• Title/Summary/Keyword: 분석법

Search Result 26,356, Processing Time 0.053 seconds

Optimization Study of Trace Analysis of Potential Diesel Oxygenate Using the Design Of Experiment (DOE) in Solid-Phase Microextraction with GC/FID (고체상미량분석법(SPME-GC/FID)에서 실험계획법을 이용한 디젤첨가제 미량분석의 최적화 연구)

  • Park, Jae-Sang;Chang, Soon-Woong
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.5
    • /
    • pp.73-85
    • /
    • 2007
  • In this study, the experiment of solid-phase microextraction (SPME) technique using GC/FID was conducted as a possible alternative to liquid-liquid extraction for the analysis of EGBE, DGBE, DBM and TGME in water, and also, an optimization condition of trace analysis for disel oxygenates including EGBE by the design of experiment (DOE) was described. Experiments used a fractional factorial design method followed by central composite design allowing optimization of a number of factors as well as statistical analysis of the results. The response surface analysis showed that the extraction efficiency could be represented by a second-order polynomial equation in which the salts concentration, extraction temperature, extraction time and sonication time are the major influences. Using DOE method, a new datadependent method was developed to improve the quantity of confidently analyzed disel oxygenates in water samples.

A Study on the Perception of Data 3 Act through Big Data Analysis (빅데이터 분석을 통한 데이터 3법 인식에 관한 연구)

  • Oh, Jungjoo;Lee, Hwansoo
    • Convergence Security Journal
    • /
    • v.21 no.2
    • /
    • pp.19-28
    • /
    • 2021
  • Korea is promoting a digital new deal policy for the digital transformation and innovation accelerating of the industry. However, because of the strict existing data-related laws, there are still restrictions on the industry's use of data for the digital new deal policy. In order to solve this issue, a revised bill of the Data 3 Act has been proposed, but there is still insufficient discussion on how it will actually affect the activation of data use in the industry. Therefore, this study aims to analyze the perception of public opinion on the Data 3 Act and the implications of the revision of the Data 3 Act. To this end, the revision of the Data 3 Act and related research trends were analyzed, and the perception of the Data 3 Act was analyzed using a big data analysis technique. According to the analysis results, while promoting the vitalization of the data industry in line with the purpose of the revision, the Data 3 Act has a concern that it focuses on specific industries. The results of this study are meaningful in providing implications for future improvement plans by analyzing online perceptions of the industrial impact of the Data 3 Act in the early stages of implementation through big data analysis.

Comparison of the Methods to Analyze Freshwater Sediments (담수 퇴적물의 분석법간 비교 분석)

  • Yoon, Byeng-Seok;Kim, Eun-Mi;Kim, Hak-Chul;Lee, Jae-Hee;Jung, Sang-Gi;Lee, Sang-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.11
    • /
    • pp.1207-1212
    • /
    • 2006
  • In this study, Chemical Oxygen Demand(COD) which is the measure of organic substances, Total nitrogen(T-N), Total phosphorous(T-P), Fe and Mn were analyzed in the sediments of dam reservoir. The purpose of this study were to understand the relevances among the analytical methods adopted and the applicabilities of those methods. For the determination of COD, Standard Method for the Examination of Marine Environment(SMEME) and Standard Method for the Examination of Sanitary(SMES) was used. Both method had wide dynamic range and the deviations of the values obtained by two methods were small because $KMnO_4$ method closely reflected BOD and organic substances. For the determination of T-N and T-P, Standard Method for the Examination of Food(SMEF) and Standard Method for the Examination of Sanitary(SMES) were used. Two methods for T-N were both the acid-base titration but SMES gave less T-N values than SMEF because of the differences in digestion and distillation steps. Two methods for T-P gave the comparable values after acid digestion of $HNO_3$ and $HClO_4$. The determination of heavy metals as a Fe, Mn was mainly divided to the leaching method and acid digestion method. The values obtained by leaching method were less than those by digestion method. It is thought that the condition of acid digestion was more severe than that of leaching method.

Development of Rapid Analytical Method for Heavy Metals (Cd, Pb) in Meju using fs LA-ICP-MS (fs LA-ICP-MS를 이용한 메주의 유해중금속(Cd, Pb) 신속 분석법 개발)

  • Shin, Hee-Chang;Choi, Ji-Hye;Kim, Yong-Kyoung;Kim, Dae-Jung;An, Jae-Min;Kim, Sung-Youn
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.129-135
    • /
    • 2022
  • The official analytical method for the analysis of harmful heavy metals in Meju, distributed in Korea, employs a strong acid to decompose the organic components. This analysis is time consuming and harmful to the users and/or the environment. This study aimed to develop a new pre-treatment technology using laser ablation, to rapidly analyze harmful heavy metals without using strong acids. The results obtained from this method were validated by the National Institute of Food and Drug Safety Evaluation guideline (NIFDS, 2016). Moreover, a comparison of the two methods showed that the analytical time for 55 Meju samples was shortened by 96% or more in the new method. The results showed no significant difference in the recovery ranging from 90-120%. The proposed method proved suitable for detecting harmful heavy metals in Meju.

Analysis of Worst-Case Response Time for Backplane Bus Network (백플레인 버스 네트워크를 위한 최악 응답 시간 분석)

  • Seong, Min-Yeong;Jang, Rae-Hyeok;Sin, Hyeon-Sik
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.28 no.1_2
    • /
    • pp.11-19
    • /
    • 2001
  • 근래에 들어, 백플레인 버스를 기반으로 하는 멀티프로세서 시스템의 프로세서간 통신에도 TCP/IP와 같은 표준 네트워크 프로토콜을 이용하여 표준 MAC 계층을 구현하는 것이 일반적이다. 본 논문은 이러한 MAC 에뮬레이션 기반 버스 네트워크상에서 내장형 실시간 은용을 지원하기 위한 최악 응답 시간 분석법을 제시한다. 본 논문의 분석법은 구체적으로 MAC 에뮬레이션 방법의 하나인 ANSI BusNet 프로토콜을 대상으로 진행된다. 각 실시간 태스크를 주기, CPU 시간, 종료시한, 메시지 패킷 개수로 모델링하고 스케쥴 가능성, 즉 주어진 종료 시한 내에 작업을 완료할 수 있는지의 여부를 검사하는 수식을 유도한다. 이를 위해 물리적인 버스 특성을 고려한 버스 전송 모델을 제시하고, 버스 중재 방식과 버스 하드웨어의 캐슁 지원 여부에 따른 스케쥴 가능성을 분석한다. 또한 본 논문에서는 실험을 통해 블록 전송이 실시간 통신 성능에 미치는 영향을 살펴본다. 비록 본 논문의 분석법이 BusNet에 기반하여 개발되었지만, BusNet이 대부분의 백플레인 하드웨어가 지원하는 기본적인 기능만을 가정하고 있으므로, 본 논문의 분석법은 다른 종류의 백플레인 네트워크 프로토콜에도 쉽게 적용될 수 있다.

  • PDF

Validation of an analytical method of oxyresveratrol for standardization of Mulberry (Morus alba L.) branch extract as a functional ingredient (상지추출물의 기능성원료 표준화를 위한 지표성분 옥시레스베라트롤 분석법 검증)

  • Jeon, Young-Hee;Choi, Sang-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.50 no.4
    • /
    • pp.377-382
    • /
    • 2018
  • An HPLC method was developed to quantitate a marker, oxyresveratrol (ORT), for the standardization of mulberry branch extracts (MBE) as a functional ingredient. HPLC was performed on a $C_{18}$ column with a gradient elution using 0.05% $H_3PO_4$ and acetonitrile at a flow rate of 0.8 mL/min, and detected at 320 nm. The HPLC method was validated according to Korea Food and Drug Administration (KFDA) guideline of analytical procedures with respect to specificity, linearity, accuracy and precision. Calibration curve of ORT showed high linearity ($R^2=1$), and limits of detection and quantification were 0.3 and $1.0{\mu}g/mL$, respectively. Relative standard deviation values from intra-and inter-day precision were less than 3.52 and 4.70%, respectively. Recovery rate ranged from 97.64% to 103.69%, and ORT content in MBE was approximately 3.78%. These results suggest that the HPLC method developed for the analysis of ORT in MBE is simple, efficient, and could contribute to the quality control of MBE.

Face Recognition by Combining Linear Discriminant Analysis and Radial Basis Function Network Classifiers (선형판별법과 레이디얼 기저함수 신경망 결합에 의한 얼굴인식)

  • Oh Byung-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.6
    • /
    • pp.41-48
    • /
    • 2005
  • This paper presents a face recognition method based on the combination of well-known statistical representations of Principal Component Analysis(PCA), and Linear Discriminant Analysis(LDA) with Radial Basis Function Networks. The original face image is first processed by PCA to reduce the dimension, and thereby avoid the singularity of the within-class scatter matrix in LDA calculation. The result of PCA process is applied to LDA classifier. In the second approach, the LDA process Produce a discriminational features of the face image, which is taken as the input of the Radial Basis Function Network(RBFN). The proposed approaches has been tested on the ORL face database. The experimental results have been demonstrated, and the recognition rate of more than 93.5% has been achieved.

  • PDF

Evaluation of Dry Rehydratable Film Method for Enumeration of Microorganisms in Korean Traditional Foods (한국 전통식품 중 미생물 분석을 위한 건조필름법 평가)

  • Kim Kwan-Sik;Bae Eun-Kyung;Ha Sang Do;Park Young Seo;Mok Chul Kyoon;Hong Kwan Pyo;Kim Sang Phil;Park Jiyong
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.4
    • /
    • pp.209-216
    • /
    • 2004
  • Dry rehydratable film methods were compared to conventional methods for the enumeration of microorganisms in Korean traditional foods. Kimchi, doenjang, kochujang, kanjang, takju, sujeongkwa and sikhe were used as Korean traditional foods. $Petrifilm^{TM}$ aerobic count plate, $Petrifilm^{TM}$ coliform count plate, $Petrifilm^{TM}$ E. coli/coliform count plate, $Petrifilm^{TM}$ yeast and mold count plate and $Petrifilm^{TM}$ staph express count plate were compared to plate count agar, most probable number (MPN) for coliform, MPN for E. coli, potato dextrose agar and coagulase test, respectively. Regression analysis indicated that correlation coefficient values were 0.974-0.998, 0.913-0.995, 0.955-0.978, 0.968-0.986 and 0.998-0.999 for total aerobic bacteria, yeast and mold, coliform, E. coli and S. aureus, respectively. There were no significant differences between two methods, suggesting that $Petrifilm^{TM}$ plates can be used as an alternative to conventional method for the determination of microorganisms in Korean traditional foods.

Determination of trace actinide (Am, Pu, Th, U) using alpha spectrometry and neutron activation analysis (알파분광법과 중성자방사화분석법에 의한 극미량의 악티늄계원소 (Am, Pu, Th, U)분석연구)

  • Yoon, Yoon Yeol;Lee, Kil Yong;Cho, Soo Young;Kim, Yongjai;Lee, Myong Ho
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.302-307
    • /
    • 2004
  • Determination of actinides in the environmental sample requires separation of each element. This procedure is tedious and time consuming. And also, the detection limits of some nuclides using alpha spectrometry are rather higher. To overcome the lower detection limit and complicated separation procedure, a simple analytical technique for the determination of actinide isotopes in the environmental samples was developed and applied to IAEA and NIST reference sediment samples. For the separation of actinides from matrix, anion exchange resin and TRU-spec extraction chromatography resin were used and chemical yields were obtained using natural uranium, thorium, $^{242}Pu$ and $^{243}Am$ tracers. For overcoming the higher detection limits of U and Th in alpha spectrometry, neutron activation analysis was applied. Using combined method, the detection limit was increased about 10 times. The activity values of each isotope were consistent with the reference values reported by IAEA and NIST.

Determination of Polybrominated Diphenyl Ethers(PBDEs) in Soil using Gas Chromatography/Isotope Dilution Mass Spectrometry (기체크로마토그래피/동위원소 희석 질량분석법을 이용한 토양 중 폴리브롬화 디페닐에테르의 분석법)

  • Na, Yuncheol;Chang, Yoon-Seok;Kim, Hai-Dong;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • An analytical method of polybrominated diphenyl ethers in soil samples by isotope dilution method using gas chromatography/mass spectrometry (GC/MS)-selected ion monitoring (SIM) was described. PBDEs in soil were extracted with soxhlet extractor and then silica and florisil solid phase extraction (SPE) methods as purification of extract were compared. After clean-up, the extractions were analyzed by GC/MS with SIM mode. Quantitation was performed isotope dilution method using four $^{13}C$ isotopically labeled PBDEs as internal standards. This developed method was validated for eight congeners of PBDEs in the concentration range 0.04~4 ng/g in soil and the average recovery of the analytes ranged 30.8~110.8% for florisil and 44.4~110.7% for silica, respectively. The method detection limits of PBDEs were 0.04~0.3 ng/g.