• Title/Summary/Keyword: 부재력

Search Result 753, Processing Time 0.024 seconds

Effect of Aspect Ratio in Direct Tensile Strength of Concrete (콘크리트 직접인장강도의 세장비 효과)

  • Hong, Geon-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.246-253
    • /
    • 2003
  • Although concrete members are not normally designed to resist direct tension, the knowledge of tensile strength is of value in estimating the cracking load. In general, there are three types of test method for tensile strength ; direct tension test, flexural tension test, and splitting tension test. Though direct tensile strength represents the real tensile strength of concrete, direct tension tests are seldom carried out, mainly because it is very difficult to applicate a pure tension force. The purpose of this paper is to investigate the test methods, effect of aspect ratio, and the size effect on the direct tensile strength. Direct tension test, using bonded end plates, follows RILEM and U.S.Bureau of Reclamation. And other test methods follow ASTM provisions. Four kinds of aspect ratio and two kinds of size effect are tested. Same variables are tested by direct tension test and splitting tension test for comparison between the two test methods. Test results show that direct tensile strength of concrete is more affected by aspect ratio and size than other kinds of strength.

A Study on Load Bearing Capacity of Composite Member with Steel Rib and Shotcrete in NATM Tunnel (NATM 터널에서 강지보와 숏크리트 합성부재의 하중지지력에 관한 연구)

  • Moon, Sang Hwa;Shin, Young Wan;Kim, Seung Hwan;Yoo, Han Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5C
    • /
    • pp.221-229
    • /
    • 2012
  • Steel ribs such as H-beam or lattice girder are often reinforced to secure the stability of NATM tunnel when the ground is in the bad condition. When designing, however, steel ribs are not often taken into consideration on the numerical analysis when they are regarded as temporary tunnel supports until shotcrete shows its best performance or if they are, there are various modeling methods. This study shows behavior and loading capacity of steel ribs and shotcrete through the strength test on the bending, pressure and full-scaled. Also, we conducted and analyzed the experiment of composite member consisting of shotcrete and steel ribs under the same condition. Through the result, we can find the fact that shotcrete and steel ribs do not work as one unit because of slipping on the boundary. Also, when numerical analyzing, it was concluded that steel ribs cover all bending moment and shotcrete and steel ribs share with axial force according to the compressive strength.

Friction Stir Welding of 7075-T651 Aluminum Plates and Its Fatigue Crack Growth Property (7075-T651 알루미늄 판재의 마찰교반용접과 피로균열전파 특성)

  • Kim, Chi-Ok;Sohn, Hye-Jeong;Kim, Seon-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.10
    • /
    • pp.1347-1353
    • /
    • 2011
  • Friction stir welding (FSW) method has extensively been used in manufacturing methods because of the several advantages over conventional welding methods, such as better mechanical properties, reduced occurrence of joining defects, high material saving, and low production time, etc. The aim of this paper is to review the optimal FSW conditions using the previous experimental results and is to investigate the fatigue crack growth rate in three different zones, WM, HAZ and BM for FSWed Al7075-T651 aluminum plates. As far as our experiments are concerned, the optimal conditions are obtained as rotation speed, 800rpm and travelling speed, 0.5mm/sec. The fatigue crack growth rate showed strong dependency on three different zones WM, HAZ and BM, and crack driving force.

An Experimental Study on Splitting Bond Strength of RC Column Reinforced with External Steel-Band (스틸밴드로 외부 보강된 철근콘크리트 기둥의 부착강도에 관한 실험적 연구)

  • Kim, Chang-Sik;Yoon, Seung-Joe;Ho, Seung-Woong;Yoon, Pil-Joong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.41-49
    • /
    • 2014
  • In order to investigation splitting bond strength of the deformed longitudinal reinforcing bars in the R C members strengthened laterally with the external steel-band, a total 9 sets of test re-bars with and without active confining force given by the external steel-band are pulled monotonically until failure. Test results indicate that the bond strength becomes higher with the increase in number of steel-band sets and their initial stress magnitude. This is due to the active confining force given by the steel-band, and passive confining forces given by the steel-band and transverse reinforcements, in which the passive confinement effect varies depending on the magnitude of active confining force. An equation to estimate the splitting bond strengths for the R C members strengthened laterally with the external steel-band is developed based on the several experimental results of the present study.

A Study on Roughness Coefficient Estimations in Gravel Bed Stream without Water Level-Discharge Data (수위-유량자료가 부재한 자갈하천의 조도계수 산정에 관한 연구)

  • Lee, Sin-Jae;Park, Sang-Woo
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.12 s.173
    • /
    • pp.985-996
    • /
    • 2006
  • This study developed a model that could calculate equivalent roughness using shear stress acting on distributed grains in gravel bed stream. The estimated equivalent roughness by the model developed was used for estimation of water level and roughness coefficient in the stream without water level-discharge data. The model was applied to the Gurey-Songjeong stage station section located in the Sumjin river mid-downstream. The equivalent roughness by the model developed in this study was estimated to be 0.194m at the Gurey stage station. Calculated water level which the estimated equivalent roughness was applied to the flow model was shown ewer of within 6% in comparison with observed water level. Also, roughness coefficient was estimated using observed and calculated water level about each discharge scale by unsteady flow analysis. As a result, error of roughness coefficient estimated by observed and calculated water level was shown error of $0{\sim}0.002$ and could consider variability of roughness coefficient.

Approximate Analysis of Shear Wall-Frame Structure For Seismic Design (전단벽-골조 시스템의 내진설계를 위한 근사해석법)

  • Yoo, Suk-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.99-106
    • /
    • 2019
  • A wall-frame structure resists horizontal load by the interaction between the flexural mode of the shear wall and the shear mode of the frame, which implies that the frame deflects only by reverse bending of the columns and girders, and that the columns are axially rigid. However, as the height of frame increases the shear mode of frame changes to flexural mode, which is due to the extension and shortening of the columns. An approximate hand method for estimating horizontal deflection and member forces in high-rise shear wall-frame structures subjected to horizontal loading is presented. The method is developed from the continuous medium theory for coupled walls and expressed in non-dimensional structural parameters. It accounts for bending deformations in all individual members as well as axial deformations in the columns. The deformations calculated from the presented approximate method and matrix analysis by computer program are compared. The presented approximate method is more accurate for the taller structures.

Dynamic Responses of Offshore Meteorological Tower Under Wind and Wave (바람과 파랑을 받는 해상 풍력 기상탑의 동적 응답)

  • Kwon, Soon-Duck
    • Journal of the wind engineering institute of Korea
    • /
    • v.22 no.4
    • /
    • pp.171-177
    • /
    • 2018
  • In order to investigate the cause of damage of the offshore meteorological tower, the measured wind speed data were analyzed, the dynamic displacement due to fluctuating wind load and wave load was calculated, and the fatigue was examined for vortex-induced vibration. It was confirmed from the results that the vibration lasting for four hours occurred in the meteorological tower when the maximum wind speeds for 10 minutes were compared for both the vane anemometer and ultrasonic anemometer. The effect of the gust wind on the dynamic response of the meteorological tower was greater than the wave. However, the combined forces acting on the meteorological tower was much lower than the design force even though the wind and wave loads were simultaneously applied. The vortex-induced vibration seemed to be cause of the fatigue failure in the connecting bolts. The destruction of the offshore meteorological tower was considered to be a vortex-induced vibration, not a fluctuating fluid flows.

A Study on the Case Analysis by Type of the Cadastral Surveying Screening (지적측량 적부심사 유형별 사례분석에 관한 연구)

  • OH, Yi-Kyun
    • Journal of Cadastre & Land InformatiX
    • /
    • v.52 no.2
    • /
    • pp.137-152
    • /
    • 2022
  • The cadastral boundary points which cadastral surveyor presented on the ground by conducting cadastral surveying represents the limits of land ownership and give binding force and determination power. However the land disputes have increased these days mainly due to cadastral registration errors, surveying errors and land owners recognition error. In these cases, the cadastral survey interests try to find solution by either a administrative procedures by appealing civil complaint or border determination litigation through court. The neighboring residents and related organization have difficulties in resolving the civil complaints. In this study cadastral surveying and cadastral boundary determination process has been reviewed and the results of cadastral surveying screening by Central Cadastre Committee from 2016 to 2021 have been classified. The outcomes of this research will be used for cadastral surveying and contribute for reducing land disputes and improve reliablity of cadastral surveying.

Seismic Design of Columns in Inverted V-braced Steel Frames Considering Brace Buckling (가새좌굴을 고려한 역 V형 가새골조의 기둥부재 내진설계법)

  • Cho, Chun-Hee;Kim, Jung-Jae;Lee, Cheol-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • According to the capacity design concept which forms the basis of the current steel seismic codes, the braces in concentrically braced frames (CBFs) should dissipate seismic energy through cyclic tension yielding and cyclic compression buckling while the beams and the columns should remain elastic. Brace buckling in inverted V-braced frames induces unbalanced vertical forces which, in turn, impose the additional beam moments and column axial forces. However, due to difficulty in predicting the location of buckling stories, the most conservative approach implied in the design code is to estimate the column axial forces by adding all the unbalanced vertical forces in the upper stories. One alternative approach, less conservative and recommended by the current code, is to estimate the column axial forces based on the amplified seismic load expected at the mechanism-level response. Both are either too conservative or lacking technical foundation. In this paper, three combination rules for a rational estimation of the column axial forces were proposed. The idea central to the three methods is to detect the stories of high buckling potential based on pushover analysis and dynamic behavior. The unbalanced vertical forces in the stories detected as high buckling potential are summed in a linear manner while those in other stories are combined by following the SRSS(square root of sum of squares) rule. The accuracy and design advantage of the three methods were validated by comparing extensive inelastic dynamic analysis results. The mode-shape based method(MSBM), which is both simple and accurate, is recommended as the method of choice for practicing engineers among the three.

A Technical Report on the Design and Construction of Hybrid Tension Roof Structure of Incheon Munhak Stadium (인천문학경기장 지붕구조의 설계와 시공)

  • Seok Hwangbo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.194-201
    • /
    • 2003
  • 대공간 구조시스템은 일반적으로 자중을 최소화하고 부재내력의 효과적인 사용이 매우중요하다. 따라서 준공후의 외력에 대한 구조적 거동에 대한 파악도 중요하지만 시공중의 거동에 대한 파악도 매우 중요하다. 특히 케이블 막구조의 경우 시각초기에 구조물이 불안정하지만 케이블에 장력이 도입되면서 점차적으로 구조물의 강성이 높아져 구조물이 안정화를 이루게 피므로 시공과정 해석 즉 안정화 이행과정해석이 시공계획을 설정하는 부분에서 매우 중요한 요소가 된다. 본고에서는 케이블 막구조의 실례로써 최근 완공된 인천문학 경기장 지붕구조를 대상으로 시공과정과 안정화 이행과정해석에 대한 소개를 한다. 인천문학경기장 지붕구조는 케이블에 장력을 도입하는 과정에서 발생되는 변형과 내력을 흡수하고 하부구조에 대한 영향을 최소화하기 위하여 마스크 지점의 회전과 이동이 가능한 특수공법을 채택하였으며 시공과정해석(안정화이행과정해석)을 통하여 제시된 단계별 목표장력 및 변위에 따라 시공과정이 계획되고 제어되었다. 특히 외국의 기술로 설계된 자료를 근거로 일방적으로 공사를 수행한 다른 구조물과는 다르게 국내의 기술력에 바탕한 구조 해석 등을 통하여 검증하여 최종 시공방법을 결정하였고 이러한 과정을 통하여 대공간 구조에 대한 기술력을 확보하고 확인할 수 있었으며, 그 결과 향후에는 국내의 기술력으로 이와 같은 대규모의 케이블 막구조의 설계와 시공이 가능할 것이라고 판단된다.

  • PDF