DOI QR코드

DOI QR Code

Seismic Performance of RC Frame System Retrofitted with TS Seismic Strengthening Method(Part 2:Analytical Study)

TS 제진공법으로 내진보강된 철근콘크리트 골조의 내진성능(Part 2:해석적 연구)

  • Received : 2018.01.10
  • Accepted : 2018.01.26
  • Published : 2018.03.01

Abstract

In this study, the nonlinear time history analysis of seismic retrofitted structures with TS damper for seven ground motion records was conducted for the purpose of verifying the seismic strengthening effect of TS seismic retrofitting method. Through comparison of the interstory drift ratio and the energy dissipation amount of the non - reinforced structure obtained and those of retrofitted structures with TS damper from the nonlinear time history analysis, the interstory drift ratio was reduced by about 30% and the amount of energy dissipation through the structure was halved. As a result, it was confirmed that the damping performance of the TS seismic retrofitting method is excellent.

본 연구에서는 TS 내진보강공법의 내진보강 효과 검증을 목적으로 7개의 지진파에 대한 TS 댐퍼(Tension Spring-Damper)로 내진보강된 구조물의 비선형 시간이력해석을 수행하였다. 비선형 시간이력 해석을 통해 얻어진 무보강 구조물의 층간변위비와 에너지소산 양과 비교한 결과 층간변위비가 약 30% 가량 감소하였고, 구조체를 통한 에너지 소산의 양은 반감되었다. 이를 통해 TS 내진보강공법의 제진성능이 우수함을 확인하였다.

Keywords

References

  1. An, T. S. (2014), Seismic performance of structures installed with cantilever-type steel dampers, Korea University, Seoul, Korea.
  2. Architectural Institute of Korea (2016), Korean Building Code-Structure, KBCS, Architectural Institute of Korea, 220-221.
  3. Computers and Structures Inc. (2006), PERFORM Components and Elements for PERFORM 3D and PERFORM-Collapse ver 4, CSI, Berkeley, CA.
  4. FEMA (2000), Prestandard and Commentary for the Seismic Rehabilitation of Buildings, Federal Emergency Management Agency, Washington D.C.
  5. Lee, C. H. (2015), Structural performance of SAFE dampers combining shear-type friction damper and non-uniform steel strip damper, Korea University, Seoul, Korea.
  6. Lee, S. J., Park, J. Y., Oh, S. H., and Yoon, Y. H. (2003), The Structural Behavior of the Braced-Frame System with Slit-plate Dampers, Proceedings of Autumn Annual Conference of the Architectural Institute of Korea, Architectural Institute of Korea, Seoul, 133-136.
  7. Ministry of Land, Transport and Maritime Affairs (2013), Assessment criteria for existing facilities (buildings) seismic performance evaluation, Ministry of Land, Transport and Maritime Affairs, 104-107.
  8. Oh, S. H., and Chang, I. H. (2000), Experimental Study on Hysterestic Characteristic of Braced Framed with Slit Plate Damper, Architectural Institute of Korea, Proceedings of Autumn Annual Conference of the Architectural Institute of Korea, Architectural Institute of Korea, Seoul, 349-352.
  9. Oh, S. H., Kim, Y. J., Ryu, H. S., Choi, H. B., and Kang, C. H. (2005), Hysteresis Behavior of Beam-to-Column Connections with Elasto-Plastic Hysteretic Dampers In order to reduce the carbon dioxide exhaust, Proceedings of Autumn Annual Conference of the Architectural Institute of Korea, Architectural Institute of Korea, Seoul, 635-638.
  10. Park, J. Y. (2009), Seismic performance of non-seismic RC frames retrofitted with steel dampers, Chung-ang University, Seoul, Korea.