• Title/Summary/Keyword: 복합에너지시스템

Search Result 480, Processing Time 0.032 seconds

Experimental Investigation of Complex System for Electrical Energy Harvesting and Vibration Isolation (미소진동 발생원으로부터의 전기에너지 재생 및 진동절연을 위한 복합시스템의 실험적 성능검증)

  • Kwon, Seong-Cheol;Jeon, Su-Hyeon;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.1
    • /
    • pp.40-48
    • /
    • 2016
  • Micro-vibration induced by on-board appendages that have mechanical moving parts has always been treated as an useless objective that has to be isolated, in order to comply with a high-resolution mission requirement of the observation satellite. In this study, we proposed a tuned mass damper energy harvester combined with a conventional passive vibration isolator for exhibiting dual functions of both electrical energy harvesting and micro-vibration isolation. The feasibility of the proposed dual-function complex system has been demonstrated through the comparison with numerical simulations, based on the results of basic characteristic tests, and experiments of the harvested power and micro-vibration.

Numerical approach for comparative performance study of tube type and box type hybrid photovoltaic/thermal system (시뮬레이션을 통한 박스형과 튜브형 태양광열 복합 시스템의 성능 분석)

  • Bhattarai, Sujala;Kim, Dae-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.9-18
    • /
    • 2011
  • 태양광열 복합 시스템(photovoltaic/thermal hybrid solar system, PV/T)은 태양광 모듈 및 태양열 집열판의 단일화를 통한 전기 및 열에너지의 동시 생산이 가능하도록 구성되고 기존 태양광 모듈의 온도 상승에 따른 효율 저하의 문제점을 보완 및 발생하는 열을 회수하여 온수 생산이 가능한 장치이다. 본 연구에서는 액체형 PV/T 시스템의 대표적인 두 형태인 박스형과 튜브형의 성능 검증을 위하여 수학적 모델링을 통한 두 시스템의 열 및 전기적 성능을 비교 분석하였다. 모델링은 에너지 평형식을 이용하여 시간에 따른 각 부분의 온도의 변화를 예측할 수 있도록 수립되었으며 계산된 결과를 기준으로 전기, 열, 및 전체효율을 도출해 내고, 이를 바탕으로 두 시스템의 성능을 분석하였다. 시뮬레이션 결과를 바탕으로, 박스형 PV/T 시스템의 최고 온수 온도는 $52^{\circ}C$로 예측되었고, 반면에 튜브형은 $48^{\circ}C$에 머물렀다. 또한 열효율은 박스형이 최대 51%, 튜브형이 41%, 전기효율은 박스형이 약 14%, 그리고 튜브형이 13%로 나타났으며, 전체효율은 박스형이 73%, 그리고 튜브형이 64%로 나타나 박스형 PV/T 시스템이 튜브형보다 더 나은 성능을 가지는 것으로 예측되었다. 이는 박스형이 튜브형보다 태양광 모듈과 온수와의 접촉면적이 넓어 더 많은 열전달이 발생하기 때문으로 사료된다.

The Performance and the NOx Emission Characteristics of the Combined Cycle Using Medium-Btu Coal Gas (중발열량 석탄 가스를 사용하는 복합발전 사이클의 성능 및 NOx 배출 특성)

  • Lee, Chan;Yun, Yong-Seong
    • Journal of Energy Engineering
    • /
    • v.9 no.4
    • /
    • pp.295-302
    • /
    • 2000
  • 증발열량 석탄가스 연료를 사용하는 석탄가스와 복합 발전 플랜트의 성능 및 NOx 배출량을 동시에 예측하기 위한 모사 방법을 제시하였다. 본 방법은 복합 사이클의 열역학적 해석 기법을 토대로, 석탄가스화 복합발전 플랜트의 시스템 연계 및 석탄가스 연소에 의한 탈설계점 효과를 예측하는 모델들을 포함하고 있다. 본 방법에 의한 전산 모사 결과와 천연가스를 사용하는 복합발전소의 실제 시험 결과를 비교함으로써, 본 방법의 예측정확도를 검증하였다. 본 모사 방법을 이용하여, 서로 다른 4가지 석탄가스 연료에 대해, 공기 분리장치와의 다양한 연계 설계 조건에 따른 석탄가스화 복합발전 플랜트의 전체 성능, 운전 안전성 및 NOx 배출 특성들을 비교, 검토하였다.

  • PDF

Multi-Objective Evaluation for Hybrid Use of Natural Energy in Power System (자연에너지 복합 이용시스템에 대한 다목적 평가)

  • Bae, Sang-Hyun;Lee, Jae-Youn
    • Solar Energy
    • /
    • v.11 no.1
    • /
    • pp.27-40
    • /
    • 1991
  • Research and development works on practical application of natural energy utilization systems involving solar, wind and sea wave energies are under promoting for the purpose of improving the energy consumption structure. These natural energies, made available with the use of relatively simple apparatus, are clean economically efficient and highly effective in the conservation of environment. However, these natural energies also have low energy density, randomness and regional variations. To compensate for these characteristics, hybrid utilization of solar and wind energies is currently under study. The introduction of a plural number of the natural energy hybrid utilization systems into a specific area will affect the economic efficiency, reliability and environmental conservation. Evaluation method of such effects has been examined in this study. The present method consisted of the steps described below. First, available energy was calculated from insolation distribution and wind velocity distribution in the specified area, and then the effect on the configuration of the power system load was obtained. This was followed by the determination of the optimal power dispatch over the specified period and by evaluations in light of economic efficiency, reliability and environmental indices.

  • PDF

Molecular Dynamics Study of Anion Conducting Ionomer under Excessive Water Condition (과량의 수화상태에서 음이온 전도성 이오노머의 분자동역학 전산모사 연구)

  • Hoseong, Kang;So Young, Lee;Hyoung-Juhn, Kim;Chang Hyun, Lee;Chi Hoon, Park
    • Membrane Journal
    • /
    • v.32 no.6
    • /
    • pp.475-485
    • /
    • 2022
  • The continuous excessive consumption of fossil fuels is causing global warming, climate, and environmental crisis. Accordingly, hydrogen energy attracts attention among alternative energies of fossil fuels, because it has the advantage of not emitting pollutants and not having resource restrictions. Therefore, various studies are being conducted on a water electrolysis system for producing hydrogen and a fuel cell system for producing electricity by using hydrogen energy as a fuel. In this study, 3D ionomer models were produced by reflecting the excessive water condition of an anion-conductive ionomer material, which is one of the core materials of water electrolysis systems and fuel cells. Finally, by analyzing the structural stability and performance of the ionomer under an excessively hydrated condition, we suggested a performance improvement factor in the design of an anion conductive ionomer, a key material for water electrolysis systems and fuel cells.

Energy Analysis of A Combined Heat and Power Plant (엑서지분석에 의한 열병합발전의 효율제고에 관한 연구)

  • 오영삼;김종진;최기련;목영일
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.83-94
    • /
    • 1993
  • In this paper, the performance of an energy conversion system is analyzed using two efficiency concepts, one of conventional and the other of energetic efficiently. The objective of this analysis was to improve and optimize the energy conversion system in point, namely, and LNG-fired Combined Heat and Power Plant (CHP). To this end, energies which represent the true efficiency figures were evaluated for various flows of the system with a set of system configurations given. Then the economic values of the energies were assigned to respective flows and subsystems. With these economic data locations of inefficiencies and opportunities for improvement are identified.

  • PDF

Development of a HIL Simulator (HIL 시뮬레이터의 개발)

  • Jung, Seung-Hwan;Choy, Ick;Song, Joong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1589-1590
    • /
    • 2007
  • 본 논문에서는 대체에너지 발전시스템이 포함되는 복합발전시스템의 구성 및 운전 특성 등을 분석하고 종합적인 엔지니어링 기술 확보에 필요한 Hardware-in-the-loop(HIL) Simulator의 구조를 제시하며 이를 효율적으로 제어할 수 있는 운영 소프트웨어를 개발하였다. 개발된 HIL Simulator는 복합발전 시스템을 구성하는 서브시스템의 제어기를 설계하는데 유용하게 사용할 수 있다.

  • PDF

A Real-time Calculation Method on Performance Impact of Controllable Operation Parameters for Combined Cycle rower Plant (복합화력 제어가능 운전 파라미터의 실시간 영향산출 기법)

  • Joo Yong-Jin;Park Jong-Ho
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.67-73
    • /
    • 2006
  • A calculation method on performance impact of the controllable operations parameter such as GT inlet filter ${\Delta}P$, compressor efficiency, and condenser pressure was devised to achieve best performance of combined cycle power plant with the on-line performance monitoring system. This method calculates the performance impact on the deviation between 'Expected' values and 'Actual' values. Controllable parameter targets are determined based on achievable performance given existing equipments and control conditions.

Activated Carbon-Photocatalytic Hybrid System for the Treatment of the VOC in the Exhaust Gas from Painting Process (도장공정 배기가스 내 VOC 처리를 위한 활성탄-광촉매 복합시스템)

  • Lee, Chan;Cha, Sang-Won;Lee, Tae-Kyu
    • Journal of Energy Engineering
    • /
    • v.14 no.2 s.42
    • /
    • pp.133-139
    • /
    • 2005
  • An activated carbon-photo catalysis hybrid system is proposed for the treatment of VOC produced from paint booth. and its VOC removal performance is experimentally evaluated. Activated carbon tower is designed on the basis of the adsorption characteristics of toluene. Photocatalytic system is designed as the series of $TiO_2/SiO\_2$ fluidized bed reactor and $TiO_2$-coated filters. The present activated carbon-photo catalysis hybrid system shows the VOC removal efficiency within $75\~100\%$ under different VOC species and concentrations.

Recent Developments in Ion-Exchange Nanocomposite Membranes for Energy Applications (에너지용 이온 교환 복합막 최근 연구 개발 동향)

  • Hwang, Doo Sung;Chung, Tiffany;Wang, Tongshuai;Kim, Sangil
    • Membrane Journal
    • /
    • v.26 no.6
    • /
    • pp.432-448
    • /
    • 2016
  • In the last decade, various types of energy harvesting and conversion systems based on ion exchange membranes (IEMs) have been developed for eco-friendly power generation and energy-grid systems. In these membrane-based energy systems, high ion selectivity and conductivity properties of IEMs are critical parameters to improve efficiency of the systems such as proton exchange membrane fuel cells, anion exchange membrane fuel cells, redox flow batteries, water electrodialysis for hydrogen production, and reverse electrodialysis. This article suggests variable approaches to overcome trade-off limitation of polymeric membrane ion transport properties by reviewing various types of composite ion-exchange membranes including novel inorganic-organic nanocomposite membrane, surface modified membranes, cross-linked and pore-filled membranes.