• 제목/요약/키워드: 밸리데이션

Search Result 48, Processing Time 0.026 seconds

ELISA Validation for anti-PA Antibody Titer Measurements (항-보호항원 항체의 역가 측정을 위한 효소면역측정법 밸리데이션)

  • Kim, Yu-Gene
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.478-485
    • /
    • 2010
  • The vaccine is biological pretreatment that improves immunity to a particular disease. We can get immunity from producing antibody with injection antigen which has ability to defense against the disease. The ELISA is the most widely used method to measure antibody titer. We have developed and performed validation of ELISA according to the guideline of KFDA and ICH. In this paper, we have verified ELISA method is an excellent method to measure the titer of anti-PA antibody. We have constructed recombinant protective antigen among anthrax toxins and used as antigen of ELISA. In this validation, we have evaluated precision (repeatability, interlaboratory precision), specificity, linearity(range) and LOD, which are validation articles suggested by guideline. Inter-person precision was replaced with inter-laboratory precision. From the results, we have confirmed high precision in all experiments with CV under 20%.

Isolation and HPLC-DAD validation of xanthoangelol in Lespedeza bicolor extract (싸리나무 추출물의 Xanthoangelol 분리 및 HPLC-DAD 밸리데이션)

  • Woo, Hyun Sim;Kim, Yeong-Su;Oh, Yu Jin;Cho, Hae Jin;Song, Se-Kyu;Kim, Dae Wook
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.1
    • /
    • pp.26-30
    • /
    • 2020
  • This study was undertaken to determine the characteristics of xanthoangelol, the major chalcone constituent derived from the extracts of different parts of Lespedeza bicolor. Xanthoangelol was isolated from the root extract using column chromatography and used as a standard for quantitative analysis. The structure of the isolated compound was established based on spectroscopic evidence. The HPLC-DAD method was validated for specificity, linearity, precision, accuracy, limit of detection, and limit of quantitation. The calibration curve of xanthoangelol had significant linearity (R2>0.9999). Limit of detection and limit of quantitation 0.018 and 0.059 ㎍/mL, respectively. The relative standard deviation values of precision test, and intra- and inter-day tests were less than 0.22 and 0.40%, respectively. In the recovery test, the accuracy ranged from 98.98-102.78% with RSD values less than 0.13%. The method validation parameters indicate the applicability of the HPLC method for quality control of food or drug formulations containing L. bicolor.

Establishment for analytical method of methanol in wet wipes by headspace gas chromatography (가스크로마토그래프-헤드스페이스를 이용한 물휴지 중 메탄올 정량법 확립 연구)

  • Choi, Yongkyu;Baek, Eunji;Min, Chungsik;Lee, Rheeda;Park, Soonyoung;Ahn, Jaehyung;Kim, Sangseop;Hong, Seonghwa;Kim, Younglim
    • Analytical Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.242-247
    • /
    • 2016
  • This research aims to set up and validate methods of analyzing the methanol in wet wipes and verifies the analysis methods that applied to the wet wipes. We used Headspace (HS) Gas Chromatography (GC) - Flame Ionization Detector (FID) to the establish analysis method of methanol in wet wipes and optimized heating temperature, heating time, GC conditions with column. The result indicated that 3 mL of sample in 20 mL headspace vial can be equilibrated efficiently in headspace sampler at 70 ℃ for 10 min and sample was measured by GC with spli injection mode(10:1). The results show that linearity from 1 to 100 ppm was over R2 0.9995, precision was RSD 1.83 % and accuracy(recovery rate) was 105.44 (±1.05 %) on water matrix and wet wipes matrix removed non-woven fabric. Also, monitoring results of total 20 cosmetics on the market, from 0.00017 to 0.00156 % of methanol was detected from wet wipes.

Development and validation of a HPLC method for the simultaneous determination of chlorquinaldol and promestriene in complex prescription (복방제제 내 클로르퀴날돌과 프로메스트리엔에 대한 HPLC 기반 동시분석법의 개발 및 밸리데이션)

  • Lee, Seul-Ji;Shin, Sang-Yeon;Shin, Hae-Jin;Lee, Jin-Gyun;Kim, Dong-Hwan;Lee, Su-Jung;Han, Sang-Beom;Park, Jeong-Hill;Lee, Jeong-Mi;Kwon, Sung-Won
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.152-157
    • /
    • 2012
  • Currently, many types of compound preparations are being used but the quality control guidelines for their use are lacking. In case of single compound drug, the quality control methods are specified in the pharmacopeia. However, there is no method to simultaneously analyze compound preparations. In this study, a simple validated analytical method for HPLC separation of chlorquinaldol and promestriene is introduced. Validation was divided into categories including linearity, precision, accuracy (recovery) and system suitability. The contents of the products which are on the market were monitored using the validated analytical method and the robustness of the analytical method was tested by conducting an inter-laboratory validation.

Validation of UPLC Analysis Method for Putrescine in Lyophilized Royal Jelly (동결건조 로열젤리 내 putrescine 함량 분석을 위한 분석법 밸리데이션)

  • Hong-Min, Choi;Se-Gun, Kim;Hyo-Young, Kim;Soon-Ok, Woo;Sang-Mi, Han
    • Korean journal of applied entomology
    • /
    • v.61 no.4
    • /
    • pp.659-664
    • /
    • 2022
  • Putrescine generated by the action of microorganisms in the decay generally used as a measure of freshment in food. However, the analytical method of putrescine in freeze-dried royal jelly has not yet been established. In the present study, the UPLC method for putrescine in lyophilized royal jelly was established using C18 column. The newly established method was able to analyze putrescine accurately within 7 minutes and was validated by analytical parameters such as specificity, linearity, precision, accuracy, limit of detection, and limit of quantification. These results provide for the analytical method to evaluate the level of freshment in freeze-dried royal jelly, which will useful in further studies of safety verification.

Antioxidant activities and Validation of Analytical Method of Marker compounds in strawberry fruits from various cultivars (딸기 품종별 추출물의 항산화활성 및 지표성분 밸리데이션)

  • Yong, Ye Seul;Lee, Songmi;Byun, Na-Young;Sun, Sangouk;Kim, Min-Jung;Jang, Seo Woo;Jang, Won Suk;Lee, Sun Yi;Yim, Soon-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.6
    • /
    • pp.517-523
    • /
    • 2019
  • In this study, we investigated antioxidant capacity of 20 strawberry extract using the DPPH and ABTS assay and HPLC-DAD validation method. The total polyphenolic and flavonoids contents of 20 strawberry extracts were 22.77-107.61 mg TAE/100 g FW and 17.58-44.12 mg QE/100 g FW. The Aiberry and Elie star showed the highest total polyphenol and flavonoid contents, respectively. The DPPH radical scavenging activity of what was 1540.6-1124.0 μmol TEAC/100 g FW and Derunoka showed the highest activity. The ABTS radical scavenging activity was 6352.3-4592.3 μmol TEAC/100 g FW and FA23 showed the highest activity. The HPLC-DAD method for the quantitation of ellagic acid results showed high linearity in various concentration ranges, and the limit of detection was 2.35 μg/mL. The limit of quantification was 7.12 μg/mL. Relative standard deviation values from intra-and inter-day precision were less than 5.31%. Recovery rate at 10, 50, and 100 μg/mL, respectively, were 100.0-101.0% with relative standard deviation (RSD) values less than 5.30%. These results provide viable information for the validation of antioxidant capacity in strawberry fruits.

Investigation of Validation Guidelines for Performance Verification of High Performance Liquid Chromatograph (고성능 액체크로마토그래프 기기의 성능검증을 위한 밸리데이션 가이드라인에 대한 연구)

  • Yun, Won Nam;Lee, Beom-Gyu;Lee, Wonjae
    • YAKHAK HOEJI
    • /
    • v.57 no.5
    • /
    • pp.362-368
    • /
    • 2013
  • High performance liquid chromatograph (HPLC) is the most frequently used analytical instrument in analytical laboratories for pharmaceutical analysis. In order to provide a high level of assurance for reliable data generated from the HPLC analysis, the performance qualification of the HPLC system is required. For this purpose, the performance of HPLC system should be regularly monitored by examining the key functions of the typical HPLC system (solvent delivery system, injector system, column oven, UV-VIS detector system). We have investigated the validation guidelines of the performance verification of these key modules for HPLC system. And we proposed and evaluated its validation guidelines and the related verification methods for pharmaceutical analysis that could be practically applied in Korea.

The Proposed Validation Guidelines and Their Application for Performance Verification of UV-VIS Spectrophotometer (UV-VIS 분광기기의 성능검증을 위한 밸리데이션 가이드라인의 제정 및 응용)

  • Jin, Jing-Yu;Kang, Young-Koo;Lee, Won-Jae
    • YAKHAK HOEJI
    • /
    • v.50 no.3
    • /
    • pp.154-159
    • /
    • 2006
  • For the increasing demand for the validation of analytical results, one of the important concerns of the analyst is to be assured that the instrumentation is working to qualified conditions. In this study, we have investigated and compared several validation guidelines of the performance verification of UV-VIS spectrophotometer used in pharmacopoeias of major countries and UV-VIS instrument analytical companies, and we proposed the practically useful validation guidelines of UV-VIS spectrophotometer. Based on our proposed validation guidelines of UV-VIS spectrophotometer, several UV-VIS spectrophotometers used in drug manufacturing laboratories were validated for their performances.

HPLC Method Validation for Quantitative Analysis of Scopoletin from Hot-Water Extract Powder of Artemisia annua Linné (기능성 원료 인정을 위한 제출자료 작성 가이드[민원인 안내서]에 따른 개똥숙 열수추출분말의 Scopoletin 분석을 위한 HPLC 분석법 밸리데이션)

  • Kim, Seon-Hee;Yoon, Kee Dong
    • Korean Journal of Pharmacognosy
    • /
    • v.51 no.1
    • /
    • pp.78-85
    • /
    • 2020
  • In this study, we shortly introduced the HPLC method validation guideline for the analysis of functional food which was released from the Ministry of Food and Drug Safety of Korea in Dec 2018. The HPLC method validation was performed through the aforementioned HPLC method validation guideline in order to quantitate scopoletin content from the hot-water extract powder of Artemisia annua Linné. The HPLC method was validated by evaluating specificity, accuracy, precision, limit of quantitation and linearity. All parameters were in the suitable ranges which are designated in the guideline, which indicated the current HPLC method is reliable to quantitate the scopoletin content from the hot-water extract of A. annua.

Isolation and Quantitative Determination Method Validation of myristicin from Myristica fragrans Houttuyn (육두구(Myristica fragrans Houttuyn) 내의 myristicin의 분리 및 HPLC를 이용한 함량분석 방법 밸리데이션)

  • Kim, Soo-Hwan;Lee, Dong-Ho;Kwon, Soo-Han;Lim, Buyng-Ho;Lee, Sang-Hun;Min, Bum-Chan
    • Korean Journal of Pharmacognosy
    • /
    • v.38 no.1
    • /
    • pp.19-21
    • /
    • 2007
  • Myristica fragrans has been used for the treatment of stomachache in East Asia. It is very important to determine the amount of myristicin in Myristica fragrans, because excess myristicin causes side effects. In this study, we developed and validated the method for determination contents of myristicin in Myristica fragrans which was purchased from various regions of Korea. The average content of myristicin in Myristica fragrans was 2.10% with the validated HPLC analysis method.