• Title/Summary/Keyword: 분만 2기

Search Result 2,361, Processing Time 0.043 seconds

Studies on Degradation of Butachlor and Nitrofen in Different Soil Conditions (토양중(土壤中) Butachlor 와 Nitrofen의 분해(分解)에 관(關)한 연구(硏究))

  • Oh, Byung-Youl;Jeong, Young-Ho;Lee, Byung-Moo
    • Applied Biological Chemistry
    • /
    • v.24 no.2
    • /
    • pp.112-119
    • /
    • 1981
  • The persistence of preemergence herbicides, butachlor [2-chloro-2,6-diethyl-N(butoxymethyl) acetanilide] and nitrofen(2,4-dichlorophenyl-4-nitrophenyl ether), at 10 ppm level in different soil conditions amended with organic matter and lime was studied under flooded and field moisture capacity. The microbial breakdown played a major role in the dissipation of the herbicides in soil. Nitrofen degradation in flooded soil was greatly accelerated, while it was slowed down in field moisture capacity as compared with butachlor. Increased amendment of rice straw to the soil shortened the half-life of butachlor under flooded condition, however it prolonged that of butachlor when the amendment was exceeded over 1% on dry weight basis. Liming the soil stimulated decomposition of the herbicides in the soil systems, which ap pears to be pH independent.

  • PDF

Development of 2.5 Gbps Multi-Channel Tunable Wavelength Converter Based on Cross Gain Modulation in Semiconductor Optical Amplifier (반도체 광증폭기의 상호 이득 변조를 이용한 2.5 Gbps 다채널 가변형 파장변환기)

  • Son, Jung-Min;Lee, Sang-Sun
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.392-396
    • /
    • 2005
  • A new structure of tunable wavelength converter based on XCM in SOA was tried and analyzed. This converter used single SOA and had very simple structure. In this paper, results were experimentally obtained and demonstrated. Pump signal was generated with NRZ $(PRBS\;2^{31}-1)$ and data rate 2.5 Gbps. WDM multi conveted signals showed more than 8.3 dB extinction ratio. For BER performance, all these converted signals had within 5.0 dB power penalty compared with the pump signal. With these results, we showed that this converter was suitable for 2.5 Gbps WDM multi-channel wavelength converting.

A Study of Prehosptal Airway Devices Tested Using a Simulation Training (병원전 단계 기도기 시뮬레이션 교육에 대한 연구)

  • Cho, Byung-Jun;Kim, Jee-Hee;Moon, Tae-Young;Lee, Hyung-Ji;Park, Sung-Il
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05b
    • /
    • pp.1061-1063
    • /
    • 2011
  • 본 연구는 병원전 단계 기도기 시뮬레이션 교육에 대한 연구로 연구대상은 응급구조학과 4학년 학생 22명으로 구성하였다. 교육시간은 10분 동안 3개의 기도유지기에 대한 전체 강의가 있었고, 10분 동안 마네킹을 이용하여 세 가지 기도기의 사용방법을 교육하고 실습을 시행하였다. 응급구조학과 학생을 대상으로 Airway management trainer Simman를 이용한 기도 내 이물 제거 모델에서 매킨토시후두경과 GlideScope and the AWS$^{(R)}$, McGrath$^{(R)}$ 비디오 후두경의 기관내 삽관 성공률과 삽관 시간, 시행자의 선호도를 비교한 결과 의미 있는 차이를 보였다. 마네킨을 이용한 병원전 기도기인 1차 시도에서는 유의한 차이를 보였지만 2차에서 숙련이 된 경우이라서 큰차이를 보이지 않았다. 기관내 삽관 기구의 선호도 조사에서는 Pentax AWS를 가장 선호하였다.

  • PDF

Fair Relay Selection in Regenerative OFDMA Relay Network (재생 OFDMA 중계 네트워크에서의 공평한 중계기 선택)

  • Jeong, Ha-Rin;Kim, Jin-Su;Lee, Jae-Hong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.2
    • /
    • pp.11-17
    • /
    • 2009
  • This paper presents a new adaptive relay selection scheme for a regenerative orthogonal frequency division multiplexing access(OFDMA) relay network with fairness constrains. In the Proposed scheme, we select the best M relays out of a set of K potential relays to maximize system capacity. Among these selected relays, subcarriers are reallocated to satisfy fairness constraints as well as to minimize the degradation of the system performance. Afterwards, power allocation is performed for each subcarrier based on the water-filling method to enhance the performance improvement. By using the trade-off relationship between the system capacity and the fairness, the modified version of proposed scheme is also investigated.

Automatic Left Ventricle Segmentation on Cardiac Magnetic Resonance Image (심장 자기공명영상에서의 좌심실 자동 분할 알고리즘)

  • Jo, Hyun Wu;Lee, Hae-Yeoun
    • Annual Conference of KIPS
    • /
    • 2010.11a
    • /
    • pp.561-564
    • /
    • 2010
  • 의학과 기술 발달로 인해 질병과 사고에 의한 사망률은 줄어들었으나, 심장 관련 질환에 의한 사망률은 증가하였다. 심장 질환을 예방하는 데는 정기적인 검진을 통해 심장기능을 분석하고 관찰하는 것이 중요하다. 심장 기능의 분석은 이완기와 수축기 사이의 혈류량 및 심박구출률 계산을 통한 심장 운동능력 평가에 의해 이루어진다. 본 연구에서는 심장 단축 자기공명영상에서 좌심실 영역을 자동 분할하여 혈류량 및 심박 구출률을 계산하는 알고리즘을 제안한다. K평균 군집화 기법을 적용하여 좌심실을 분할하고, 그래프 탐색 기법에 기반하여 분할 오류를 수정하였다. 15명의 지원자에 대해 제안하는 알고리즘을 사용하여 혈류량과 심박구출률을 계산하였고, 수동윤곽검출 및 General Electronics 사의 MASS 소프트웨어와 비교하였다. 제안한 알고리즘의 수동윤곽검출과 차이는 혈류량의 경우 평균적으로 이완기에 $4.6mL{\pm}3.9$, 수축기에 $2.1mL{\pm}2.4$로 나타났고, 심박구출률은 $1.8%{\pm}1.7$이었다. 전반적으로 MASS소프트웨어에 비해 좋은 성능을 나타내었다.

Design of a Lossless Audio Coding Using Cholesky Decomposition and Golomb-Rice Coding (콜레스키 분해와 골롬-라이스 부호화를 이용한 무손실 오디오 부호화기 설계)

  • Cheong, Cheon-Dae;Shin, Jae-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.11
    • /
    • pp.1480-1490
    • /
    • 2008
  • Design of a linear predictor and matching of an entropy coder is the art of lossless audio coding. In this paper, we use the covariance method and the Choleskey decomposition for calculating linear prediction coefficients instead of the autocorreation method and the Levinson-Durbin recursion. These results are compared to the polynomial predictor. Both of them, the predictor which has small prediction error is selected. For the entropy coding, we use the Golomb-Rice coder using the block-based parameter estimation method and the sequential adaptation method with LOCO-land RLGR. The proposed predictor and the block-based parameter estimation have $2.2879%{\sim}0.3413%$ improved compression ratios compared to FLAC lossless audio coder which use the autocorrelation method and the Levinson-Durbin recursion. The proposed predictor and the LOCO-I adaptation method could improved by $2.2879%{\sim}0.3413%$. But the proposed predictor and the RLGR adaptation method got better results with specific signals.

  • PDF

Bioactive Foam Reactors for the Enhanced Biological Degradation of Toluene (계면활성제 거품을 이용한 미생물반응기에서의 기체상 톨루엔 분해)

  • Kim, Yong-Sik;Son, Young-Kyu;Khim, Jee-Hyung;Song, Ji-Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.468-475
    • /
    • 2005
  • Biofilters packed with various materials have emerged as a sustainable technology for the treatment of volatile organic compounds (VOCs); however, problems including low performance and clogging are commonly encountered. Recently, a bioactive foam reactor (BFR) using surfactants has been suggested to ensure efficient and stable VOCs removal performance. This study was mainly conducted to investigate the feasibility of BFRs using toluene as a model compound. Prior to bioreactor studies, a series of bottle tests were used to select a suitable surfactant for the BFR application. Experimental results of the batch bottle tests indicated that TritonX-100 was the most appropriate one among the surfactants tested, since it showed a minimal effect on the toluene biodegradation rate while the other surfactants lowered the toluene biodegradation rate significantly. Using the selected surfactant, the BFR performance was determined by changing operating parameters including gas residence time and toluene loading. As the gas residence time increased from 0.5 minutes to 2 minutes, the toluene removal efficiency increased from approximately 50% to 80%. In addition, an increase of the toluene loading from $38\;g/m^3/hr$ to $454\;g/m^3/hr$ resulted in a decrease of toluene removal efficiency from approximately 70% to 20%. The BFR had a maximum elimination capacity of $108\;g/m^3/hr$ for toluene, which was much higher than those generally reported in the literature. The high toluene-elimination performance indicates that the BFR be a potential alternative to the conventional, packed-type biofilters. However, the limitation of toluene solubilization and foam stability at either high or low gas flow rate are still problems to be challenged.

Clinical Analysis of the Recent Results of Coronary Artery Bypass Grafting (관상동맥 우회술의 최근성적에 대한 임상적 고찰)

  • Han, Sung-Ho;Kim, Hyuck;Lee, Chul-Bum;Chung, Won-Sang;Jee, Heng-Ok;Kang, Jung-Ho;Kim, Young-Hak
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.523-529
    • /
    • 2002
  • Background: Previous reports present that the early results of coronary artery bypass grafting (CABG) has been improving with the accumulation of surgical experience. We conducted a retrospective analysis of the patients who received CABG to evaluate the recent results of CABG. Material and Method: Between January 1996 and August 2001, 154 patients underwent CABG at Hanyang University Hospital. There were 47 patients(group I) who were operated between 1996 and 1998, and 107 patients(group II) who were operated thereafter. The preoperative diagnosis, operative procedure, mortality, and complications were analyzed retrospectively. Result: There were 35 males and 12 females in group I, and 78 males and 29 females in group II, which shows similar ratio of sexes between the two groups. The average age of patients for group I and group II was $55.9{\pm}6.2$ years and $61.0{\pm}8.0$ years, respectively, showing a significant increase in group II(p<0.05). The average left ventricular ejection fraction(LVEF) for group I and group II was $54.6{\pm}11.8$% and $56.9{\pm}13.0$%, respectively. The number of patients who had previous MI in group I and group II were 13 patients(27.7%) and 14 patients(13.1%), respectively, which shows a significant difference (p<0.05). All procedures were performed using the cardiopulmonary bypass(CPB) and moderate systemic hypothermia. Myocardial protection was achieved using intermittent hypothermic ischemia under ventricular fibrillation state or cold crystalloid cardioplegic solution for most of group I patients, whereas cold blood cardioplegic solution was used for group II patients. The mean CPB times for group I and group II were $149.2{\pm}48.7$ minutes and $113.1{\pm}30.6$ minutes, respectively. The mean aortic cross clamp times for group I and group II were $81.3{\pm}26.5$ minutes $72.2{\pm}23.9$ minutes, respectively. These figures show that CPB and aortic cross clamp times were significantly reduced in group II(p<0.05). The use of the left internal thoracic artery(LITA) was increased from 42%(20/47) for group I to 81% (87/107) for group II. The mean number of grafts also significantly increased from $2.5{\pm}0.6$ for group I to $3.0{\pm}1.1$ for group II(p<0.05). Intra-aortic balloon pump(IABP) was applied in 7 cases in group I and 17 cases in group II. Of these, 28.6%(2/7) and 52.9%(9/17) were broadly applied preoperatively in patients with LVEF<40% or congestive heart failure. The operative mortalities for group I and II were 10.6%(5/47) and 0.9%(1/107), respectively, which shows significant decrease for group II(p.0.05). Conclusion: This report suggest that CABG using CPB can recently be performed more safely in virtue of the accumulation of surgical experience with reduction in CPB and aortic cross clamp times and improved surgical techniques and myocardial protection. And we think that the optimal treatment of patients with left ventricular dysfunction associated with congestive heart failure and the extended application of IABP, especially have contributed to the reduction of operative mortality and morbidity.

The Comparison of Protective Effects of Adenosine Included Cardioplegia According to Adenosine Dosage (심정지액 속에 포함된 아데노신의 용량에 따른 심근보호 효과 비교)

  • 유경종;강면식;이교준;임상현;박한기;김종훈;조범구
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.837-844
    • /
    • 1998
  • Background: Adenosine is secreted by myocardial cells during myocardial ischemia or hypoxia. It has many beneficial effects on arrhythmias, myocardial ischemia, and reperfusion ischemia. Although many investigators have demonstrated that cardioplegia that includes adenosine shows protective effects in myocardial ischemia or reperfusion injury, reports of the optimal dose of adenosine in cardioplegic solutions vary. We reported the results of beneficial effects of single dosage(0.75 mg/Kg/min) adenosine by use of self-made Langendorff system. But it is uncertain that dosage was optimal. The objective of this study is to determine the optimal dose of adenosine in cardioplegic solutions. Material and Method: We used a self-made Langendorff system to evaluate the myocardial protective effect. Isolated rat hearts were subjected to 90 minutes of deep hypothermic arrest(15$^{\circ}C$) with modified St. Thomas' Hospital cardioplegia including adenosine. Myocardial adenosine levels were augmented during ischemia by providing exogenous adenosine in the cardioplegia. Three groups of hearts were studied: (1) group 1 (n=10) : adenosine - 0.5 mg/Kg/min, (2) group 2(n=10): adenosine -0.75 mg/Kg/min, (3) group 3 (n=10) : adenosine -1 mg/Kg/min. Result: Group 3 resulted in a significantly rapid arrest time of the heart beat(p<0.05) but significantly slow recovery time of the heart beat after reperfusion(p<0.05) compared to groups 1 and 2. Group 2 showed a better percentage of recovery(p<0.05) in systolic aortic pressure, aortic overflow volume, coronary flow volume, and cardiac output compared to groups 1 and 3. Group 1 showed a a better percentage of recovery(p<0.05) in the heart rate compared to the others. In biochemical study of drained reperfusates, CPK and lactic acid levels did not show significant differences in all of the groups. Conclusion: We concluded that group 2 [adenosine(0.75 mg/Kg/min) added to cardioplegia] has better recovery effects after reperfusion in myocardial ischemia and is the most appropriate dosage compared to group 1 and 3.

  • PDF

Early Bronchoconstriction After Allergen Challenge of Nonanesthetized Guinea Pigs (Ovalbumin으로 감작된 기니픽에서 Allergen 흡입으로 인한 즉시형 기관지 수축반응에 대한 비침습적 측정)

  • Kim, Je-Hyeong;Shim, Jae-Jeong;Lee, Sung-Yong;Kwon, Young-Hwan;Lee, So-Ra;Lee, Sang-Youb;Cho, Jae-Youn;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.99-106
    • /
    • 1998
  • Background: Bronchial asthma is a complex disease, which is characterized by spontaneous exacerbations of airway obstruction and persistent bronchial hyperresponsiveness. Animal models have fallen short of reproducing the human disease, particularly in mimicking the spontaneous and persistent airflow obstruction that characterized in asthma. In animals, airflow obstruction is usually assessed by measuring airflow resistance during tidal breathing under such invasive technique as tracheostomy and anesthesia. A noninvasive technique for measuring pulmonary function in small animals is needed to evaluate long-term changes in lung function during the course of experimentally produced disease without sacrificing the animal. Purpose: The purpose of this study was to evaluate early bronchoconstrcition after allergen challenge and airway responsiveness (AR) to inhaled methacholine in nonanethetized, unrestrained guinea pigs. Method: Guinea pig model of asthma was sensitized by subcutaneous injection with ovalbumin and challenged by inhalation of aerosolized ovalbumin(1% wt/vol ovlabumin). Airflow obstruction of conscious guinea pig was measured as specific airway resistance (airway resistance $\times$ thoracic gas volume). Airway resistance and thoracic gas volume of conscious guinea pig were assessed by body plethysmography before challenge and at regular intervals for as long as 30 minutes after challenge. AR to aerosolized methacholine of asthma group was compared with that of control group in body plethysmography. Result: Asthma model<> developed in 13 (65%) among 20 guinea pigs, in which early responses occurred in the airways after the exposure to inhalation with ovalbumin. Airway challenge with ovalbumin caused increase in specific airway resistance, which peaked at 6 minutes and amounted to a $231.5{\pm}30.4%$ increase from baseline. AR to aerosolized methacholine of asthma model increased significantly compared with control group. Conclusion: These results have showed a useful animal model to evaluate early bronchoconstrcition after allergen challenge and airway responsiveness in nonanethetized, unrestrained guinea pigs.

  • PDF