• Title/Summary/Keyword: 배연차

Search Result 28, Processing Time 0.028 seconds

A Study on the Application of a Exhaust Engine in Basement Karaoke Fires (지하 노래방 화재 시 배연차의 활용에 관한 연구)

  • Lee, Sung-Ryong
    • Tunnel and Underground Space
    • /
    • v.20 no.4
    • /
    • pp.277-283
    • /
    • 2010
  • In this study, an experiment was conducted to evaluate the effectiveness of a exhaust engine in a basement karaoke fire. Exhaust engine was used as ventilation equipment in the experiment. Experiment was carried out in a basement karaoke for redevelopment. Temperature distribution and smoke concentration were evaluated according to the operation of an exhaust engine. Temperatures were decreased below $50^{\circ}C$ at the corridor due to the operation of the exhaust engine. Visibility was also improved.

An Experimental Study on Mechanical Ventilation Using an Exhaust Engine in Corridor Fires (복도공간 화재 시 배연차를 활용한 배연에 관한 실험적 연구)

  • Lee, Sung-Ryong;Han, Dong-Hoon
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.99-105
    • /
    • 2010
  • Ventilation fans utilized correctly can increase the effectiveness of fire fighters and survivability of occupants. It is possible to increase the pressure of a corridor to prevent the infiltration of smoke. In this study, experiments were carried out to evaluate ventilation effectiveness in corridor fires. Corridor used in the experiment was 20 m long. Heptane was used as a fuel. Temperature and visibility were measured in order to evaluate ventilation effectiveness according to the position of a vent. Vent distance ranged from 0 m to 4 m and height varied from 0 m to 1.5 m. When the vent was positioned 2 m long and 0.75 m high the result was most effective.

Experimental study on the effect of exhaust ventilation by shafts for case of fire in long traffic tunnels (장대 교통터널 화재시 수직갱의 배연효과에 관한 실험적 연구)

  • Yoo, Yong-ho;Yoon, Chan-hoon;Yoon, Sung-wook;Kim, Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.1
    • /
    • pp.27-36
    • /
    • 2005
  • The objective of this study was to analyze the smoke movement and to investigate the effect of exhaust ventilation using by shafts for case of fire in long tunnels. Based on Froude modeling, the 1/50 scaled model tunnel (20 m long) was constructed by acrylic tubes and test were carried out systematically. The results of the shaft height test show that the effect on exhaust ventilation by a shaft delays the propagation time of backlayering, and the temperature decreases as the shaft height increases. If the fire occurs downstream of the shaft, the backlayering develops to get stronger by the shaft exhaust effect and then the propagation of CO and temperature increase along with propagation of CO. That is to say, in the case of fire downstream of the shaft, the shaft has the advantage of smoke exhaust effects, but it might result in a dangerous situation for the escaping passengers due to the more developed backlayering.

  • PDF

'Chosi', Early Maturing Sweet Persimmon (Diospyros kaki Thunb.) for 'Chuseok' (조생종 추석용 단감 '초시' 육성)

  • Ma, Kyeong-Bok;Cho, Kwang-Sik;Kang, Sam-Seok;Kim, Yoon-Kyeong;Hwang, Hae-Sung;Choi, Jang-Jeon;Han, Jeom-Hwa
    • Korean Journal of Breeding Science
    • /
    • v.51 no.4
    • /
    • pp.424-427
    • /
    • 2019
  • A persimmon (Diospyros kaki L. Thunb.) cultivar, 'Chosi', which was a cross between 'Johongsi' and 'Nishimurawase' in 2000, was finally selected in 2010. 'Chosi' persimmon fruits were harvested in Sept. 19 in Naju, with a medium fruit size of 161 g, on average, and high soluble solids of approximately 15.3 °Bx. The flesh tastes good, with a crispy texture, and the juice is rich. The shape of the fruit is round oblate, and the skin color is orange; the appearance is graceful. Physiological disorders, such as stylar-end cracking or skin fine cracking, rarely occur in this cultivar. (Registration No. 7075)

Study on Heat and Smoke Behavior Due to the Natural Wind and the Forced Smoke Ventilation for the Fire in an Underground Subway Station (지하역사에서 화재발생시 자연풍 및 강제배연의 유무에 따른 열 및 연기거동 특성 연구)

  • Chang Hee-Chul;Kim Tae-Kuk;Park Won-Hee;Kim Dong-Hyeon
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.80-86
    • /
    • 2005
  • In this study effects of the natural wind and the forced smoke ejection by operating the exhaust fan are studied numerically to examine the flow characteristics of the smoke and heat generated from a fire on the platform of an underground subway station. Three different situations, including 1) the case with no natural wind and no exhaust fan operation, 2) the case with natural wind but no exhaust fan operation and 3) the case with no natural wind but exhaust fan operation, are considered for the numerical analyses. The numerical results show that the natural wind causes a rapid spread of the fire along the tunnel resulting in rapid spread of the smoke and heat over the platform which affects the escape. The operation of the exhaust fan also results in the rapid spread of smoke and heat over the platform, but the time required for reaching the safe escaping height of the smoke layer with the exhaust fan operation is much longer than that without the exhaust fan operation. The numerical results also show that the required capacity of the exhaust fan becomes larger when the effect of the natural wind is included.

Experiments on the Influence of Opening of Natural Smoke Ventilators on the Stack Effect in High-rise Mixed-use Residential Buildings (초고층주상복합건물에서 배연창 개방이 연돌효과에 미치는 영향에 대한 실험적 연구)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Park, Yong-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.89-94
    • /
    • 2009
  • The stack effect in high-rise buildings is expected more significant at nights in winter due to the large temperature difference between the inside and outside of the buildings. However, the existence of large openings such as natural ventilators on the floor may effect the position of neutral plane, smoke spread at fire and thus obstruct the door openings for rescue. In this paper, the vertical and horizontal pressure distribution with different openings of natural smoke ventilators was experimentally analyzed by investigating pressure differentials.

Additive effects on $SO_x/NO_x$ removal characteristics using plasma (첨가제 활용에 따른 플라즈마 배연탈황탈질 특성)

  • 지평삼;엄희문;장경룡;남창모;지준화;한영욱
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.260-261
    • /
    • 1999
  • 산업시설 및 대형 발전설비에서 배출되는 아황산가스 및 질소산화물은 대기환경에 직접적으로 악영향을 미칠 뿐만 아니라, 오존의 생성과 고갈, 산성비의 출현등으로 지구 온난화와 같은 기후변화에 크게 기여하는 것으로 보고되고 있다. 기존의 습식 석회/석회석 탈황공정(FGD) 및 선택적 촉매/비촉매 탈질기술(SCR/SNCR)은 효과적인 상용기술로서 널리 연구개발되어 왔으나, 대단위 시설투자와 고비용, 2차 오염물질의 배출이 단점으로 지적되고 있다(Nam, 1999).(중략)

  • PDF

An analytical study on the fire characteristics of the small tunnel with large smoke exhaust port (대배기구 배연방식을 적용한 소형차 전용 터널의 화재특성에 관한 해석적 연구)

  • Yoo, Ji-Oh;Kim, Jin-Su;Rhee, Kwan-Seok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.375-388
    • /
    • 2017
  • In order to solve the traffic congest and environmental issues, small-cross section tunnel for small car only is increasing, but there is not standard for installation of disaster prevention facility. In this study, in order to investigate the behavioral characteristics of thermal environment and smoke in a small cross section tunnels with a large port exhaust ventilation system, the A86, the U-Smartway and the Seobu moterawy tunnel, Temperature and CO concentration in case of fire according to cross sectional area, heat release rate and exhaust air flow rate were analyzed by numerical analysis and the results were as follows. As the cross-sectional area of the tunnel decreases, the temperature of the fire zone increases and the rate of temperature rise is not significantly affected by heat release rate. However, there is a difference depending on the change of the exhaust air flow rate. In the case of applying the exhaust air flow rate $Q_3+2.5Ar$ of the large port exhaust ventilation system, the temperature of the fire zone was 7.1 times for A86 ($Ar=25.3m^2$) and 5.4 time for U-smartway ($Ar=37.32m^2$) by Seobu moterway tunnel ($Ar=46.67m^2$). The CO concentration of fire zone also showed the same tendency. The A86 tunnels were 10.7 times and the U-Smartways were 9.5 times more than the Seobu moterway. Therefore, in the case of a small section tunnel, the thermal environment and noxious gas concentration due to the reduction of the cross-sectional area are expected to increase significantly more than the cross-sectional reduction rate.

Manufacture and Application of anhydrous calcium sulfate from flue gas desulfurization gypsum (排煙脫黃石膏로부터 無水石膏 製造 및 適用 特性)

  • Hyun, Jong-Yeong;Jeong, Soo-Bok;Chae, Young-Bae;Kim, Byung-Su
    • Resources Recycling
    • /
    • v.14 no.2
    • /
    • pp.10-18
    • /
    • 2005
  • The manufacture property of anhydrous calcium sulfate (anhydrite Ⅱ) from flue gas desulfurization (FGD) gypsum discharged from domestic thermoelectric power plants to apply as an auxiliary material of cement and concrete by high temperature treatment were investigated. The FGD gypsum was completely converted to anhydrite Ⅱ at the temperature of 700$^{\circ}C$ and the retention time of 1 hr. In the phase transformation process, particle size was also changed. The chemical composition, particle size and heat property of anhydrite Ⅱ made from the FGD gypsum were similar to them of natural gypsum. In the leaching test of sulfate ion (SO$_4^{2-}$) at the temperature of 90$^{\circ}C$ and the retention time of 1 hr, the amount of leached SO$_4^{2-}$ for the anhydrite Ⅱ that was sintered at 700$^{\circ}C$ for 1 hr was about 50 wt.% based on that of natural gypsum. In addition, the amount of leached SO$_4^{2-}$ for the anhydrite Ⅱ by adding the slaked lime of 3 wt.% decreased about 70 wt.% comparing with that of natural gypsum. In the application test, the compressive strength of cement and concrete manufactured by using the anhydrite Ⅱ as an auxiliary material were similar or superior compared with them of cement and concrete done by natural gypsum as an auxiliary material.

Acquisition of Large Scale Geographical Information by Remote Control of Non-Metric Camera (비측정용 카메라의 원격조종에 의한 대축척 지형정보 획득)

  • Kang, Joon-Mook;Yoon, Hee-Cheon;Bae, Yeon-Soung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.1 no.2 s.2
    • /
    • pp.177-184
    • /
    • 1993
  • To obtain large scale precise geographical information in local area we determined external orientation parameters of camn exactly and conducted aerial photography using remote control airship loaded 35mm non-metric camera that produced systematic error coefficients. Ground control Points were determined by differential GPS. Therefore we can try to improve accuracy and economical efficiency. Also, it is suggested that remote control airship photogrammetry can be applied to make large scale topographic map using analytical plotter as calibrated accuracy.

  • PDF