• Title/Summary/Keyword: 보조펌프

Search Result 77, Processing Time 0.033 seconds

A Jitter Characteristic Improved PLL with RC Time Constant Circuit (저항-커패시턴스 시정수 회로를 이용하여 지터 특성을 개선한 위상고정루프)

  • An, Seong-Jin;Choi, Yong-Shig
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.2
    • /
    • pp.133-138
    • /
    • 2017
  • This paper presents a jitter characteristic improved phase locked loop (PLL) with an RC time constant circuit. In the RC time constant circuit, LPF's voltage is inputted to a comparator through small and large RC time constant circuits. The signal through a small RC time constant circuit has almost same loop filter output voltage. The signal through a large RC time constant circuit has the average value of loop filter output voltage and does as a role of reference voltage to the comparator. The output of the comparator controls the sub-charge pump which provide a current to LPF. When the loop filter output voltage increases, the sub-charge pump discharges the loop filter and decreases loop filter output voltage. When the loop filter output voltage decreases, the sub-charge pump charges the loop filter and increases loop filter output voltage. The negative feedback loop reduces the variation of loop filter output voltage resulting in jitter characteristic improvement.

A Low Phase Noise Phase Locked Loop with Current Compensating Scheme (전류보상 기법을 이용한 낮은 위상 잡음 위상고정루프)

  • Song, Youn-Gui;Choi, Young-Shig;Ryu, Ji-Goo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.12 s.354
    • /
    • pp.74-80
    • /
    • 2006
  • This work presents a novel architecture of phase locked loop (PLL) with the current compensating scheme to improve phase noise performance. The proposed PLL has two Charge Pump (CP), main-CP (MCP) and sub-CP (SCP). The smaller SCP current with same time duration but opposite direction of UP/DN MCP current is injected to the loop filter (LF). It suppress the voltage fluctuation of LF. In result, it improves phase noise characteristic. The Proposed PLL has been fabricated with 0.35fm 3.3V CMOS process. Measured phase noise at 1-MHz offset is -103dBc/Hz resulting in a minimum 3dBc/Hz phase noise improvement compared to the conventional PLL.

KSTAR 중성입자빔 입사장치의 크라이오 배기계통 설계 개념

  • 인상렬;박미영;오병훈
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.36-36
    • /
    • 2000
  • KSTAR 토카막은 보조가열 장치로 2005년까지 1대(최종적으로는 2대)의 중성입자빔 입사장치(NBI)를 설치하여 장치의 기본 설계값에 도달할 예정이다. KSTAR NBI는 3개의 이온원을 가지고 있으며 총 수소 유입량은 70 Torr.L/s인 반면 고속 중성 입자빔량은 모두 11 Torr.L/s로 기체 배기량은 59 Torr.L/s에 달하고 압력은 장소에 따라 10-5~10-6 Torr로 유지되며 총배기속도가 1~2$\times$106 L인 펌프가 필요하다. 이때 크라이오 펌프(cryopump) 방식이 거의 유일한 해결책이라고 할 수 있다. 크라이오 펌프는 고속 입자빔 수송로의 양편에 각각 설치되는데 총면적 30m2 내외의 극저온 냉각판(cryo-pnael)들과 이를 상온 열복사로부터 보호하기 위한 열차폐(thermal shield) 및 흡기구 배플(baffle), 그리고 적절한 냉각장치로 구성된다. 시운전 단계에서는 15K GM 냉동기와 활성탄이 부착된 냉각판을 사용하는 방식과 4K GM 냉동기로 냉각하는 방식이, 최종 운전단계에서는 3.7K 액체 헬륨을 사용하는 방식이 고려되고 있다. 크라이오 펌프의 구조설계에 앞서 우선 배기속도, 흡?량, 작동압력, 냉각판 온도, 열손실량 등 설계사양을 확정하고 정리하는 일이 진행되고 있다. 또 냉각방식과 상관없이 동일한 개념으로 만들어지는 배플과 열차폐의 최적설계를 위한 몬테카를로 계산과 열전도 계산을 병행하고 있다. 이 곳에서는 KSTAR NBI 장치의 주배기계로서 사용될 크라이오 펌프의 설계방향과 전반적인 구조 및 예상성능 등에 대해 발표하려고 한다.

  • PDF

SOPHT 코드를 이용한 열수송계통의 정지냉각 천이해석

  • 김태한;김영보;정종식;한상구
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.371-376
    • /
    • 1995
  • CANDU-6형 원자로의 정지냉각계통(Shutdown Cooling System, SDCS)은 영출력 고온상태의 원자로를 상온상태로 냉각시킬 수 있도록 설계되었다. 본 해석은 증기발생기와 복수기증기방출밸브(CSDV) 및 정지냉각펌프를 이용한 정상냉각과 열수송펌프를 이용한 26$0^{\circ}C$부터 냉각 및 정지냉각펌프를 이용한 26$0^{\circ}C$부터 냉각의 두 가지 비정상냉각에 대해서 중수로 계통설계의 열수력 해석코드인 SOPHT 코드를 사용하여 해석하였다. 해석결과에 따라 주요기기들의 냉각천이에 따른 운전부하(service loadings)조건이 주어졌으며 또한 정지냉각계통은 열수송계통과 관련 보조계통을 정지냉각계통 열교환기 2차측에서 비등이 발생하지 않고 정상냉각 허용한계인 2.8$^{\circ}C$/min를 만족하면서 냉각할 수 있음을 확인하였다.

  • PDF

이온빔 보조 증착으로 제조된 카본 박막의 특성 연구

  • 손민규;박형국;손영호;박노길;정재인
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.132-132
    • /
    • 1999
  • 카본 박막은 내마모성, 내산성, 윤활성 및 높은 경도를 가지고 있어, 경질 박막 및 기능성 박막으로 주목을 받고 있으며 그 응용 분야가 매우 크다. 본 연구는 전자빔(Electron Beam)을 카본 grain을 증발시킴과 동시에 아르곤 보조 이온빔을 조사시켜 이온에너지에 따른 박막의 물성변화를 관찰하였다. 특히 본 연구에서 이용한 이온빔 증착 장치의 장점은 이온 충돌 에너지의 조절이 가능하다는 것이다. 카본 박막의 제조는 이온빔이 증착된 고진공 증착 장치를 이용하였고 이원빔원으로는 Oxford Applied Research 사의 RF 방전형 이온빔을 이용하였다. 배기장치는 유회전펌프와 터보펌프를 사용하였다. 기판은 홀더에 장착하기 전에 전처리를 거친 후 용기 내에서 이온빔에 의해 2차 청정을 하였다. 빔전압이 500V, 빔 전류는 4mA/cm2 및 RF power를 400W로 하여 기판 청정을 거친 후 전자빔을 이용하여 흑연을 증발시켜 박막을 제조하였다. 이때 이온빔 전압을 100~500V, RF power를 400~550W 으로 조절하였다. 카본 grain을 Si 및 Slide Glass 기판위에 1$\AA$/sec의 증착율을 유지하면서 증착하였다. 카본 박막의 박막은 평균두께는 0.3~0.4$\mu\textrm{m}$이며 SEM을 이용하여 단면을 관찰하였다. 라만 분광분석을 통하여 비정질 카본 박막의 결합특성을 조사하였고 scratch tester를 이용하여 박막의 밀착력을 관찰하였다. 그리고 카본 박막의 전도도 특성을 알고자 비저항을 측정하였으며, 박막의 성분 분석을 위한 AES 분석을 하였다. 1)AES 결과:표면에서와 박막 내부에서는 불순물인 산소나 질소의 함량이 거의 존재하지 않음을 관찰하였다. 2)경도:1,000~1,400kg/mm2 3)라만 분광 분석:300V의 이온 에너지를 분기로 박막 구조의 변화에 의한 스팩트럼의 변화를 보였다. 4)비저항:10-2~10-1$\Omega$.cm

  • PDF

Plate Type New Distributor Development for Hydraulic Motors and Pumps (유압모터 및 펌프용 판 형태의 새로운 분배기 개발)

  • Jin, Seong-Mu;Kim, Hyeong-Ui
    • 한국기계연구소 소보
    • /
    • s.18
    • /
    • pp.75-85
    • /
    • 1988
  • The distributor for hydraulic pumps or motors, particularly radial piston motors, include rotary member which has equally both surface shape for dynamic balance and two fixed members, located in both side of rotary member, which have equal surface shape for dynamic balance and circular ring which use to retain predetermined clearance between two fixed members. Rotary member must have valve part for flow-distribution and can have hydrostatic bearing for excellently dynamic balance. At least two annular steps located on said pressure plate which use in compensation of bolt expansion.

  • PDF

Performance Optimization of a Hybrid Ground Source Heat Pump According to Secondary Flow Distribution Ratio between the Ground and the Supplemental Loop (지중 및 보조루프의 2차 유체 유량 분배비를 통한 하이브리드 지열히트펌프의 성능 최적화 연구)

  • Lee, Joo-Seong;Park, Hong-Hee;Kim, Won-Uk;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.102-110
    • /
    • 2012
  • The objective of this study is to improve the performance of a hybrid ground source heat pump (HGSHP) by optimizing the flow distribution ratio of secondary fluid flow rate between a ground loop and a supplemental loop. Initially, a conventional ground source heat pump (GSHP) was tested to determine an optimum flow rate of the secondary fluid. Based on the selected optimum value, the HGSHP was also tested by varying the flow distribution ratio of the secondary fluid flow rate between the ground loop and the supplemental loop, such as 9:1, 7:3, 5:5, and 3:7. The results showed that the optimum flow distribution ratio of the secondary fluid flow rate was 7:3. The COP of the HGSHP was improved by 19% over the GSHP at a flow distribution ratio of 7:3 and an entering water temperature of $40^{\circ}C$.

Heat-up Calculation for the Auxiliary Feed Water Pump Room at Ulchin Units 3 and 4 for Loss of HVAC Accidents (HVAC 상실사고시 울진원전 3/4 호기의 보조급수펌프 격실 온동상승 평가)

  • Yoon, Churl;Park, Jin-Hee;Hwang, Mee-Jeong;Han, Sang-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.553-562
    • /
    • 2012
  • Computational Fluid Dynamics (CFD) analysis has been performed to estimate the air temperature inside an Auxiliary Feed Water (AFW) Motor-Driven (MD) pump room for the case where there is loss of Heating, Ventilation, and Air-Conditioning (HVAC). A transient calculation for the closed pump room without cooling by any HVAC system shows that the volume-averaged air temperature reaches around $60^{\circ}C$ for a transient period of 8.0 h. From previous studies, the external air and surface boundary temperatures are assumed to increase slowly starting from an initial temperature of $35^{\circ}C$. For the cases where the door is opened at 2, 4, and 6 h after the initiation of HVAC failure, the average air temperature promptly drops by about $4^{\circ}C$ when the door is opened and then slowly increases. The current calculations based on the CFD technique predict the rate of increase of air temperature to be lower than that determined by previous conservative calculations on the basis of a lumped model.

A Safety Improvement for the Design Change of Westinghouse 2 Loop Auxiliary Feedwater System (웨스팅하우스형 원전의 보조급수계통 설계변경 영향 평가)

  • Na, Jang Hwan;Bae, Yeon Kyoung;Lee, Eun Chan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.15-19
    • /
    • 2013
  • The auxiliary feedwater is an important to remove the heat from the reactor core when the main feedwater system is unavailable. In most initiating events in Probabilistic Safety Assessment(PSA), the operaton of this system is required to mitigate the accidents. For one of domestic nuclear power plants, a design change of a turbine-driven auxiliary feedwater pump(TD-AFWP), pipe, and valves in the auxiliary system is implemented due to the aging related deterioration by long time operation. This change includes the replacement of the TD-AFWP, the relocation of some valves for improving the system availability, a new cross-tie line, and the installation of manual valves for maintenance. The design modification affects the PSA because the system is critical to mitigate the accidents. In this paper, the safety effect of the change of the auxiliary feedwater system is assessed with regard to the PSA view point. The results demonstrate that this change can supply the auxiliary feedwater from the TD-AFWP in the accident with the motor-driven auxiliary feedwater pump(MD-AFWP) unavailable due to test or maintenance. In addition, the change of MOV's normal position from "close" to "open" can deliver the water to steam generator in the loss of offsite power(LOOP) event. Therefore, it is confirmed that the design change of the auxiliary feedwater system reduces the total core damage frequency(CDF).