• Title/Summary/Keyword: 보조전원

Search Result 225, Processing Time 0.024 seconds

A Study on TTX SIV Characteristic Using Measurement System (계측장치를 이용한 틸팅열차 보조전원장치 특성 연구)

  • Han, Yeong-Jae;Lee, Su-Gil;Park, Chun-Su;Han, Seong-Ho;Jeong, Gwon-Il;Lee, Yeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.178-180
    • /
    • 2008
  • With the increase in population, the area of human activities has expanded, resulting in the dramatic increase in the need for transportation system. Tilting trains are currently in operation in 13 countries around the world. TTX(Tilting Train express) has been developed by KRRI(Korea Railroad Research Institute) for last 6 years to satisfy the need. This train developed in this Project is designed for a design speed of 200km/h and a maximum operating speed of 180km/h. We developed a measurement system for on-line test. the measurement console desk is mounted on T car, which is designed as the DAQ system train. It is comprehensive of the industrial computers, LCD monitors, communication cards and the communication channel measurement system. Using this system, SIV performance evaluation was conducted.

  • PDF

New Uninterruptible Power Supply Using the Converter which is Secondary Auxiliary Soft Switching High Frequency Insulating PWM AC/DC (2차측 보조 소프트 스위칭 고주파 절연형 PWM AC/DC 컨버터를 이용한 새로운 무정전전원장치)

  • Suh, Ki-Young;Mun, Sang-Pil;Kim, Ju-Yong;Lee, Hyun-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.16-21
    • /
    • 2005
  • In paper, propose new partial resonance ZCS PWM controlled High frequency insulating Full-bridge DC/DC converter not using exciting current of high frequency transformer. It is compared with the existing principles in characteristics. It also realizes a widely stabilized ZVS operating using new ON-OFF control method at synchronized power rectification MOSFET of high frequency insulating transformer secondary. Besides, it is brought over 97[%] measurement efficiency by proposed DC-DC converts. It is proved effectiveness of new methods using DC UPS PWM rectifier as switching power supply.

A Study on Characteristic Analysis of Auxiliary Power Supply for Railway Vehicle (철도차량 보조전원장치 특성 분석에 관한 연구)

  • Han, Young-Jae;Han, Seong-Ho;Lee, Tae-Young;Lee, Su-Gil;Lee, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.177-181
    • /
    • 2017
  • Auxiliary power supply for railway vehicle is a equipment that focuses on the service of passengers in a vehicle. It supplies power to controllers used in heating and cooling devices, fluorescent lamps, batteries and many other electrical equipments. Most of the auxiliary power supply for railway vehicle are mainly used for the round trips and circulation routes within the metropolitan area and have a capacity of 170~200 kVA. In this study, we developed the auxiliary power supply capacity to 240kVA for 200km/h class. As such, the auxiliary power supply is an important device for securing the reliability and safety of the railway vehicle and improving the passenger convenience, so the performance verification of the performance must be ensured. In this paper, 240kVA auxiliary power supply is developed. Also, performance of the auxiliary power supply manufactured through the analysis of various characteristics related to the auxiliary power supply was confirmed while operating the actual line.

A Study on the Life Cycle Cost Evaluation of the Conventional Auxiliary Power Unit for 8200 Series Electric Locomotive (8200호대 전기기관차용 기존품 보조전원장치의 수명주기비용 평가에 관한 연구)

  • Lee, Kye-Seung;Kim, Wan-il;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.2
    • /
    • pp.331-336
    • /
    • 2018
  • In this paper, the life cycle cost of the auxiliary power unit in the conventional 8200 series electric locomotive is evaluated and an effective life cycle cost reduction method is sought. For this, a life cycle cost evaluation model was proposed using IEC 60300-3-3 standard. As a result of analysis, material cost which accounted for a large percentage of preventive maintenance cost, accounted for 64% of total cost, and breakdown maintenance cost was as high as 27%. Except for the cost of preventive maintenance, the breakdown maintenance cost ratio was the highest. In order to reduce the LCC of the auxiliary power unit(APU) of the 8200 series in the future, it is necessary to reduce the material cost in case of development and to secure the high reliability according to the parts manufacturing so as to minimize the maintenance cost.

Life Cycle Cost Analysis of Auxiliary Power Unit Developments for 8200 Series Electric Locomotive Based on Reliability (8200호대 전기기관차 보조전원장치 개발품의 신뢰도 기반 수명주기비용 분석)

  • Lee, Kye-Seung;Kim, Wan-il;Chang, Yoon-Woo;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1523-1529
    • /
    • 2018
  • Electric vehicles that are currently in operation are being produced domestically. Therefore, there is no great difficulty in receiving or repairing the failed parts or in the overall repair. On the other hand, most of the electric locomotives are manufactured by introducing the parts and technology of foreign vehicle manufacturers. In this paper, conducted a study about life cycle cost analysis of developed auxiliary power unit in 8200 series electric locomotive and suggested cost down method. This confirms the economic benefits of the developed products of the auxiliary power supply compared to the existing products. In addition, a sensitivity analysis of MTBF was conducted to suggest a life cycle cost down method.

A Study on the Auxiliary Power Supply for the Railway Vehicle by Using Wide Band Gap Device (Wide Band Gap 소자를 적용한 철도차량용 보조전원장치에 관한 연구)

  • Choi, Yeon-Woo;Lee, Byoung-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.168-173
    • /
    • 2018
  • In this paper, an auxiliary power supply (APS) for railroad cars is proposed. The APS can reduce the number of devices required to supply power through structural modification and operates at a high switching frequency by application of a SiC device. The voltage stress on the device in the proposed circuit can be reduced to less than half of the input voltage of the system; thus, a device with low breakdown voltage can be designed. By adapting a SiC device instead of an IGBT device, the proposed circuit can reduce switching and conduction losses and operate at a high switching frequency, thereby reducing output voltage and inductor current ripples in the proposed circuit. The theoretical analysis results of the proposed APS are verified with a 40 kW computer-based simulation and a 2 kW experiment.

A Study on Hybrid Control Unit Using a Smart Control (스마트 제어를 이용한 하이브리드 형 제어장치 연구)

  • Kim, Hee-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.11
    • /
    • pp.1093-1100
    • /
    • 2016
  • This study is to demonstrate the superiority and stability of the solar - wind power hybrid power generation system for street lamps using super capacitor EDLC(:Electric Double Layer Capacitor). It is aiming to apply the lighting device using LED light source as the load of solar-wind power hybrid power generation system for independent power source and to develop the street light system device with high output power generation system. Unlike conventional controllers, EDLC, which is used as an auxiliary device for storing the developed power in the battery, can guarantee the high output and long life of the battery.

The Development of IGBT Type 190kVA Static Inverter for Electric Car (전동차용 IGBT형 190kVA 보조전원장치 개발)

  • Kim, J.K.;Park, G.T.;Jung, K.C.;Kim, D.S.;Seo, K.D.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.634-637
    • /
    • 1997
  • This paper is on the research and development of new SIV(Static Inverter) using IGBT(Insulated Gate Bipolar Transistor) semiconductor for a wide range of electric railway applications. For the simplification and higher controllability, the direct PWM control method with 3level inverter topology was adopted. In the new SIV system, the cost as well as bulk and weight was appreciably reduced about 40% lower than those of conventional SIV, the electrical efficiency was increased above 95% and the audible noise level was less than 65dB. In addition, the THD(Total Harmonic Distortion) factor was below 5% and the voltage fluctuation on a transient state was below 10%.

  • PDF

Control of Parallel Hybrid Electric Vehicle using AI Logic (인공지능을 이용한 병렬 복합형 전기자동차 구동 시스템의 제어)

  • Koo, Euh-Suh;Kim, Woo-Suk;Choi, Hyun-Sung;Lee, Hyeoun-Dong;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.527-530
    • /
    • 1997
  • 최근 환경에 대한 각국의 관심이 높아지면서 자동차의 배기가스 및 소음에 관한 규제 차들이 날로 높아 가고 있는 실정이다. 이에 대한 해결책의 하나로 전기 자동차에 관한 관심이 고조되고 있으며, 특히 기계적 에너지와 전기적 에너지를 동시에 제어함으로써 외부의 별도 전원 공급이 필요 없이 구동이 가능한 병렬 복합형 전기자동차가 많은 연구의 대상이 되고 있다. 병렬 복합형 전기자동차의 전동기는 저속에서 구동 회전력을 보조하여 배기가스와 소음을 감소시키며, 고속에서는 내연 기관으로부터 에너지를 공급받아 배터리를 충전한다. 본 논문에서는 인공지능을 이용하여 다양한 주행 조건, 운행 패턴 등에 효과적으로 대응할 수 있으며 배기가스 및 소음을 감소시킬 수 있는 운행 제어 알고리즘을 제안하고 이를 주행시험을 통하여 그 타당성을 입증하였다.

  • PDF

A Three Level ZVZCS Phase-Shifted DC/DC Converter Using A Tapped Inductor And A Snubber Capacitor (탭-인덕터와 스너버-커패시터를 적용한 3 Level 영전압.영전류 스위칭 DC/DC 컨버터)

  • 김은수;김윤호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.209-216
    • /
    • 2001
  • The conventional three-level high frequency phase-shifted dc/dc converter has a disadvantage that a circulating current flows through transformer and switching devices during the freewheeling interval. Due to this circulating current and RMS current stress, conduction losses of transformer and switching devices increases. To alleviate these problems, we propose an improved three-level Zero Voltage and Zero Current Switchig (ZVZCS) dc/dc converter using a tapped inductor, a snubber capacitor and two snubber diodes attached at the secondary side of transformer. The proposed ZVZCS converter is verified on a 7kW, 30kHz experimental prototype.

  • PDF