• Title/Summary/Keyword: 비틂전단시험

Search Result 27, Processing Time 0.028 seconds

Evaluation of Shear Wave Velocity of Engineering Fill by Resonant Column and Torsional Shear Tests (공진주와 비틂전단시험에 의한 성토지반의 전단파속도 추정에 관한 연구)

  • Park, Jong-Bae;Sim, Young-Jong;Jung, Jong-Suk;Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.2 no.4
    • /
    • pp.387-395
    • /
    • 2011
  • According to the seismic design criteria for structural buildings in Korea, the ground is classified into 5 types based on the average shear wave velocity measured from elastic wave tests on site and seismic load applied to the structure is estimated. However, elastic wave tests in site, however, on the engineering fill, cannot be performed during the construction period. Therefore, to evaluate shear wave velocity considering field conditions, resonant column (RC) and torsional shear (TS) tests are performed and compared with various elastic wave test results. As a result, if confining pressure for the tests using engineering fill are considered properly, we can obtain similar results comparing with those of elastic wave tests. In addition, by considering the effect of maximum shear modulus and confining pressure by RC/TS tests, n values shows typical values ranging from 0.434 to 0.561 so that utilization of RC/TS tests can be useful to infer shear modulus in field.

Development of Torsional Shear Testing System to Measure P-wave Velocity, S-wave Velocity and Pore Water Pressure Buildup on Fully and Partially Saturated Sands (포화 및 부분 포화 사질토의 Vp와 Vs 속도 및 과잉간극수압 측정을 위한 비틂전단 시험기의 개발)

  • Kim, Dong-Soo;Lee, Sei-Hyun;Choo, Yun-Wook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.1
    • /
    • pp.55-66
    • /
    • 2006
  • Laboratory tests have revealed that the liquefaction resistance of sands depends strongly upon the degree of saturation, which is expressed in terms of the pore pressure coefficient, B. The velocity of compression waves(i.e. P-waves), which have been known to be influenced largely by the degree of saturation and can be measured conveniently in the field, appears as an indicator of saturation. In this paper, the Stokoe type torsional shear(TS) testing equipment is modified to saturate the specimen and measure the velocities of P-wave and S-wave and pore pressure buildup. The velocities of P-wave and S-wave for Toyoura sand from Japan is measured and compared at the various B-value (degree of saturation) which are partially saturated to fully saturated conditions. Additionally, the variation of the pore water pressure induced during undrained TS tests at the various B-value is measured and analyzed.

  • PDF

Dynamic Deformation Characteristics of Granite Weathered Soils Using RC/TS Tests (공진주/비틂전단시험을 이용한 화강풍화지반의 동적변형특성)

  • Kim, Dong-Soo;Ko, Dong-Hee;Youn, Jun-Ung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.1
    • /
    • pp.35-46
    • /
    • 2004
  • In Korea, around one - third of the country is occupied by granite, and granite weathered soils are widely distributed. Most of the research on this soil has been performed using reconstituted specimens because of the extreme difficulty of undisturbed sampling due to the sensitive particle structures. Therefore, the comparisons of deformational characteristics, which is expressed in terms of shear and Young's moduli and damping ratio, obtained from the undisturbed and reconstituted specimens are important for the reliable understanding of soil behavior. In this study, the resonant column and torsional shear tests were performed on granite weathered soils in Korea, and the deformation characteristics of undisturbed and reconstituted soil on granite weathered soils were evaluated and compared.

  • PDF

Modifications of RC/TS(Resonant Column and Torsional Shear) Device for the Large Strain (대변형율 시험을 위한 공진주 비틂전단 시험기의 수정)

  • Bae, Yoon-Shin
    • International Journal of Highway Engineering
    • /
    • v.10 no.3
    • /
    • pp.1-10
    • /
    • 2008
  • Conventional RC/TS(resonant column and torsional shear) device usesa specimen with an aspect ratio(height-to-diameter) of 2:1 and this generates a maximum shear strain in the sample of about 1.5% at the maximum rotation of the drives system. The objective of this study is to modify RC/TS device to generate higher strain amplitude. The modifications include a new base pedestal to overcome the limitations in the travel of the drive system and modification of coil wiring to increase torque. The effects of the new coil wire on torque in the electro magnetic drive system were evaluated and the application of modified device was illustrated using sand soil.

  • PDF

A Solution to Large Strain Resonant Column and Torsional Shear Tests Apparatus (대변형율 시험을 위한 공진주/비틂전단 시험기의 해결방안)

  • Bae, Yoon-Shin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3C
    • /
    • pp.103-108
    • /
    • 2011
  • In this study, the limitations of large strain resonant column and torsional shear tests apparatus are described and solutions to the limitations are also described. The limitations are rotational distance, limited torque, and measurable deformation system, respectively. To resolve the rotational distance, the bottom platen was modified. And the four-armed drive plate was modified into eight-armed drive plate and the drive coil connection was changed to obtain powerful torque.

Evaluation of Seismic Response Characteristics of Hong-Seong Area based on In-Situ and Laboratory Tests (현장 및 실내시험에 기초한 홍성지역 지진응답특성 평가)

  • 박덕근;김교원
    • The Journal of Engineering Geology
    • /
    • v.11 no.1
    • /
    • pp.25-35
    • /
    • 2001
  • For the ground resrxmse analysis, both in-situ and laboratory testing techniques such as downhole, SASW, resonant column and torsional shear tests were perlormed for Hong-Seong area. The grOlmd upper 30m is classified as SD since it has an average shear wave velocity as 209m/s. The response specLrums obtained by site-specific analyses generally satisfied the seismic code, but near the resonance period the motion was evaluated to be higher than the code.

  • PDF

Measurement of $G_{max}$ of Sands Using Bender Element in Resonant Column and Torsional Shear Equipment (공진주/비틂전단 시험 및 벤더엘리먼트 시험을 이용한 사질토 지반의 최대전단탄성계수 평가)

  • Kim Dong-Soo;Youn Jun-Ung;Lee Sei-Hyun;Choo Yun-Wook
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.10
    • /
    • pp.17-25
    • /
    • 2005
  • The bender element method is an experimental technique to determine very small strain ($<10^{-3}\%$), elastic shear modulus of a soil, $G_{max}$ by measuring the velocity of shear wave propagation through a sample. Bender elements have been applied as versatile transducers to measure small strain modulus of wet or dry soils in various laboratory apparatus. In this paper, bender element (BE), resonant column (RC) and torsional shear (TS) tests were performed on Toyoura sand at various testing conditions using the modified Stokoe type RC/TS testing equipment capable of performing BE test. Based on the results, applicabilities of the testing method using bender element were evaluated by comparing the values of $G_{max}$ obtained from RC/TS and BE testing methods. For more dependable evaluation, the loading frequency of each testing method was considered for the results obtained for samples in saturated condition by adapting Biot's theory.

Dynamic Deformation Characteristics of Sands Under Various Drainage Conditions (배추 조건에 따른 사질토 지반의 동적 변형특성)

  • Choo Yun-Wook;Kim Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.3
    • /
    • pp.27-42
    • /
    • 2005
  • In this study, dynamic deformation characteristics of sands under dry, saturated drained and undrained conditions were investigated at small to intermediate strains using the modified Stokoe-type torsional shear tests. The equipment was modified to saturate the specimen and to maintain the B-value above 0.99 during the test. On two types of sands, Geumgang sand from Korea and Toyoura sand from Japan, tests were carried out at various drainage conditions, void ratios, and effective confining pressures. Based on the test results, dynamic deformation characteristics, shear modulus (G) and damping ratio (D), and/or pore-water pressure were measured with strain amplitude and number of loading cycles. Variations of G and D at small ($\gamma_c<{10}^{-3}\%$) to medium (${10}^{-3}\%<\gamma_c<{10}^{-1}\%$) strains were measured under various drainage conditions, and test results were intensively compared considering drainage conditions.

An Anisotropic Hardening Elasto-Plastic Constitutive Model for the Behavior at Small-to-Large Strain Conditions (미소변형률 및 대변형률 조건의 거동에 대한 비등방경화 탄소성 구성모델)

  • 오세붕;권기철;정순용;김동수
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.65-73
    • /
    • 2000
  • An elasto-plastic constitutive model was proposed, in which the behavior at small-to-large strain level can be modeled. The proposed model is based on the anisotropic hardening description with the generalization of isotropic hardening rule and the total stress concept. From a mathematical approach it was proved that the model includes the previous successful models. The model was verified by a series of resonant column tests, torsional shear tests and triaxial tests, and the proposed model predicted small-to-large strain behavior more consistently and accurately than the hyperbolic model and the Ramberg-Osgood model for a weathered granitic soil. In addition, the nonlinearity under small strain condition was predicted appropriately for the torsional shear test results.

  • PDF

Evaluation of Applicability of HMS-25 as the Railroad Roadbed Material (철도 노반재로서의 수경성 입도 조정 고로슬래그(HMS-25)의 적용성 평가)

  • 황선근;이성혁;이시한;최찬용
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.157-165
    • /
    • 2000
  • The applicability and performance of HMS-25 as the railroad roadbed materials were evaluated through the model and laboratory tests. The uniaxial compression test of HMS-25, model soil box test, and combined resonant column and torsional shear test were performed for static and dynamic analysis of railroad roadbed. The uniaxial compression test result of HMS-25 shows steady increase in strength due to hardening chemical reaction between HMS-25 and water. The result of model soil box test reveals that railroad roadbed of HMS-25 is better than that of soil in several aspects such as bearing capacity and settlement. The combined resonant column and torsional that shear test result indicates that shear modulus of HMS-25 increases with the power of 0.5 to the confining pressure and that shear modulus increases with the increase of curing period.

  • PDF