• Title/Summary/Keyword: 병원 건물

Search Result 99, Processing Time 0.03 seconds

Hazard Distance from Hydrogen Accidents (수소가스사고의 피해범위)

  • Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.1
    • /
    • pp.15-21
    • /
    • 2012
  • An analysis was completed of the hazards distance of hydrogen accidents such as jet release, jet fire, and vapor cloud explosion(VCE) of hydrogen gas, and simplified equations have been proposed to predict the hazard distances to set up safety distance by the gas dispersion, fire, and explosion following hydrogen gas release. For a small release rate of hydrogen gas, such as from a pine-hole, the hazard distance from jet dispersion is longer than that from jet fire. The hazard distance is directly proportional to the pressure raised to a half power and to the diameter of hole and up to several tens meters. For a large release rate, such as from full bore rupture of a pipeline or a large hole of storage vessel, the hazard distance from a large jet fire is longer than that from unconfined vapor cloud explosion. The hazard distance from the fire may be up to several hundred meters. Hydrogen filling station in urban area is difficult to compliance with the safety distance criterion, if the accident scenario of large hydrogen gas release is basis for setting up the safety distance, which is minimum separation distance between the station and building. Therefore, the accident of large hydrogen gas release must be prevented by using safety devices and the safety distance may be set based on the small release rate of hydrogen gas. But if there are any possibility of large release, populated building, such as school, hospital etc, should be separated several hundred meters.

A Survey on the Sanitary Management in Food Service Institutions (집단급식소의 위생관리에 대한 실태 조사)

  • Soh, Gowan-Soon;Kim, Yong-Suk;Shin, Dong-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.1
    • /
    • pp.63-75
    • /
    • 2007
  • A survey on sanitary management at 98 food service institutions located in Jeollabuk-Do were conducted. Food service institutions included 13 hospitals, 38 schools, 40 enterprises, and 7 others. The sterilization in boiling water was used for disinfection of tableware, spoon and chopsticks, and dish towel. Cooking kit, refrigerator, chopping board, and knife were sterilized with disinfectant. Frequency of sanitary training program on employees was 56.1% for 1 time/month, 12.2% for 2-3 times/month, and 11.3% for 1 time/week. Preparing ratio of defrosting, warehouse and rest room, and washing and sterilization diary were 73.8, 60.5, and 54.5%, respectively. However, checking ratio of environments (9.5%), personal sanitation (10.8%), and sanitary training program diary(8.4%) were low. Major obstacle factors on the introduction of Hazard analysis critical control point (HACCP) system into food service institutions were lack of equipment and facilities (54.1%) and lack of understanding and data on HACCP system (17.3%). Therefore, in order to reduce the outbreak of food-borne diseases increasing frequency, we estimated that the introduction of sanitary management system and the conversion of dietician' perception on sanitary managements in food service institutions were needed.

A Mycological Survey in Indoor Environments (건물(建物) 환경(環境)의 진균(眞菌) 분포(分布) 조사(調査))

  • Kwon, Sook-Pyo;Chung, Yong;Ichigawa, Eiichi
    • The Korean Journal of Mycology
    • /
    • v.12 no.4
    • /
    • pp.183-188
    • /
    • 1984
  • This paper was concerned with the investigation on the species of fungi detected in indoor environments. Mycological survey on the wall of buildings and houses in Seoul was performed from December 26, 1983 to February 11, 1984. The collected fungi with the sterilized cotton rod were caltivated and isolated in the Potato-Detrose Agar medium with chloramphenicol. The fungi detected in hospital were Cladosporium sp., Penicillium sp., Alternaria sp., Chaetomium sp. and others. The fungi detected in household were Penicillium sp., Alternaria sp., Aspergillus sp., Cladosporium sp., Rhizopus sp., Trichoderma sp. and others. The kitchen of household was more contaminated by fungi than the living room and others. In hospital, it was much contaminated by the same species of the aboves on the wall of lobby and refectory. As the above results were recognized, the higher humidity and the more poor ventilation, the more species and amount of fungi were contaminated. Further studies on the identification of pathogenic fungi should be continued. The proper regulation for the hygienic maintenance of indoor environment in household, hospital and other public buildings should be recommended as well.

  • PDF

A Study on the Linoleum of the Deoksugung and Changdeokgung Palaces in the Early 20th Century: focusing on its manufacturing process, characteristics, and usage (20세기 초 덕수궁·창덕궁에 유입된 리놀륨(Linoleum) 바닥재 연구: 리놀륨의 제작 방식과 특성 및 사용을 중심으로)

  • Choi, Jihye
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.1
    • /
    • pp.18-31
    • /
    • 2021
  • Linoleum is a resilient, hygienic, and eco-friendly floor covering. It was developed in England by Frederick Walton in 1863. Made of cork flour, linseed oil, and burlap as its main materials, the flexible and waterproof linoleum became globally popular in the early 20th century. Unlike the vinyl coverings, the burlap-backed linoleum was used not only in commercial spaces but also in household areas like kitchens, bathrooms, and even living rooms. As a global product, linoleum was imported and used in Korean palaces like Deoksugung and Changdeokgung in the early modern period. According to the record Deoksugung Won-Ahn, linoleum was applied to the major buildings, including Hamnyeongjeon, Deokhongjeon, and Jeonggwanheon, and various other venues. The linoleum used in these places are mainly monochrome blue and brown color, which probably means that they are from England. The trade records in the early 20th century show that linoleum was imported mainly from England and America. The Ewangjik building floor plan in the Changdeokgung Palace shows that linoleum was used extensively. There are even some originals, which were laid in 1920 and left in the Changdeokgung Palace. When Daejojeon and Huijeongdang were rebuilt in 1920, the interior was outfitted with western features and linoleum was used in areas such as bathrooms, the tonsorial parlor, and one of the rooms on the west side of Huijeongdang. In situ in the Daejojeon and Huijeongdang areas in the Changdeokgung Palace are monochrome, patterned black, and stylized floral tile patterned, which are closely similar to American products made by ALC and Armstrong company. This study will help us better understand linoleum's characteristics, its uses and the material itself. It will also form the basis for the restoration of Changdeokgung Palace as well as other modern interiors with linoleum flooring in the future.

A Study on the State of Convenience Facilities for the Accessibility of a Disabled Person in Dental Institutions in the City of Cheongju (청주시 소재 치과의료기관의 장애인 접근성 확보를 위한 편의시설 실태조사)

  • Lim, Soon-Ryun;Kim, Sun-Ju
    • Journal of dental hygiene science
    • /
    • v.11 no.3
    • /
    • pp.235-241
    • /
    • 2011
  • The purpose of this study was to examine the state of convenience facilities for the disabled in dental institutions in an effort to provide some information on the improvement of the accessibility of disabled people to dental institutions. A survey was conducted on the licensed dental institutions in the city of Cheongju, North Chungcheong Province, from March to April, 2011. The findings of the study were as follows. The dental offices were the majority of the dental institutions investigated, and for the establishment of the dental institutions. Some of the offices were established before 1990, and some were established in 2011. The time period of establishment varied within the offices. As for the location of the dental institutions within the buildings, they were mostly on the second or third floor. Regarding the convenience facilities for the disabled, the most installed convenience facilities were boardwalks and elevators, and the least installed ones were parking lots and restrooms for the disabled. The hospitals and public dental centers were equipped with all the convenience facilities investigated in this study. Overall, the dental institutions that were established in and after 2006 were equipped with more convenience facilities than the dental institutions that were established before 1990. And the dental clinics that were on the third or higher floor were more equipped with elevators and outdoor slope ways than those that were on the first or second floor. Therefore the revision of the law is required to urge even the primary dental institutions to compulsorily install the convenience facilities. The findings of the study are expected to make a contribution to the improvement of the accessibility of disabled people to dental institutions.

Ecological Studies on Lettuce Drop Disease Occurring under Controlled Cultivation Conditions in Drained Paddy Fields (답리작 상치 시설재배지에서의 균핵병 발생생태에 관한 연구)

  • Shin Dong Bum;Lee Joon Tak
    • Korean Journal Plant Pathology
    • /
    • v.3 no.4
    • /
    • pp.252-260
    • /
    • 1987
  • Incidence of lettuce drop was observed throughout the growing season in the vinylhouse at the southern part of Korea, Kimhai. Occurrence of this disease was especially severe at the seedling stage. Number of sclerotia in surface soil $(30\times30\times5cm)$ was 22.0 at the seedling stage, and 5.3 at harvest in the infected area. Temperature for mycelial growth ranged from 5 to $30^{\circ}C$ with optimum temperature at $25^{\circ}C$. Sclerotia were formed fewer at low temperature, but their size was larger resulting in heavier dry weight than that at high temperature. The apothecia were formed from the sclerotia that were buried in March, April and September upto 3cm soil depth, but formed from those buried only 1 em soil depth in October. Sclerotia buried in June and December did not form apothecia regardless of soil depth by 90 days. The sclerotia buried in the 5cm of soil depth did not form apothecia. Sclerotia that were embedded in wet or flooded soil at $25^{\circ}C$ and $30^{\circ}C$ for 5 weeks lost their viability. Infection of lettuce was possible with mycelia originated from sclerotia on autoclaved lettuce plant fragments. The fungus was pathogenic on 25 plant species in 8 families in artificial inoculation tests. Lettuce seedlings appeared to be infected by airborne ascospore originated from sclerotia on crops and weeds around paddy fields, because sclerotia existing in soil might perish under long flood conditions during rice cultivation.

  • PDF

Occurrence of Sclerotinia Rot on Perilla Caused by Sclerotinia sclerotiorum under Structured Cultivation Condition (Sclerotinia sclerotiorum에 의한 시설재배 들깨 균핵병 발생특성)

  • Shin, Dong-Bum;Song, Seok-Bo;Moon, Byung-Ju
    • Research in Plant Disease
    • /
    • v.12 no.3
    • /
    • pp.158-163
    • /
    • 2006
  • Sclerotinia rot caused by Sclerotinia sclerotiorum frequently causes serious and unpredicable yield losses of the leaves of perilla growing under structured cultivation as vegetable in Korea. Temperature for mycelial growth ranged from 5 to $30^{\circ}C$ with optimum temperature d $20^{\circ}C$. Sclerotia were formed fewer at low temperature, but their dry weight was heavier than that at high temperature. The apothecia were formed from the sclerotia that buried up to 3 cm soil depth at $15^{\circ}C$ in moisture condition. The incidence of perilla Sclerotinia rot caused by S. sclerotiorum was observed throughout the growing season at greenhouse. The occurrence of this disease was especially severe from January to February of low temperature period. The average incidence rates of this disease was up to 15%. The significant occurrence of this disease was showed mainly in the continuous cropping field for more than five years. The incidence of this disease increased according to the increase of continuous cropping year. The incidence rates of this disease reached up to 20% in the continuous cropping field for ten years. Also it was firstly investigated the natural infection caused by S. sclerotiorum on weed plants, Gnaphalium affine and Mazus pumilus in farmer's field. The casual fungus showed pathogenicity on 11 weed plants species tested, and more severe pathogenicity on G. affine, Latuca indica and Ixeris dentata included in the family Compositae. This result suggests that effective crop rotation and weed eradication can be the method for organic control of perilla sclerotinia rot, and sudden outbreaks of this disease on perilla growing under structure after paddy rice call be explained by the presence of weed hosts.

A Study on Fire and Evacuation simulation analysis for use of Disaster Vulnerable Personal Evacuation Device (재난약자 대피 도움장치 활용을 위한 화재 피난 시뮬레이션 분석 연구)

  • Choi, Doo Chan;Hwang, Hyun Soo;Ko, Min Hyeok;Lee, Si Yu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.824-831
    • /
    • 2020
  • Purpose: In fire case, nursing hospitals are subject to considerable restrictions on evacuation due to the characteristics of occupants and vulnerable elements of buildings, it is important to make evacuation device for vulunerabale person, and need how to intend to increase the efficiency of evacuation by fire and evacuation simulation with helper Method: The smoke characteristics were analyzed by time through fire simulation, finally, the number of helpers according to the day and night was entered, and the evacuation completion time was compared and analyzed using the evacuation simulation. Result: It was found that the evacuation time was shortened by more than 20% when the evacuation assistance device was used for the vulnerable, and the evacuation time was delayed by almost 70% in case of a fire at night compared to the daytime. Conclusion: If the horizontal and vertical evacuation device are effectively utilized in actual fire situations, a strategy appropriate to the situation is deemed necessary. It is expected that evacuation efficiency will increase based on the use of horizontal evacuation evacuation device and vertical evacuation device by developing evacuation manuals

Performance Analysis of Cooling Tower-Assisted Hybrid Ground-Coupled Heat Pump (HGCHP) System (냉각탑 병용 하이브리드 지열 히트펌프 시스템의 성능 분석)

  • Sohn, Byonghu;Lee, Doo-Young;Choi, Jae-Ho;Min, Kyong-Chon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.19-26
    • /
    • 2016
  • This paper presents the measurement and analysis results for the performance of HGCHP system using a cooling tower as a supplemental heat rejector. In order to demonstrate the performance of the hybrid approach, we installed the monitoring equipments including sensors for measuring temperature and power consumption, and measured operation parameters from February 1, 2014 to February 28, 2015. Leaving load temperatures to building showed an average value of $11.7^{\circ}C$ for cooling and $39.5^{\circ}C$ for heating, respectively. From the analysis, the daily PF of hybrid GCHP system varied from 2.6 to 6.6 over the measurement period.

Isolation of the Legionella Species from Specimens of Cooling Tower Water (환경수(냉각탑수)로 부터 Legionella속 균의 분리)

  • Chung, Jong-Hak;Kang, Pock-Soo;Kim, Seok-Bhum;SaKong, Jun
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.77-84
    • /
    • 1988
  • The principal mode of the transmission of Legionnaires disease is a inthalation of the cooling tower water droplets in which Legionellae exist. As a central cooling system is popularized in many public buildings and large buildings nowadays, the number of cooling towers is rapidly increasing. Therefore the possibility of an outbreak of Legionnaires disease is likely increased. To determine the presence of Legionella in cooling tower water as the first step for the prevention of Legionnaires disease, 48 samples of cooling tower water were taken from 24 buildings in Taegu city in july and september 1987. Three samples out of 24 water samples In September yielded Legionella but it was not isolated in the samples of July. Isolated 3 Legionellas were identified as Legionella peumophila. It seems that Legionella from the cooling tower will be isolated more frequently in late summer than early because central cooling system is stopped operation during winter season which is cool. As based on our survey, Legionnaires disease can occur in Taegu city and if it happens it is most likely due to L. pneumophila.

  • PDF