• Title/Summary/Keyword: 병원 환자 관리시스템

Search Result 213, Processing Time 0.025 seconds

Quality Assurance of Intensity Modulated Radiation Therapy: Site-Specific Results of Eulji University Hospital (질환별 세기조절방사선치료의 정도관리: 을지대학병원 임상결과)

  • Kim, Sung-Jin;Lee, Mi-Jo;Youn, Seon-Min
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.99-106
    • /
    • 2011
  • Purpose: To analyze our quality assurance (QA) data for intensity modulated radiation therapy (IMRT) according to treatment site and to possibly improve QA for IMRT in Hospital. Materials and Methods: We performed QA on 50 patients (head and neck, 28 patients; Breast, 14 patients; Pelvis, 8 patients) for IMRT. The calculated dose from RTP was compared with the measured value film, gamma index, and ionization chamber for dose measurement in each case. Results: The point dose measurement results in 45 of 50 patients showed good agreement with the calculation dose (${\pm}3%$). The largest error measured thus far has been 3.60%, with a mean of only -0.17% (SD, 2.25%). Each treatment site showed an error rate of -0.13% (SD, 1.93%) for head and neck cases, -0.26% (SD, 2.79%) for breast cases, and 0.24% (SD, 2.44%) for pelvis cases. The gamma index verified with the error rate of head and neck cases (6%), breast (10%), and pelvis (6%), which corresponded to a tolerance of 3 mm (3% for the head and neck, 2%, for the breast 1% for the pelvis, and 0% in the region where the isodose curve was greater than 90%. Conclusion: We recognize the cause of errors for each treatment site of IMRT QA and so we maximize our efforts to reduce error and increase accuracy.

Satisfaction Evaluation of Diabetic Foot Disease Measurement using AI-based Application (AI기반 에플리케이션을 활용한 당뇨병성 족부질환 측정의 만족도 평가)

  • Hyeun-Woo Choi;Hyo-jin Lee;Min-jeong Kim;Jong-Min Lee;Dong-hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.327-334
    • /
    • 2024
  • The purpose of this study is to develop a customized foot disease analysis and management system for diabetic patients to prevent foot ulcers in diabetic foot disease patients. This system utilizes image analysis technology to measure not only foot pressure, but also ankle deformation, body balance, and foot wounds. Through various data, it is possible to accurately analyze the state of foot deformation, and based on this, the exact state of deformation of the foot of a patient with diabetic foot disease was identified and a customized insole was produced. This study was conducted to examine the satisfaction level of using an application that checks the status of diabetic foot disease wounds and to identify the degenerative status of diabetic foot disease patients and foot disease patients by wearing customized insoles and to survey the satisfaction of wearing insoles. As a result of the study, the knee angle measured for plantar pressure was -0.8 ± 1.3 degrees and ranged from a minimum of -2.4 degrees to a maximum of 1.1 degrees, and there was no significant difference in valgus knee between both lower extremities (p = 0.534). There was a significant difference in tibial angle between both lower extremities (p < 0.001). Ankle angle on the left side was 2.6 ± 2.0 degrees, ranging from a minimum of 0 degrees to a maximum of 6.3 degrees, and on the right, it was 4.5 ± 2.1 degrees, with a distribution of minimum 1.5 degrees to a maximum of 9.1 degrees. There was a significant difference in ankle angle between both lower extremities (p = 0.011). They responded that they felt an average of 4.3 points of satisfaction with the plantar pressure measurement application. Respondents responded that they felt an average of 3.9 points of satisfaction with the use of customized insoles.

The Development and Implementation of Ward Monitoring Service Using Bluetooth Low Energy Scanners for Infectious Disease Response (감염병 대응 비콘 스캐너 기반의 병실 모니터링 서비스 개발)

  • Lee, Kyu-Man;Park, Ju-young
    • Journal of Digital Convergence
    • /
    • v.15 no.3
    • /
    • pp.287-294
    • /
    • 2017
  • This study attempted to develop a beacon scanner based ward monitoring service in order to respond to the new paradigm of medical environment which is trying to introduce ICT technology as medical service to track and manage the spread path of large infectious diseases such as MERS. The study also included beacon hardware development, firmware development for the beacon low-power bluetooth 4.0, and server and web-based dashboard UI development. Using these, we have developed a customized monitoring system that provides functions such as locating patients by location based service and monitoring based on web UI. It is possible to maximize the efficiency of offline hospital services and to value active infection control and patient safety by integrating online technology into the area where online technologies such as beacons are not properly integrated.

Home Health Care Service Using Routine Vital Sign Checkup and Electronic Health Questionnaires (주기적인 생리변수 측정과 전자건강설문을 이용한 재택건강관리서비스)

  • 박승훈;우응제;이광호;김종철
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.469-477
    • /
    • 2001
  • In this Paper. we describe a home health care service using electronic health questionnaires and routine checkup of vital signs Including ECG (Electrocardiography) , blood pressure. and SpO$_2$ (Oxygen Saturation) . This system is for patients at home with chronic diseases, discharged Patients, or any normal people for the Prevention of disease The service requires a home health care terminal and a PC with Interned connection installed at Patient home. The distance health care management center is equipped with a vital-sign and questionnaire interpreter as well as database, Web, and notification servers with UMS (Unified Messaging System). Participating Physician can access the servers at the center using a Web browser running on a PC available to them at any time. These components are linked together through various kinds of data and voice communication channels including PSTN (Public Switched Telephone Network) . CATV(Community Antenna TV) . Interned. and mobile communication network. Following the Physician's direction given to a Patient. he or she uses the home health care terminal to collect vital signs and fill out the questionnaire. When the terminal automatically transmits these data to the management center. the data interpreter and servers at the center process the information fo1lowing the Protocol implemented on the system. Physicians can retrieve and review data corresponding to their Patients and send back their diagnostic reports to the center. UMS at the center delivers the physician 's recommendation to the corresponding patient through the notification server. Patients can also reprieve and review their own records as well as diagnostic reports from physicians. The system Provides a new way of collecting diagnostic information and delivering doctor's recommendation to patients at home for their health management. Future works are needed in the development of new technology for measurements and interpretations of various vital signs .

  • PDF

Comparison of F-18 FDG Radioacitivity to Determine Accurate Dose Calibrator Activity Measurements (방사능 측정기를 이용한 F-18 FDG 방사능의 비교)

  • Jin, Gye-Hwan;Kweon, Dae-Cheol;Oh, Ki-Baek;Park, Hoon-Hee;Kim, Jung-Yul;Park, Min-Soo;Park, Dae-Sung
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.159-166
    • /
    • 2009
  • Obviously, the administration of the prescribed amount of activity to the patient requires proper operation of the dose calibrator, which shall be verified by implementing the required quality control on the instrument. This investigation examined the accuracy and precision of dose calibrator activity measurement of the radiopharmaceutical F-18 FDG. To investigate the status of the nuclear medicine centers in Korea for the performance of dose calibrators, 10 centers providing PET/CT system services in Korea were inspected in 2008. We measured accuracy and precision in 10 equipments in consideration of PET/CT model, installation area, and installation time. According to the results of comparative analysis of 10 dose calibrators used to measure radioactivity of F-18 FDG, accuracy was -5.00~4.50% and precision was 0.05~0.45%, satisfying the international standards, which are accuracy ${\pm}$10% and precision ${\pm}$5%. This study demonstrated that, for accurate measurements, no adjustment is necessary for a dose calibrator setting when measuring different dose calibrators of F-18 FDG activity prescriptions.

  • PDF

Frequency of Candida Strains Isolated from Candidiasis Patients at A Tertiary Hospital over the Last 10 Years (최근 10년 동안 일개 상급종합병원의 칸디다혈증 환자에서 분리된 칸디다 균종의 빈도)

  • Hwang, Yu-Yean;Kang, On-Kyun;Park, Chang-Eun;Hong, Sung-No;Kim, Young-Kwon;Huh, Hee-Jae;Lee, Nam-Yong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.2
    • /
    • pp.110-118
    • /
    • 2022
  • Candidemia is a major cause of nosocomial infections resulting in increased morbidity and mortality. It remains a serious risk in inpatients and increases medical treatment costs. From 2009 to 2018, Candida strains (3,533) isolated from blood culture tests at the S Hospital were analyzed according to the period, year, sex, age, ward, etc. During the entire period, 54,739 of 717,996 blood culture tests showed a positive rate (7.6%) and the Candida isolation rate was 3,533 (6.4%) out of 1,036 patients. Among the Candida isolates, C. albicans was most common (33.8%), followed by C. tropicalis (28.6%), C. glabrata (19.8%), C. parapsilosis (7.8%), and C. krusei (4.0%). In early (2009~2013)/late (2014~2018) isolation, C. tropicalis decreased by 3.8% and C. glabrata increased by 3.4%. After 50 years of age, the higher the separation frequency. C. parapsilosis (31.3%) in 1~10s, C. tropicalis (30.3%) and C. glabrata (27.6%) in 41~50s, and C. tropicalis (28.6%) in 80s are relatively frequent. has been separated C. krusei was isolated in a relatively high proportion from females (60.9%). Therefore, a systematic and continuous nosocomial infection control system should be established for appropriate treatment as per antifungal treatment guidelines. The system should continuously monitor the distribution of Candida species and provide rapid identification results.

Development of MRI Simulator Early Diagnosis Program for Self Learning (자가 학습을 위한 MRI Simulator 초기 검사 프로그램 개발)

  • Jeong, Cheon-Soo;Kim, Chong-Yeal
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.403-410
    • /
    • 2015
  • Since 1970, MRI has greatly been developing in terms of strength of magnetic field, the number of receipt channels, and short time of examination. With the development of digital systems and wireless network, hospitals have also acquired, saved, and managed digital images taken by various kinds of medical imaging equipment. However, domestic universities fail to provide practice training course independently thanks to expensive practice equipment and high maintenance cost, and rely on clinical training. Therefore, this study developed a MR patient diagnosis program based on Windows PC to help out students before their working in clinical filed. The designed Relational Database of MRI Simulator is made up of seven tables according to functions and data characteristics. Regarding the designed patient information, each stepwise function was classified by the patient registration method in clinical field. In addition, on the assumption of the basic information for diagnosis, each setting and content were classified. The menu by execution step was arrayed on the left side for easy view. For patient registration, a patient's name, gender, unique ID, birth date, weight, and other types of basic information were entered, and the patient's posture and diagnosis direction were set up. In addition, the body regions for diagnosis and Pulse Sequence were listed for selection. Also, Protocol name and other additional factors were allowed to be entered. The final window was designed to check diagnosis images, patient information, and diagnosis conditions. By learning how to enter patient information and change diagnosis conditions in this program, users will be able to understand more theories and terms learned in practice and thereby to shorten their learning time in actual clinical work.

Caring Experiences of the Nurses Caring for Foreign Inpatients of non-English Speaking (비영어권 외국인 입원환자를 돌보는 간호사의 경험)

  • Jang, Hye-Young;Lee, Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.415-426
    • /
    • 2016
  • With a rapidly increasing number of foreign patients in Korea, it is necessary to manage and enhance the quality of nursing care for foreign inpatients through the promotion of studies on practical nursing care experience. This study is a qualitative study conducted to understand and describe the care experiences of nurses responsible for non-English speaking foreign inpatients. There were 10 nurses with a clinical career of more than two years included in this study for analysis. Data were collected through in-depth individual interviews and analyzed using qualitative content analysis. Five themes emerged from the analysis. 'Aware of cultural differences', 'establish trusting relationships through all my heart', 'additional nursing task', 'empathy for genuine nursing', 'sorriness and relieved'. The results of this study provided the understanding on the experiences of nurses, who do not speak English, but still responsible for providing care to foreign inpatients. Despite the language barrier, cultural differences, and work overload, nurses caring for foreign patients struggled with authenticity in nursing. On the other hand, as there was a lack of system resources, such as manuals and training materials in various languages other than English, institutions should put forth greater effort and resources to be prepared to care for foreign inpatients.

A Design & Implementation of Remote Access Function for A Multimedia Database of The Tele-medical System Based on ATM/B-ISDN (ATM/B-ISDN 기반의 원격 의료정보 시스템을 위한 멀티미디어 데이터베이스 원격 접속기능 설계 및 구현)

  • 김호철;김영탁
    • Journal of Korea Multimedia Society
    • /
    • v.1 no.1
    • /
    • pp.98-108
    • /
    • 1998
  • In the multimedia tele-medical system the medical informations are stored and managed in multimedia database. Also, multimedia DBMS is essential in order to manage large scale medical informations, and the remote access function is necessary for the distributed processing at all around the hospital. For the multimedia tele-medical information that is composed of image/picture, data, video, and audio, a high-speed telecommunication network is necessary that can provide separated connections for each medical information type with different QoS. The commercial DBMSs are based on the TCP/IP socket API(Application Programming Interface) that does not provide multiple QoS. Also, each commercial DBMS has its own API that is incompatible with other DBMS. In this paper, we propose a multimedia DBMS agent for the remote access of the multimedia database in the tele-medical system. The proposed multimedia DBMS agent is based on the ATM API that can provide high-speed data transfer capability and multiple QoS connections. Also, the proposed multimedia DBMS agent is independent of the commercial DBMS. We explain the functional architecture of the multimedia DBMS agent, implementation technology on the ATM network environment, and the result of performance analysis.

  • PDF

Utilization of and Satisfaction with Smart Bedside Station System as a Patient-centered Healthcare System (일 병원의 환자중심 지능형 병상 지원(Smart Bedside Station) 시스템의 이용현황 및 사용 만족도)

  • Cho, Moon Suk;Park, Yeon-Hwan
    • Journal of muscle and joint health
    • /
    • v.24 no.2
    • /
    • pp.89-100
    • /
    • 2017
  • Purpose: The aim of this study was to examine the utilization of and satisfaction with the smart bedside station (SBS) system among users in a hospital. Methods: A cross-sectional descriptive design was used. The participants were 190 patients, 186 family caregivers, and 154 nurses in a hospital. Results: Around 78.1% of patients or family caregivers used the SBS system at least once during their hospital stay. The commonly used items on the SBS system menu were "lab findings", "hospital cost", "today's medication", and the "alarm message". Satisfaction with the SBS system of patients and family caregivers were significantly higher than those of nurses (F=39.88, p<.001). Conclusion: A patient-centered SBS system was a useful system that could increase patient satisfaction and comfort. More specific and technical service contents reflecting the current healthcare system should be added.