1 |
Kaurin DG, Maryanski MJ, Duggan DM, Morton KC, Coffey CW. Use of MRI based polymer gel dosimetry, pelvic phantom, and cirtyal simulation to verify set-up and calculated three-dimensional dose distribution for a prostate treatment. In: Proceedings of the 1st International Workshop on Radiation Therapy Gel Dosimetry; Lexington, KY, USA; 1999. 184-186
|
2 |
Mayer R, Williams A, Frankel T, et al. Two-dimensional film dosimetry application in heterogeneous materials exposed to megavoltage photon beams. Med Phys 1997;24:455-460
DOI
ScienceOn
|
3 |
Que W, Kung J, Dai J. 'Tongue-and-groove' effect in intensity modulated radiotherapy with static multileaf collimator fields. Phys Med Biol 2004;49:399-405
DOI
ScienceOn
|
4 |
Vieira SC, Kaatee RS, Dirkx ML, Heijmen BJ. Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device. Med Phys 2003;30:2981-2987
DOI
ScienceOn
|
5 |
Low DA, Harms WB, Mutic S, Purdy JA. A technique for the quantitative evaluation of dose distributions. Med Phys 1998;25:656-661
DOI
ScienceOn
|
6 |
Low DA, Mutic S, Dempsey JF, et al. Quantitative dosimetric verification of an IMRT planning and delivery system. Radiother Oncol 1998;49:305-316
DOI
ScienceOn
|
7 |
Low DA, Dempsey JF. Evaluation of the gamma dose distribution comparison method. Med Phys 2003;30:2455-2464
DOI
ScienceOn
|
8 |
Depuydt T, Van Esch A, Huyskens DP. A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation. Radiother Oncol 2002;62:309-319
DOI
ScienceOn
|
9 |
Park DH, Shin D, Park SY, et al. Optimized matching of film dosimetry with calculated doses for IMRT quality assurance. Phys Med 2007;23:49-57
DOI
ScienceOn
|
10 |
Ezzell GA, Burmeister JW, Dogan N, et al. IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys 2009;36:5359-5373
DOI
ScienceOn
|
11 |
Xing L, Chen GT. Iterative methods for inverse treatment planning. Phys Med Biol 1996;41:2107-2123
DOI
ScienceOn
|
12 |
Bortfeld T, Boyer AL, Schlegel W, Kahler DL, Waldron TJ. Realization and verification of three-dimensional conformal radiotherapy with modulated fields. Int J Radiat Oncol Biol Phys 1994;30:899-908
DOI
ScienceOn
|
13 |
Chui CS, LoSasso T, Spirou S. Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multileaf collimations. Med Phys 1994;21:1237-1244
DOI
ScienceOn
|
14 |
Bortfeld T. IMRT: a review and preview. Phys Med Biol 2006;51:R363-R379
DOI
ScienceOn
|
15 |
Shin KH, Park SY, Park DH, et al. Patient specific quality assurance of IMRT: quantitative approach using film dosimetry and optimization. J Korean Soc Ther Radiol Oncol 2005;23:176-185
|
16 |
Yoon SM, Yi BY, Choi EK, Kim JH, Ahn SD, Lee SW. Quality assurance of patients for intensity modulated radiation therapy. J Korean Soc Ther Radiol Oncol 2002;20:81-90
|
17 |
Cho BC, Park SW, Oh DH, Bae H. Quality assurance for intensity modulated radiation therapy. J Korean Soc Ther Radiol Oncol 2001;19:275-286
|