• Title/Summary/Keyword: 상태기준

Search Result 3,576, Processing Time 0.032 seconds

Robust Start-up Circuit for Low Supply-voltage Reference Generator (저전압 기준전압 발생기를 위한 시동회로)

  • Im, Saemin;Park, Sang-Gyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.106-111
    • /
    • 2015
  • Since most reference voltage generator circuits have bi-stable characteristics, it is important to employ a proper start-up circuit to operate a reference generator in the desired state. In this paper, we propose a start-up circuit for a low voltage reference generator. This start-up circuit determines the state of the circuit reliably by measuring the current drawn by BJTs in the circuit, which is well-defined in the desired state. To measure the current using CMOS-compatible devices only, a comparator with an internal offset voltage is used. The reliability of the proposed circuit is confirmed by Monte-Carlo simulations of the start-up operation, which show that, with the proposed start-up circuit, the low voltage reference generator starts reliably with supply voltages over 850mV even in the presence of device mismatches.

Analysis of IEC 62019 standard for Safety Test of Photovoltaic Inverter (태양광인버터 안전성 평가를 위한 IEC 62109 표준화 분석)

  • Lee, Jeong-Hyeon;Yoon, Yong-Ho;Park, jun-Suck;Kim, Jae-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1551-1552
    • /
    • 2015
  • 현재 태양광인버터의 안전성확보에 대한 기술기준이 IEC로부터 채택하게 됨과 동시에 독일, 일본, 미국 등 선진 각국에서는 안전성 확보용 기술기준을 적용하고 있으며, 강제(Mandatary) 규격으로 적용하고 있는 상태이다. 그러나 국내 태양광인버터분야는 인버터의 성능만 수행하고 있는 상태이며, 안전성분야는 전무한 상태이다. 따라서 본 논문에서는 성능위주의 특성에서 벗어나 사용자의 보호 및 안전성을 중심으로 CE, UL 등의 해외인증에서 요구하는 기준으로 자리를 잡아가고 있는 IEC 62109 표준화에 대한 정확한 기술기준 및 시험방법에 대해 살펴본다.

  • PDF

Assessment of Stabilization of An Open-dumping Landfill - A Case Study of Noeun Landfill - (비위생매립지의 안정화 평가 - 노은 매립지 사례연구 -)

  • Hong, Sang-Pyo;Kim, Kwang-Yul
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.2
    • /
    • pp.47-53
    • /
    • 2005
  • 노은 매립지는 사용종료된지 5년이 경과된 비위생매립지로 최종복토는 되어 있으나 침출수 차집시설 및 매립가스 포집설비가 제대로 갖추어지지 않은 상태이다. 환경부의 사용종료 매립 지 정비지침에 의하면 침출수의 BOD/CODcr 비율이 1/10 수준임으로 침출수의 안정화 과정이 거의 완결상태로 진행되고 있는 것으로 판단된다. 매립지 가스의 안정화 측면에서는 CH4의 비 율이 5%정도이기 때문에 안정화가 거의 이루어진 것으로 볼 수 있다. 매립된 쓰레기 중에서 플 라스틱을 제외한 가연물 함량이 3.97 - 9.34%이기 때문에 매립폐기물은 안정화 기준에 미흡한 상태이다. 그리고 지하수는 대장균 항목이 지하수 수질기준 생활용수 기준에 미흡하여 안정화 기준을 충족시키지 못하고 있다. 노은매립지는 매립지 안정화의 속도가 평가 대상별로 상이하 게 진행되는 것으로 평가된다.

Application of PEN Method to Hexagonal Core Neurotics Analysis Benchmark Problems

  • 홍인섭;김창효
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.93-98
    • /
    • 1998
  • PEN(1)(다항식전개 노달) 해법을 육방형 노심의 과도상태 해석과 Adjoint flux(수반 중성자속)해법에 응용하여 여러가지 Benchmark문제들(3)(4)(5)을 풀고 그 결과를 다른 수치기법 결과와 비교·분석하였다. 2차원 육방형 대형중수로 과도상태 Benchmark문제(5)를 다항식전개 노달해법에 의한 과도상태 해석·검증의 대상으로 삼았으며 그 기준 계산치로서 FX2-TH 코드의 계산결과를 사용하였다 대형중수로 노심의 과도상태 해석 결과, 기준해와 비교해 집합체 낙하시작 3초 후에 집합체가 낙하한 위치에서 Normalized Flux 오차가 0.5% 이내, 집합체가 낙하하지 않은 위치에서 Normalized Flux 오차가 1% 이내의 정확한 결과를 보였다. Adjoint flux 해의 검증을 위해서는 VENTURE 코드(2)의 계산 결과를 기준해로 하였으며, 계산능 검증을 위해 사용된 대부분 의 Benchmark 문제들에서 작은 오차를 보였으나 반사체가 포함된 IAEA 문제에서는 큰 오차를 보였다.

  • PDF

Review of Steel ratio Specifications in Korean Highway Bridge Design Code (Limit States Design) for the Design of RC Flexural Members (철근콘크리트 휨부재 설계를 위한 도로교설계기준(한계상태설계법)의 철근비 규정 검토)

  • Lee, Ki-Yeol;Kim, Woo;Lee, Jun-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.277-287
    • /
    • 2017
  • This paper describes the specifications on balanced steel ratio and maximum reinforcement for the design of RC flexural members by the Korean Highway Bridge Design Code based on limit states design. The Korean Highway Bridge Design Code (Limit States Design) is not provide for the balanced steel ratio specification for the calculation of required steel area of RC flexural members design. The maximum steel area limited the depth of the neutral axis at the ultimate limit states after redistribution of the moment, and also recommended the maximum steel area should not exceed 4 percent of the cross sectional area. However, from the maximum neutral axis depth provisions should increase the cross section is calculated to be less the maximum reinforcement area, and according to the 4% of the cross sectional area of the concrete, the tensile strain of the reinforcement is calculated to be greater than double the yielding strain, so can not guarantee a ductile behavior. This study developed a balanced reinforcement ratio that is basis for the required reinforcement calculation for tension-controlled RC flexural members design in the ultimate limit states verification provisons and material properties and applied the ultimate strain of the concrete compressive strength with a simple formular to be applied to design practice induced. And assumed the minimum allowable tensile strain of reinforcement double the yielding strain, and applying correction coefficient up to the ratio of maximum neutral axis depth, proposed maximum steel ratio that can be applied irrespective of the reinforcement yield strength and concrete compressive strength.

법령과 고시 - 조달청 시설공사 집행기준 및 PQ심사기준 개정

  • 대한기계설비건설협회
    • 월간 기계설비
    • /
    • s.319
    • /
    • pp.54-54
    • /
    • 2017
  • 조달청은 중소건설업체의 입찰부담을 완화하고 입찰 경쟁성을 높이기 위해 집행기준을 개정하고 1월 16일 시행에 들어갔다. 개정된 시설공사 집행기준은 적격심사 경영상태 평가기준 완화, 기술개발투자비율 평기기준 완화 등을 담고 있다.

  • PDF

낙동강 강변여과수 개발부지 지하수 수질의 수직분포 특성

  • 현승규;우남칠;신우식
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.321-325
    • /
    • 2004
  • 국내 충적층의 철, 망간 문제는 지속적으로 지적되어오던 수질항목이다. 충적층 지하수 내 철과 망간의 용존 특성을 확인하고자 강변여과수 부지에서 지하수의 수리지화학적 특성을 조사하였다. Fe와 Mn에 의해 오염된 관정은 D-2와 DS-3로 모두 3월에 채취한 시료이며 NO$_3$-N는 모두 0 m/L 이다. NO$_3$-N에 대해 다른 관정은 2 mg/L NO$_3$-N를 넘고 있으며, DS-8와 DS-3에서 11.30과 20.2 mg/L NO$_3$-N의 값으로 먹는물 수질기준을 초과하고 있다. Mn에 대해 오염된 관정은 SJ-3이다. 10월에 채취한 시료에서 DS-2+l8 m에서 채취한 시료가 1.16 mg/L인 것을 제외하고 대부분의 시료가 2 mg/L를 초과하고 있고, DS-6+l3 m과 SJ-3+10 m에서 채취한 시료가 각각 10.71과 10.31 mg/L NO$_3$-N로 먹는물 수질기준을 초과하고 있다. DO 검층 자료와 NO$_3$-N 농도를 이용하여 Fe와 Mn이 먹는물 수질 기준을 초과하는 D-2와 DS-2 관정의 지하수 체의 혐기성 상태임을 확인하였다. 강변여과수 지역은 전반적으로 NO$_3$-N에 대해 인위적인 오염이 발생하고 있으며, 혐기성 상태 구간이 존재함에 따라서 Fe와 Mn이 먹는물 수질 기준을 초과하여 용존 상태로 존재한다.

  • PDF

Development of the Preventive Maintenance Template for Static Exciter in the Nuclear Power Plant (원자력발전소 정지형 여자기의 예방정비기준(PMT) 개발)

  • Chin, Soo-Hwan;Park, Jin-Youb;Hong, Young-Hee
    • Journal of Energy Engineering
    • /
    • v.20 no.2
    • /
    • pp.154-162
    • /
    • 2011
  • PMT(Preventive Maintenance Template) is a standardized maintenance program that describes maintenance items & period as operation condition to increase component reliability at the component level. The existing maintenance programs are focused on time based maintenance to inspect and repair component depend on fixed period. But recently, we have developed advanced maintenance program(named PMT) to increase reliability and optimize maintenance program of the plant significant component. This paper presents how to develop the PMT for nuclear power plant's static exciter.

A Criterion for Interaction Analysis and Loop Pairing Among Control System Variables (제어 시스템 변수들간의 상호작용 해석 및 루프 페어링을 위한 판별기준)

  • Ko Jae Wook;Yoon En Sup;Evans L. B.
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.1
    • /
    • pp.64-74
    • /
    • 1999
  • Using the steady state gains, an appropriate criterion used for the interaction analysis among variables and the loop pairing is suggested. Based upon the suggested criterion derived from the derivative relation of implicit function, the SISO pairing which has minimum interaction among control system variables and good control performance can be determined. The relative effect among diagonal gains and off-diagona gains, which was not considered in other criteria, can be explained deterministically Also, the criterion can be easily applied to partial MIMO pairing. This criterion was applied to several examples to illustrate its usefulness in finding the feasible SISO pairing and MIMO pairing

  • PDF

Towards better acoustic conditions in school buildings in Korea-a need for Korean standard for classroom acoustics (국내 교육시설의 음향기준 제정의 필요성 제고)

  • Young-Ji Choi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.113-123
    • /
    • 2023
  • This paper describes the acoustical conditions of elementary school and high school classrooms as well as university classrooms in Korea and suggests a need for Korean acoustic standards and guidelines for classroom design. Current standards and guidelines of classroom acoustics in several countries were briefly introduced to understand their acoustical performance criteria for background noise levels and reverberation times, and noise isolation design requirements in various types of classrooms. The results of several acoustic survey of domestic classrooms in elementary school, high school, and university were described and compared to provide information of the acoustic characteristics of Korean school classrooms. The survey includes occupied and unoccupied data on the acoustical conditions, noise levels, and noise isolation performance in the classrooms. Acoustical parameter values for achieving 'good' speech intelligibility in active university classrooms were also presented.