• Title/Summary/Keyword: 보수이력

Search Result 123, Processing Time 0.028 seconds

Improvement of Physical Condition Assessment in Water Mains (상수도 관로의 물리적 상태평가 기준 개선)

  • Kim, Ju-Hwan;Lee, Doo-Jin;Bae, Cheol-Ho;Ahn, Hyo-Won;Hwang, Jin-Soo;Choi, Doo-Yong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1710-1715
    • /
    • 2010
  • Service life of water pipes buried in the underground is considerably affected from various factors such as environmental characteristics, pipe characteristics, operation and maintenance, etc. Therefore it is difficult to determine their service life as uniformly the same value assigned by related laws and ordinances. As a result, the service life should be determined by the technical judgement based on the assessment for the condition of water pipes. In this study, It was established that the methodology could predict present and future failure risk, and plan short and long-term strategies for replacement/rehabilitation through the assessment for the physical deterioration and economical values of buried water pipe. The methodology was applied for the verification and reliability to several sites selected in multi-regional transmission pipelines. The proposed method could helps to support reasonable and economical decision of rehabilitation/replacement in the present and future. To improve conventional assessment method of aged water pipes, affecting factors are simplified based on the statistical analysis results from the measured data in the field and the physical deterioration mechanism for better reliability. Also, the guide-line is developed to carry out the reasonal rehabilitation planning through water pipe condition assessment.

  • PDF

A Study of Port Facility Maintenance and Decision-making Support System Development (항만시설 유지관리 의사결정 지원 시스템 개발 연구)

  • Na, Yong Hyoun;Park, Mi Yeon;Choi, Doo Young
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.290-305
    • /
    • 2022
  • Purpose: Currently, port facility informatization technology is focused on the planning and design phases, so the necessity of research and technology development on the port facility maintenance system based on life cycle-level information is emphasized. Method: Based on the maintenance history data of port facilities and facility operation information, from the perspective of the life cycle of port facilities, the system is configured to enable maintenance decisions for port facilities through analysis of aging patterns, performance degradation prediction models, and risk analysis and proposed a method of expressing information. Result: A function was developed to simultaneously display the SOC performance evaluation and the comprehensive performance evaluation developed in this study, so that mid-to long-term maintenance and reinforcement and facility expansion can be applied and comparatively judged. Conclusion: The integrated port performance system developed in this study induces and supports the risk minimization of port facility management by proactively promoting appropriate repair and reinforcement measures through historical and operational information on port facilities.

Study on the Maintenance Cost of Railway Infrastructure Using Line Classification and TMV Data (선로등급 및 검측차 검측정보를 고려한 철도시설 유지보수비용 산정에 관한 연구)

  • Kim, In Kyum;Lee, Jun S.;Choi, Il Yoon;Lee, Hoo Seok
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.275-287
    • /
    • 2017
  • During the feasibility study of new rail lines, maintenance cost of railway infrastructure has mostly been estimated based on the track length and on simplified parameters; however, the estimation reliability can be improved by employing the correction factor from UIC 715, as well as the line classification in UIC 714. The correlations between maintenance cost and various parameters such as weighted track length based on line classification, radius of curvature, gradient and worn -out rate have been analyzed according to the case studies. Prediction of the maintenance cost has been carried out using the cost data, which were representative of the whole cost data; as a result, it was demonstrated that a cost model based on the line classification and the correction factor was more reliable than the existing models. Furthermore, possibilities of using data from both the track measurement vehicle and from the maintenance information system, which are under development, have been investigated and, based on this investigation, a combined cost model using line classification, radius of curvature, gradient and worn-out rate, among other factors, will be proposed in the near future.

Development of Effective Management System for the Sewerage Work (하수도 공사의 효율적 관리를 위한 공사 관리시스템 개발)

  • Jung Sung-Heuk;Lee Jea-Kee;Choi Seok-Keun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.1
    • /
    • pp.73-78
    • /
    • 2006
  • Cheongju city is executing a basic sewage maintenance plan for the systematic understanding of the sewage facilities, efficient preservation management, and reformation of the existent sewage facilities, in order to prevent the contamination of water and to preserve the neighboring environments. The new business constitute approximately 6% of the entire facility production, and renovation business constitute approximately 1.5% every year according to the statistics information of the last five years. This research provides effectiveness and reliability for sewage construction, and improvement in service for the civilians, through the efficient management of various documents, construction fees, design drawings, photographs, and construction background for the annually made constructions with the development of the effective management system for the sewage work.

Seismic Performance of RC Frame System Retrofitted with TS Seismic Strengthening Method(Part 2:Analytical Study) (TS 제진공법으로 내진보강된 철근콘크리트 골조의 내진성능(Part 2:해석적 연구))

  • Jung, Myung-Cheol;Song, Jeong-Weon;Song, Jin-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.148-153
    • /
    • 2018
  • In this study, the nonlinear time history analysis of seismic retrofitted structures with TS damper for seven ground motion records was conducted for the purpose of verifying the seismic strengthening effect of TS seismic retrofitting method. Through comparison of the interstory drift ratio and the energy dissipation amount of the non - reinforced structure obtained and those of retrofitted structures with TS damper from the nonlinear time history analysis, the interstory drift ratio was reduced by about 30% and the amount of energy dissipation through the structure was halved. As a result, it was confirmed that the damping performance of the TS seismic retrofitting method is excellent.

Evaluation of the Seismic Integrity of a Centrifugal Pump using Response Spectrum Analysis (응답 스펙트럼 해석을 이용한 원심펌프의 내진 건전성 평가)

  • Choi, Myung-Jin;Yoo, Ji-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.44-50
    • /
    • 2010
  • Vibration responses of a centrifugal pump required dynamic analysis for seismic qualification, were calculated by using spectrum analysis, which is known to be very simple compared with time domain analysis. Modal analysis was performed and the results were utilized in the spectrum analysis. The vibration responses calculated from the spectrum analysis were more conservative than those from the time domain analysis, that is, the former can be used as safer in design process. The pump was qualified for the specified seismic service conditions as specified in IEEE 344-1987. The maximum stresses were less than allowable stress limits. Based on the analysis results, it is concluded that the pump meets all the dynamic requirements of the applicable codes, standards, and technical specification.

Seismic performance evaluation of existing road tunnels based on revised seismic design code (개정된 내진설계기준에 기반한 기존 도로 터널의 내진 성능 평가)

  • Gyu-Phil Lee;Du-Hee Park;Ji-Eun Kang
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.525-540
    • /
    • 2023
  • Because of a new seismic design code has been enacted in 2023, there is a need to evaluate whether the road tunnels in operation satisfies the requirements of the new code. Four tunnels that are considered to be most susceptible to damage. Time history analyses are performed to quantify their seismic performances. The input ground motions generated to fit both 2007 and 2023 codes are used to evaluate the effect of the motions on the calculated responses. The analyses show that all tunnels perform favorably and satisfies the requirements successfully. Therefore, retrofit or reinforcement are deemed as unnecessary.

Effect of Thermal Aging on Material Strength and Fracture Behavior in Mod.9Cr-1Mo Steel (열시효가 Mod.9Cr-1Mo강의 재료강도 및 파괴 거동에 미치는 영향)

  • Lee, Hyeong-Yeon;Kim, Woo-Gon;Son, Seok-Kwon;Hong, Suk Woo;Seok, Chang Sung
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.2
    • /
    • pp.101-109
    • /
    • 2016
  • The material properties of heat resistant materials at power plants are affected by thermal aging as operating time is accumulated. In this study, the influence of thermal aging on yield strength, tensile strength and fracture behavior for Mod.9Cr-1Mo (ASME Grade 91) steel which is a material widely adopted for Generation IV nuclear energy system has been investigated and analyzed. Service exposed Gr.91 steel materials sampled from a piping system of an ultra-supercritical (USC) plant in Korea with accumulated operation time of 73,716 hours were used for material testing. The test results of the service exposed material specimens were compared with those of the virgin Gr.91 steel specimens. Those test data were compared with the material properties of ASME code and RCC-MRx code. Conservatisms of the material properties in the design codes have been quantified based on the comparisons of those from virgin and service exposed material specimens.

A Study on the Fatigue Crack Evaluation Method of Railway Bogie Frame (철도차량 대차를 피로균열 평가법 연구)

  • Jun, Hyun-Kyu;Seo, Jung-Won;Lee, Dong-Hyong;Kim, Hyeong-Jin
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.16-24
    • /
    • 2009
  • In this study, fatigue crack growth rate of a cracked railway bogie frame under variable amplitude loading is predicted by applying linear elastic fracture mechanics. For this purpose, we find the critical points by reference surveying on cracked railway bogie frames. And we make an effective load history by synthesizing the dynamic load measured from the critical points of railway bogie frame during commercial line operation and the static load calculated from structural analysis. Crack growth analyses are performed at the 3 critical points under the commercial operation loading condition by assuming an initial crack size as 40 mm. and the results are compared with the experimental results from Japanese railway bogie frame crack growth case. From the analysis results, we find that around 500,000 km operating distance is necessary to bring crack growth from the initial crack to unstable crack. And it takes around 3.8 normal operating years. We conclude that it is enough time to detect the crack between normal maintenance period.

Development of On-Line Life Monitoring System for high-Temperature Header of Fossile Powder Plant Boiler (화력발전소 보일러 고온헤더의 실시간 수명 감시시스템 개발)

  • 윤필기;정동관;윤기봉
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.605-611
    • /
    • 1999
  • Conventional methods for assessing remaining life of critical high temperature components in fossil power plants rely on nondestructive inspection practices and accompanying life analysis based on fracture mechanics By using these conventional methods. It has been difficult to perform uninterrupted in-service inspection for life prediction. Thus, efforts have been made for developing on-line remaining life monitoring systems employing information on the shape of structures, operating variables and material properties. In thus study, a software for on-line life monitoring system which performs real-time life evaluation of a high temperature system headers was developed. The software is capable of evaluating creep and fatigue life usage from the real-time stress data calculated by using temperatures/stress transfer Green functions derived in advance for the specific headers. The major benefits of the developed software life in determining future operating schedule, inspection interval, and replacement plan by monitoring real-time life usage based on prior operating history.

  • PDF