (HEMM) powder.

Large Area Deposition of Biomimetic Polydopamine-Graphene Oxide Hybrids using Langmuir-Schaefer Technique (랭뮤어-쉐퍼 기법 이용 생체모사 폴리도파민-산화그래핀 복합체 대면적 적층 기법 연구)

  • Kim, Tae-Ho;Song, Seok Hyun;Jo, Kyung-Il;Koo, Jaseung
    • Journal of Adhesion and Interface
    • /
    • v.20 no.3
    • /
    • pp.110-115
    • /
    • 2019
  • Graphene oxide has been gathering interests as a way to exfoliate graphene. Since the oxidation group of graphene oxide can hydrogen bond with various functional groups, tremendous efforts have been actively conducted to apply various applications. However, graphene oxide alone cannot substantially possess the mechanical properties required for the practical application. Therefore, in this study, polydopamine, which is a bio-mimetic mussel protein-inspired material, was combined with graphene oxide to form a large-area composite membrane at the liquid-gas interface. In addition, the morphology of the polydopamine-graphene oxide composite thin film was also controlled to obtain a composite membrane having a nano-wrinkle structure. It can be expected to be used in the next generation seawater desalination membranes or carbon composites because it can form mechanically superior and sophisticated nanostructures.

골조직 재생 촉진을 위한 Novel Perfusion Bioreactor

  • Lee, Si-U;Heo, Su-Jin;Jang, Ji-Yeon;Jeong, Jae-Yeong;Kim, Seung-Eon;Sin, Jeong-Uk
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.46.2-46.2
    • /
    • 2009
  • In vitro 상에서 골조직을 원활하게 재생하기 위해서는 3차원 지지체를 이용한 세포 배양과 세포 배양 시 세포의 형태와 기능을 유지/향상시키기 위한 인체 내 미세 환경 재현은 필수적이다. 따라서 본 연구에서는 뼈 성분과 유사한 생체 활성 물질인 hydroxyapatite (HA)와 생분해성 고분자인 poly $\varepsilon$-caprolactone (PCL)를 복합재료로 이용하여 내부 연결성이 우수한 골조직 재생용 3차원 지지체를 제작하였으며, 골 재생 능력 향상을 위하여 인체내 골조직의 기계적 미세 환경을 체외에서 구현한 새로운 형태의 perfusion bioreactor system을 개발/적용하였다. 또한 본 연구에서 개발된 perfusion bioreactor system의 생물학적 평가를 위해 MG63 (osteoblast like cell, 한국 세포주 은행)과 New Zealand White Rabbit에서 분리한 중간엽 줄기세포를 골조직 재생용 3차원 지지체에 파종하였다. 48시간 동안 안정화 후 perfusion bioreactor system을 이용하여 기계적 자극을 파종된 세포에 인가하였으며, 배양 기간 동안 세포의 증식 확인 및 형태학적 관찰을 실시하였다. 본 연구 결과, perfusion bioreactor system을 이용하여 기계적 자극을 인가한 실험군에서 세포의 증식 및 활성도가 대조군에 비해 우수함을 확인 할 수 있었다. 따라서, perfusion bioreactor를 이용한 세포 배양은 세포의 활성 향상 및 골조직 재생에 도움이 될 것으로 사료된다. 차후 perfusion bioreactor를 이용한 다양한 패턴의 자극이 골재생 능력 및 중간엽 줄기세포의 골 분화능에 미치는 영향에 대한 연구가 필요할 것으로 사료된다.

  • PDF

Effects of specimens dimension on the flexural properties and testing reliability of dental composite resin (치과용 복합레진의 굽힘 특성과 시험 신뢰도에 미치는 시편 크기의 영향)

  • Im, Yong-Woon;Hwang, Seong-sig;Kim, Sa-hak;Lee, Hae-Hyoung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.273-280
    • /
    • 2017
  • The aim of the present study was to investigate the effects of specimen dimension on the flexural properties and testing reliability of dental composite resin. The composite resin was prepared experimentally by mixing a resin matrix with silanated micrometer glass filler at 50 vol%. Flexural specimens with various dimension in specimen's width were fabricated by light curing using a split metal mold; $25{\times}2{\times}2mm$, $25{\times}2{\times}4mm$, $25{\times}2{\times}6mm$ in length ${\times}$ height ${\times}$ width. The flexural strength and modulus were determined according to ISO 4049 test protocol at a span length of 20 mm (normal-flexural strength; NFS). Another flexural test was conducted using mini-sized specimens ($12{\times}2{\times}2mm$, $12{\times}2{\times}4mm$, $12{\times}2{\times}6mm$) from the broken specimens at a span length of 10 mm (mini-flexural strength; MFS). Data were analyzed with ANOVA and Duncan's post-hoc test and the test reliability was evaluated by Weibull analysis. Results showed that there are generally no significant difference in flexural strength with the increase in the specimen width in NFS and MFS tests. However, the test reliability of flexural strength based on Weibull analysis was largely changed with the variables in the dimension of width and span length. The flexural modulus of NFS was increased as the dimension of specimens width increased while there was no trend in flexural modulus of MFS test. Overall results recommend that the evaluation of flexural properties and the reliability of dental composite resins should be performed with more than one test method.

Effect of Bleaching on Restorative Materials and Restorations-Review (치아미백제가 수복재와 수복물에 미치는 영향에 관한 고찰)

  • Shim, Youn-Soo;Choi, Jae-Yoon
    • Journal of dental hygiene science
    • /
    • v.6 no.3
    • /
    • pp.153-158
    • /
    • 2006
  • Bleaching of vital and nonvital teeth is becoming a more commonly used treatment in the dental office and at home. To improve appearance and remove discoloration, the teeth of specific patients are treated with a variety of bleaching agents. The typical bleaching agents contains carbamide or hydrogen peroxide as the active component. The purpose of the review article was to summarize and discuss the available information concerning the effect of peroxide releasing bleaching agent on dental restorative materials and restorations. Information from all original scientific full papers or reviews listed in PubMed or ISI Web Science were included in the review. Bleaching may exert a negative influence on restorations and restorative materials. Advice is provided based on the current literature to minimize the impact of bleaching treatment on restorative materials and restorations.

  • PDF

Fabrication of PLA/TiO2 nanofibers using melt-electro-spinning (용융전기방사를 이용한 PLA/TiO2 나노섬유의 개발)

  • Hwang, Ji-Young;Kim, Hui-Jin;Park, No-Hyung;Huh, Hoon;Park, Choon-Keun;Yoon, Jong-Won
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.3
    • /
    • pp.124-128
    • /
    • 2011
  • Electrospun webs have been widely investigated for applying to drug delivery system (DDS) because of their high specific surface area and high porosity. In this study, the composite webs of PLA (poly(lactic acid)) and $TiO_2$ were fabricated by melt-electro-spinning method for applying to drug delivery system. The morphologies of PLA/$TiO_2$, webs were observed using scanning electron microscope (SEM) and field emission transmission electron microscope (FE-TEM). The crystal structures of PLA/$TiO_2$ composite webs were confirmed by X-ray diffractometer (XRD).

THE COMPARISON OF LIGHT-CURED COMPOSITE RESIN POLYMERIZATION BY FTIR (FTIR을 이용한 복합레진의 중합도 비교)

  • Lee, Ju-Hyun;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.245-253
    • /
    • 2003
  • The degree of conversion of cross-linked polymer has great importance in determining the physical and mechanical properties, and biocompatibility. Therefore, this study examined the comparison of light-cured composite resin polymerization of various light-curing systems composed of plasma arc, halogen, LED curing units and pluse-delay curing with FTIR. From this experiment, The following results were obtained : 1. From FTIR, the degree of conversion(DC) of composite resin was 34.52-49.31%, DC of composite resin used in Flipo was $39.36{\pm}1.22%$, CrediII $45.64{\pm}1.34%$, XL3000 $43.48{\pm}1.34%$, VIP(mode 4) $44.31{\pm}0.72%$, LUXOMAX $49.31{\pm}2.37%$, Elipar Freelight $44.51{\pm}0.62%$ and $34.52{\pm}0.85%$ in pulse-delay curing. 2. The degree of conversion of composite resin in each light-curing unit was highest DC of the LUXOMAX system, lowest DC of the pulse-delay curing. 3. Compared with other curing system, Flipo, LUXOMAX, and pulse-delay curing were significant difference(p<0.05). 4. In same curing method group, the differences of each light-curing unit were no significace in halogen(conventional) curing method(p>0.05), but significance in plasma arc curing and LED curing method(p<0.05).

  • PDF

Polymerization of dual cured composites by different thickness (두께에 따른 이중 중합형 복합레진의 중합)

  • Kim, Yun-Ju;Jin, Myoung-Uk;Kim, Sung-Kyo;Kwon, Tae-Yub;Kim, Young-Kyung
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.169-176
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of thickness, filling methods and curing methods on the polymerization of dual cured core materials by means of microhardness test. Two dual cured core materials, MultiCore Flow (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Bis-Core (Bisco Inc., Schaumburg, IL, USA) were used in this study. 2 mm (bulky filled), 4 mm (bulky filled), 6 mm (bulky and incrementally filled) and 8 mm (bulky and incrementally filled)-thickness specimens were prepared with light cure or self cure mode. After storage at $37^{\circ}C$ for 24 hours, the Knoop hardness values (KHN) of top and bottom surfaces were measured and the microhardness ratio of top and bottom surfaces was calculated. The data were analyzed using one-way ANOVA and Scheffe multiple comparison test, with ${\alpha}=0.05$. The effect of thickness on the polymerization of dual cured composites showed material specific results. In 2, 4 and 6 mm groups, the KHN of two materials were not affected by thickness. However, in 8 mm group of MultiCore Flow, the KHN of the bottom surface was lower than those of other groups (p < 0.05). The effect of filling methods on the polymerization of dual cured composites was different by their thickness or materials. In 6 mm thickness, there was no significant difference between bulk and incremental filling groups. In 8 mm thickness, Bis-Core showed no significant difference between groups. However, in MultiCore Flow, the microhardness ratio of bulk filling group was lower than that of incremental filling group (p < 0.05). The effect of curing methods on the polymerization of dual cured composites showed material specific results. In Bis-Core, the KHN of dual cured group were higher than those of self cured group at both surfaces (p < 0.05). However, in MultiCore Flow, the results were not similar at both surfaces. At the top surface, dual cured group showed higher KHN than that of self cured group (p < 0.05). However, in the bottom surface, dual cured group showed lower value than that of self cured group (p < 0.05).

  • PDF

Trend of Nano Magnetic Material & Surface treatment (나노자성복합소재와 표면처리 기술동향)

  • Kim, Yu-Sang
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.221-222
    • /
    • 2012
  • 2000년 미국에서 국가나노기술개발 전략을 발표한 이래로 현재 한국, 일본, 유럽연합, 독일, 중국, 대만 등 전 세계 60여개 국가들은 나노기술을 미래 국가 경쟁력을 결정하는 핵심요소로 인식하고, 나노국가기술개발 전략을 수립하고 경쟁하고 있다. 한국은 제 1기 나노기술종합발전계획(2001.7)과 제 2기 나노기술종합발전계획(2005.12)의 수립, 추진을 통하여 지난 10여 년 동안 나노기술연구개발, 첨단 연구시설 구축, 나노전문 인력양성, 나노기술산업화 등의 분야에서 괄목할 만한 많은 성과들을 이룩해 왔다. 특히 한국은 나노기술 경쟁구도에 있어 분기점으로 될 것으로 예상되는 2015년에 나노기술 3대 강국 진입을 목표로 설정하고, 정부의 적극적인 투자와 연구자들의 헌신적인 노력이 경주되고 있다. 최근 스마트폰 등, 이동통신기 대량보급과 함께 나노소재는 암 치료나 생체재료분야의 연구개발이 활성화되고 있다. 본고에서는 최근의 나노자성도금의 특성을 중심으로 기술하였다.

  • PDF