• Title/Summary/Keyword: 비율단가

Search Result 70, Processing Time 0.029 seconds

Conceptual Cost Estimation Model Using by a Parametric Method for High-speed Railroad (매개변수기법을 이용한 고속철도 노반공사의 개략공사비 예측모델)

  • Lee, Young Joo;Jang, Seong Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4D
    • /
    • pp.595-601
    • /
    • 2011
  • There is currently applied to the unit cost per a distance (KRW/km) for estimating the conceptual cost of civil work on basic planning stage of high speed railroad. This unit cost is an arithmetic average value based on historical data, which could be in big error. It also is difficult to explain the deficiency comparing the estimated cost derived from next basic design stage. This study provides the conceptual estimation model using by the parametric method and regression analysis. Independent variables are the distance and the geological materials (earth, weathered rock, soft-rock, hard-rock), extracting from the actual data to 36 contracts. The deviation between the unit costs estimated using the developed model and the actual cost data is presented in the range from -0.4% to +31%. This range is acceptable compared the typical range "-30% to + 50%". This model will improve the accuracy of existing method and be expected to contribute to effective total cost management and the economic aspects, reduce the financial expenditure.

DC 반응성 스퍼터링법으로 증착한 TiN/Al, TiCN/Al 박막의 전기적.기계적 특성 및 내부식성 평가

  • Lee, Hyeon-Jun;Song, Pung-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.346-347
    • /
    • 2012
  • 최근 화석연료 대체 에너지원으로서 자동차용으로 연구 개발 및 응용되고 있는 고분자 전해질 연료전지(PEMFC: Proton exchange membrane fuel cells)에서 분리판(Bipolar Plate)은 스택 전체 무게의 80%, 스택 가격의 60% 정도로 가장 높은 비중을 차지한다. 분리판은 연료와 산화제를 공급해주는 통로 및 전지 운전 중에 생성된 물을 제거하는 통로 역할과 anode, cathode로서 전극 역할을 통해 스택 전력을 형성하는 핵심 기능과 전지와 전지 사이의 지지대 역할을 한다. 따라서 분리판은 전기전도성, 내부식성 및 기계적 특성이 우수해야함은 물론이고, 얇고 가벼우며 가공성이 뛰어나야 한다. 현재 가장 많이 사용되고 있는 금속 분리판 소재 중 스테인리스 스틸은 전기적, 기계적 특성 및 내부식성이 우수한 반면, 가격이 비싸고, 중량이 무거운 단점이 있다. 따라서 본 연구에서는 DC 반응성 마그네트론 스퍼터링법으로 전기적, 기계적 특성 및 내부 식성이 우수한 TiN, TiCN 박막을 스테인리스에 비해 중량이 1/3, 소재 단가가 1/4인 알루미늄 기판 위에 증착하여 박막 물성을 평가하였다. DC Power는 400 W, 기판과 타겟 사이의 거리는100 mm, 공정 압력은 0.5 Pa로 고정하였고, 3 inch의 지름과 순도 99.95%를 갖는 티타늄 타겟을 사용하였다. 공정 가스는 Ar을 주입하였으며, 질소와 탄소의 공급원으로는 질소($N_2$)와 메탄($CH_4$) 가스를 사용하여 챔버 내 주입혼합가스의 전체 유량을 50 sccm으로 고정시켰다. 증착된 박막의 전기적, 기계적 특성을 측정하였고, X-ray diffraction (XRD), Scanning electron microscope (SEM)을 이용하여 박막의 미세구조 및 표면 상태를 확인하였다. 또한, 내부식 특성을 평가하기 위해 potentiostatic, potentiodynamic 법을 이용하여 박막의 부식저항을 측정하였다. 증착된 TiN 박막의 경우 질소 함량의 증가에 따라 박막 증착속도는 감소하는 경향을 보였다. 이는 타겟 부근의 질소 라디칼 비율이 증가함에 따라 질화반응이 촉진된 것으로 생각된다. 또한, 증착된 TiN과 TiCN 박막은 반응성 질소 유량과 탄소 유량에 따라 각각 다른 미세구조를 가지는 것을 확인하였다. TiN과 TiCN은 NaCl형의 면심입방격자(FCC)로 같은 구조이며, 격자상수가 비슷하여 전율고용되어 TiCN을 형성하고, 탄소와 질소의 비에 따라 전기적 기계적 특성이 달라짐을 확인하였다.

  • PDF

An Economic Evaluation of MSW RDF production plant (생활폐기물고형연료(RDF) 제조기술 경제성 평가)

  • Choi, Yeonseok;Choi, Hangseok;Kim, Seockjoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.158.1-158.1
    • /
    • 2010
  • 국내 최초의 생활폐기물고형연료(RDF) 생산플랜트인 원주시 RDF플랜트의 2009년도 운영실적을 정리하여 폐기물 처리단가를 분석하였으며 에너지 생산 효과도 분석하였다. 실적분석에 사용된 자료는 원주 RDF플랜트 위탁운영업체가 운영비를 청구 및 정산하기 위해서 원주시에 상시 측정 및 보고하는 항목으로서, 내용은 트럭으로 플랜트에 반입되는 폐기물 전체량, RDF생산 전체량, 불순물 매립 전체량, 건조 및 탈취용 연료사용 전체량, 전기사용 전체량 등이다. 2009년도 원주시 RDF플랜트에 반입된 폐기물 량은 총 17,504톤이었고, RDF를 총 7,044톤 생산하였으며, 4,120톤의 불연물을 선별하였다. 1년간 사용한 건조 및 탈취용 연료는 총 596,268 리터였으며 연료인 부생유의 가격은 리터 당 평균 864.6원이었다. 사용한 전기량은 총 2,435,397 kWh였고, 이 중에서 성형공정에 사용된 전기량은 총 사용량의 19%였다. 이상의 기록자료들을 분석해 본 결과, 폐기물 1톤을 처리하는데 전기 비용이 14,334원이었고, 연료비가 29,452원이었다. 여기에 폐기물 1톤당 불연물 매립비 6,573원과 위탁인건비를 합하면 폐기물 1톤당 처리비용은 약 116,573원으로 나타났다. 현재 원주시 RDF는 톤당 25,000원에 판매되고 있으므로 이 비용을 감안하면 폐기물 1톤당 처리비용은 105,298원으로 산출되었다. 현재 알려진 유사 규모의 소각로 운영비가 폐기물 1톤당 136,736원인데, 이것은 RDF기술보다 31,438원/톤-폐기물 정도 처리비용이 비싸다. 따라서 100톤 이하 규모의 폐기물처리시설 설치를 할 경우에는 RDF 시설이 경제적으로 타당함을 나타낸다. 원주시 RDF플랜트의 물질수지를 분석해 본 결과, RDF생산 수율은 40.2%였으며 총 투입된 에너지는 8,0587 Gcal였다. 생산된 에너지 총량은 RDF발열량 4,500 kcal/kg으로 했을 때 31,699 Gcal로 나타났다. 투입대비 생산에너지 비율은 25.4%로 계산되었고, 전기의 발전효율을 40%로 감안했을 경우에는 35.3%로 계산되었다. 성형하는데 사용되는 총 에너지는 전체 투입에너지의 4.9%로 나타났고, 비용으로는 폐기물 1톤당 2,723원 이었다.

  • PDF

The Mean Formula of Implicate Quantity (내포량의 평균 공식과 조작적 학습법)

  • Kim, Myung-Woon
    • Journal for History of Mathematics
    • /
    • v.23 no.3
    • /
    • pp.121-140
    • /
    • 2010
  • This study presents one universal mean formula of implicate quantity for speed, temperature, consistency, density, unit cost, and the national income per person in order to avoid the inconvenience of applying different formulas for each one of them. This work is done by using the principle of lever and was led to the formula of two implicate quantity, $M=\frac{x_1f_1+x_2f_2}{f_1+f_2}$, and to help the understanding of relationships in this formula. The value of ratio of fraction cannot be added but it shows that it can be calculated depending on the size of the ratio. It is intended to solve multiple additions with one formula which is the expansion of the mean formula of implicate quantity. $M=\frac{x_1f_1+x_2f_2+{\cdots}+x_nf_n}{N}$, where $f_1+f_2+{\cdots}+f_n=N$. For this reason, this mean formula will be able to help in physics as well as many other different fields in solving complication of structures.

Assessment of Customer Interruption Cost by Regional Groups for Macro Approach (거시적 방법을 이용한 지역별 정전비용 평가)

  • Park, Choong-Yeul;Huh, Chang-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.124-129
    • /
    • 2005
  • Reliability of electric power supply by power system becomes major issue as the electric power industry is recently being regulated. Also a change of environmental condition related to power supply reliability should be considered in the view of power supplier since the competition between energy-industries is strengthen. In other words, because customers may choose other energy source instead of electric power due to an expensive energy charge, enhancing recklessly the reliability of power supply might not be an essential strategy. So to effectively cope with this problem, it is necessary to perceive the reaction of customers against power supply reliability and interruption cost. This paper evaluates the annual interruption costs of customers by regional groups in Korea using a macro approach to cope with these internal and external environment. That is, the each ratio of customer's interruption costs to price of electric power charge is evaluated for public, service, agricultural, fishery, mining, manufactural, and residential consumption by every cities and provinces.

Analysis on Characteristic of Construction Cost for Steel Box Bridge (강박스교량 공사비 특성 분석)

  • Sun, Chang Won;Kyung, Kab Soo;Kang, Shin Hwa;Kwon, Soon Cheol
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2009
  • Estimating appropriate construction cost at the design phase is judged with one important issue to the efficient security and the execution of budget. Therefore, in this paper, to build fundamental data of appropriate construction cost for steel box bridges, the existing calculated document such as the quantity, unit price document and detail items etc.. was analyzed and the basic specification of the bridges was investigated. Also, by estimating the relationship between predetermined cost and construction items on the bridges, the paper is intended to produce basic data for the calculation of appropriate construction cost in planning phase. From the result, it was calculated ratio of construction item in the total construction cost and unit cost. And then it was deduced effect factor of construction cost in steel box bridge.

Improvement of CSVR used for Flood Damage Estimation based on Insurance Claim DB (침수피해액 추정을 위한 CSVR의 보험 Claim DB 기반 개선)

  • Baek, Chun Woo;Roh, Jin Yong;Lee, You Me;Park, Hong Gyu;Bae, Young Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.193-193
    • /
    • 2019
  • 기후변화로 인한 거대 자연재해 발생의 위험이 지속적으로 증가하고 있으며, 국외의 경우 주요정부기관, 보험사 및 연구기관 중심으로 자연재해 피해예측 모델을 개발하여 사용하고 있다. 침수사고 인한 피해는 건물은 물론이고 가재도구, 재고자산, 기계시설 등의 내용물에서도 발생하며, 건축물 신축단가 등을 이용해 비교적 쉽게 자산가치를 산정할 수 있는 건물구조물과 다르게, 건물내용물의 자산가치는 시설물의 업종, 용도, 사용자 특성 등에 따라 변동성이 큰 특징이 있다. 내용물의 피해액 추정을 위해 자연재해 피해예측 모델은 건물 구조물과 내용물 가치의 비율인 CSVR(Contents to Structure Value Ratio)을 사용하며, CSVR은 시설물 용도에 따른 자산가치평가 통계를 이용해 산정할 수 있다. 충분한 자산가치평가 DB를 확보할 경우 CSVR의 정확도 확보가 가능할 것이며, 이를 위해 국내에서는 민간보험사의 재물보험 계약 4만여건의 건물, 내용물 보험가입금액을 행정안전부 도로명전자지도에서 분류하는 건물 용도에 따라 분석한 연구결과가 있다. 하지만, 일반적으로 보험가입단계에서 대략적으로 추정하는 보험가입금액과 실제 자산의 가치는 차이가 있을 수 있지만, 보험가입물건의 실제 자산가치는 일부만 DB화 되어 있는 단점이 있다. 본 연구에서는 사고 발생 후 작성되는 손해사정보고서에서 평가한 정확한 자산가치 DB를 수집하여, 보험가입금액을 기준으로 산정한 CSVR의 결과와 비교하였다. 손해사정보고서에서 평가한 실제 자산가치를 기준으로 분석한 CSVR과 보험가입금액을 기준으로 산정한 CSVR은, 업종에 따라 유사하거나 큰 차이를 보이는 경우도 있었으며, 침수로 인한 정확한 피해액 추정을 위해서는 보다 양질의 DB확보를 통한 CSVR의 정확도 확보가 필요한 것으로 분석되었다.

  • PDF

Estimation of Advertising Exposure Distribution by Zero-inflation Regression Models (영과잉 회귀모형을 이용한 광고노출분포 추정)

  • Lee, Dong-Hee
    • Journal of the Korean Data Analysis Society
    • /
    • v.20 no.6
    • /
    • pp.2841-2852
    • /
    • 2018
  • This study examines regression modeling method using zero-inflated distribution in relation to estimation of exposure distribution required in advertisement media planning. Exposure distribution is the percentage of audiences that are exposed each time the ad is repeated. Such an exposure distribution plays a very important role in providing basic information necessary for calculating various indicators for quantitatively measuring the advertising effect. Especially, due to the decrease of advertising price and the spread of various media, the frequency of the advertisement or the broadcasting of specific advertisements has been greatly increased compared to the past. As a result, the frequency of exposure is relatively decreasing. In this situation, the number of individuals who are not exposed to the media, that is, are not exposed to advertising structurally is increasing. This research proposes advertising exposure distribution models using a zero-inflated regression model, and conducts a comparative study using actual cases.

Assessing Possible Tax Plans on Nuclear Electricity Generation in Korea (원자력 발전에 대한 과세방안 연구)

  • Sunghoon Hong
    • Environmental and Resource Economics Review
    • /
    • v.31 no.4
    • /
    • pp.711-731
    • /
    • 2022
  • In Korea, nuclear power plants are major sources of electricity supply with relatively low costs. Despite the importance and scale of nuclear electricity generation, the Korean tax and levy system is less organized than those in other countries, such as France and Japan, where nuclear power plants also play significant roles for electricity supply. Countries impose tax on nuclear electricity generation roughly in three ways: tax on nuclear reactors; tax on uranium fuel; tax on electricity from nuclear power plants. The Korean government may consider taxing nuclear electricity generation based on uranium fuel or electricity generation. If taxing on uranium fuel at the rate of 90 KRW per milligram of uranium, the Korean government can collect additional tax revenue of 430 billion KRW. If taxing on electricity from nuclear power plants at the rate of 11 KRW per kilowatt-hour, the government can collect additional tax revenue of 1,600 billion KRW.

Changes of Physicochemical Properties of Paper Mill Sludge and Sewage Sludge Mixed with Various Ratios of a Bulking Agent During Composting (공극개선재의 혼합비율에 따른 제지·하수슬러지의 퇴비화과정중 이화학성 변화)

  • Yu, Young-Suk;Chang, Ki-Woon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.6 no.2
    • /
    • pp.45-57
    • /
    • 1998
  • The object of this experiment was to determine the optimum mixing ratio of paper mill sludge and sewage sludge with woodchips as a bulking agent. The bulking agent was mixed with the mixture of paper mill sludge and sewage sludge(2:1 by dried weight) at the rates of 0(W-0), 20(W-20), 33(W-33), and 50(W-50)% on volume basis, and then the mixtures were composted by forced aerated static pile. The changes of physicochemical properties of the mixtures were measured during the composting in order to evaluate the maturity of composts. The temperatures of W-30 and W-50 treatments increased rapidly as soon as the composting started, and reached $60^{\circ}C$ in the fifth day of composting. Reduction of hot water soluble C/N ratio of W-33 and W-50 treatments showed faster than that of W-0 and W-20 treatments at early stage of the composting. The contents of hot water soluble $NO_3{^-}-N$ showed little change in the early stage of the composting in all treatments, but increased rapidly after 20 days of the composting, and the contents of W-0 among all treatments were lower than the others. The G.I. values of W-50 treatment were over 80 before 20 days after starting the composting, those of W-0 treatment were over 80 after 30 days. As a result of evaluation of compost, W-33 and W-50 treatments were found very reasonable at the mixing ratio of a bulking agent. But it is very difficult to aerate compost pile for W-50 treatment than W-33 treatment due to intensified fluctuation of temperature. Considering cost, availability of a bulking agent, and productivity of compost, W-33 treatments more efficient than W-50 treatment.

  • PDF