• Title/Summary/Keyword: 산란 계수율

Search Result 107, Processing Time 0.022 seconds

TM Wave Scattering by the Perfectly Conducting Strip Loaded with a Dielectric Cylinder (유전체실린더로 둘러 싸인 완전 도체스트립에 의한 TM파의 산란)

  • Kim, Nam-Tae;Lee, Sang-Seol
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.3
    • /
    • pp.7-12
    • /
    • 1990
  • A rigorous analysis of the scattering problem by the perfectly conducting strip loaded with a dielectric cylinder of different permittivity is presented. By introducing auxiliary electromagnetic fields and applying the reciprocity theorem, integral equations for the unknown electric field are derived. These integral equations are transformed into an equivalent matrix equation of infinite order with proper boundary conditions. By calculating inverse matrix of unknown coefficients from this equation, scattered electric fields are determined. In particular case of the dielectric with the same permittivity, the results of this paper correspond to well-known results.

  • PDF

Study of Optical Tomography for Measurement of Spray Characteristics at High Ambient Pressure (고압 환경에서의 분무 특성 계측을 위한 광학 토모그래피 기법 연구)

  • Cho, Seong-Ho;Im, Ji-Hyuk;Choi, Ho-Yeon;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.4
    • /
    • pp.36-44
    • /
    • 2009
  • Spray cross-section was measured by the Optical Line Patternator (OLP) and Optical Tomography at high ambient pressure. The laser line beam passed through the spray region, then Mie scattered signal and transmitted light were captured. The measured signal was processed to obtain a distribution of attenuation coefficient in spray cross-section. Beer-Lambert's law and mathematical reconstruction methods were used to reconstruct the distribution of attenuation coefficient. Spray became dense at high pressure and attenuation of scattered signal occurred seriously. OLP method, which uses Mie scattered signal, showed limit in compensating attenuation problem in dense spray region. Optical tomography reconstructed spray cross-section well, from transmission rate of light penetrating spray region.

Bi-Directional Transmission Assessment Study of Angular Solar Selective Panels (프리즘창의 이차원 투과계수 평가에 관한 연구)

  • Hashmi, Masaood;Akhter, P.;Kim, Ki-Se;Kang, Eun-Chul;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.3
    • /
    • pp.55-63
    • /
    • 2004
  • 빛이 입사각별로 태양투과율이 제어되어지는 첨단 창과 같은 물체를 통과할 때 투과되는 성분은 직달투과와 산란투과성분으로 볼 수 있다. 직달투과는 물체를 통과하면서 일정한 방향으로 굴절되어 투과되는 성질을 말하고, 산란투과는 직달투과를 제외한 나머지 방향의 성분들의 형태를 말한다. 이러한 첨단 창의 냉난방부하에 미치는 에너지성능을 평가하기 위해서는 산란투과에 대한 정보가 필요하고, 이에 대한 물리적 변수는 입사각, 출력각, 양방향 투과율 분산함수인 BTDF로 정의된다. 본 논문에서는 3개의 서로 나른 첨단 창 (1) $42^{\circ}/5^{\circ}$ 프리즘 창 판넬, (2) 레이저 컷 판넬 (3) $45^{\circ}$ 프리즘 3M 필름의 BTDF 데이터 획득을 위한 실험 방안을 소개하고, 실험을 통해 획득한 정보를 이용하여 계산식과 비교 검증을 하였다. 따라서 이 검증된 방안을 이용하여 지역별 냉난방 부하를 최소화 할 수 있는 입사각별로 태양 투과율 제어 판넬을 선정할 수 있게 되었다.

Direct and Diffuse Radiation Data in Naju During May 2019 to November 2020 (농업적 활용을 위한 산란일사와 직달일사 관측 자료: 나주에서 2019년 5월부터 2020년 11월까지)

  • Kim, Hyunki;Moon, Hyun-Dong;Cho, Yuna;Sin, Seo-Ho;Kim, Jong-Hyeon;Lee, Yang-Won;Cho, Jaeil
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.2
    • /
    • pp.134-140
    • /
    • 2021
  • Global solar radiation consists of direct and diffuse radiations. Both components are necessary for not only atmospheric science and solar energy domains but also agricultural applications. In this study, the data of direct and diffuse radiations are uploaded to Github. It was observed in Naju during May 2019 to November 2020. Using this data, the previous empirical equations using the relation between clearness index and diffuse ratio were validated. All coefficients of determination (R2) and RMSE were similar as 0.79~0.80 and 0.13~0.15. However, to get the lower RMSE, other non-linear approaches will be required with more observation data.

Measurements of Transmittances and Calculations of Fundamental Radiative Properties (투과율의 측정 및 이를 이용한 복사물성치의 계산)

  • Hwang, Yong-Ha;Park, Seung-Ho;Lee, Young-Soo
    • Solar Energy
    • /
    • v.14 no.2
    • /
    • pp.29-37
    • /
    • 1994
  • Radiative charaacteristics of glass windows and porous absorbing media which can be used for a solar air heater are determined through the measurements of spectral transmittances. Those in the visible range are measured by the UV-IR spectrometer. Refractive index of glass are obtained by the comparison of the measured transmittances and the correlations derived from the electromagnetic theory and are compared to the theoretical ones calculated from the classical dispersion theory. Absorption and back-scattering coefficients of 15-mesh stainless wire screens are calcuated by the comparison of the measured transmittances and the correlations derived from the two flux model.

  • PDF

Time Trends in Estimates of Genetic Parameters in a Population of Layer Breeders (난용종계 집단에서의 선발에 의한 유전모수 변화 양상)

  • 최연호;오봉국
    • Korean Journal of Poultry Science
    • /
    • v.17 no.4
    • /
    • pp.255-268
    • /
    • 1990
  • This study was carried out to investigate the time-trends of genetic parameters of the dosed flock population which selected for improving egg production. Data for two layer pure lines, Line-W (Single Comb White Leghorn) and Line-B (brown layer) which have been maintained at the Mani Breeding Farm were collected from 1980 to 1985 during 5 generations. The effective number of parents per generation ranged from 148 to 366 in Line-W and 85 to 355 in Line-B, and the cumulative expected inbreeding coefficients during 5 generations of selection were 15% and 1.6%. So inbreeding could not be considered a critical factor on estimating the genetic parameters, heritabilities and genetic correlations Heritabilities of EN 300 and EN 400, primary two selected traits were significantly decreased during 5 generations but the estimates of the other 03its not showed the consistent decreasing pattern significantly. No time trends of probable consequence were evident in the genetic correlation coefficients of the traits studied. The reason for that situation was attributed to the fact that selection was conducted for multiple objectives and the relative importance of selection for the studied traits were not consistent by generations.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

A Study of Uniformity Test in PET/CT (PET/CT 장치의 uniformitly측정에 관한 연구)

  • Kim, Su-Keun;Jung, Hee-Il;Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • The PET scanner can detect the photon pair arriving from the source in phantom. The number of light photons released by the crystal(scintillator-BGO or LSO). In recent scintillation crystals in block structures were incorporated into full ring systems, and their resulted marked improvement in spatial resolution and increase in a sensitivity to annihilations. The uniformity of the crystal sensitivity is very important to makes correct information of abnormal states in organs. These factors influenced by the dection efficiency of the scintillators. We have study about the uniformity of crystals to the annihilation, And study about the standard deviation to average counts. The relative standard deviation in central detector groups more uniformed than circumferenced detector groups. It is caused detected quanta of gamma ray by the geometrical factors of PET detector. PET cameras are available with different geometric arrangement and several parallel rings oriented in the axial direction. The center groups from 7th to 40th groups are comparatively uniform and sensitive. But at the circumferenced detectors decreased the sensitivity and uniformity.

  • PDF

Analysis of the Electromagnetic Scattering by a Tapered Resistive Strip Grating with Zero Resistivity at the Strip-Edges On a Grounded Dielectric Plane (접지된 유전체층 위에 저항띠 양끝에서 0으로 변하는 저항율을 갖는 저항띠 격자구조에서의 전자파 산란 해석)

  • 정오현;윤의중;양승인
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.11A
    • /
    • pp.883-890
    • /
    • 2003
  • In this paper, Electromagnetic scattering problems by a resistive strip grating with tapered resistivity on a grounded dielectric plane according as strip width and spacing, relative permittivity and thickness of dielectric layers, and incident angles of a electric wave are analyzed by applying the FGMM(Fourier-Galerkin Moment Method) Known as a numerical procedure. The scattered electromagnetic fields are expanded in a series of floguet mode functions. The boundary conditions are applied to obtain the unknown field coefficients and the resistive boundary condition is used for the relationship between the tangential electric field and the electric current density on the strip. The tapered resistivity of resistive strips varies zero resistivity at strip edges. Then the induced surface current density on the resistive strip is expanded in a series of Chebyshev polynomials of the second kind. The numerical results of the geometrically in this paper are compared with those for the existing uniform resistivity and perfectly conducting strip. The numerical results of the normalized reflected power for conductive strips case with zero resistivity in this paper show in good agreement with those of existing paper.

Analysis of Electromagnetic Scattering by Resistive Strip Grating with Zero Resistivity at the Strip-Edges On a Grounded 2 Dielectric Layers (접지된 2개의 유전층위에 저항띠 양끝에서 0으로 변하는 저항띠 격자구조에서의 전자파산란 해석)

  • Yoon, Uei-Joong
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.2
    • /
    • pp.152-158
    • /
    • 2006
  • In this paper, electromagnetic scattering problems by a resistive strip grating with zero resistivity at the strip-edges on a grounded 2 dielectric layers according as strip width and spacing, relative permittivity, thickness of dielectric layers, and incident angles of a electric wave are analyzed by applying the FGMM(Fourier-Galerkin Moment Method) known as a numerical procedure. The scattered electromagnetic fields are expanded in a series of floguet mode functions. The boundary conditions are applied to obtain the unknown field coefficients and the resistive boundary condition is used for the relationship between the tangential electric field and the electric current density on the strip. The tapered resistivity of resistive strips varies zero resistivity at strip edges. Then the induced surface current density on the resistive strip is expanded in a series of Chebyshev polynomials of the second kind. The normalized reflected power with zero resistivity in this paper show in good agreement with those of existing paper.

  • PDF