• Title/Summary/Keyword: 배관 진동

Search Result 273, Processing Time 0.029 seconds

Vibration Reduction of Pump And Pipe System (대형펌프와 조합된 배관계 진동 저감)

  • Bae, Chun-Hee;Won, Jong-Bum;Cho, Cheul-Whan;Yang, Kyeong-Hyeon;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.652-657
    • /
    • 2000
  • In this paper, Firstly, it is shown that the high vibration source of piping system is the pulsation transmission of pipe line element, such as, orifice plate, valves and the control valve is a broad band source and the branch wall and the cavity have vortex frequency. Secondly, in order to decrese the high vibration of piping system, some practical Friction damper with high damping have been developed and its effectiveness is investigated as installing it at piping system practically.

  • PDF

Forced Vibration Analysis of Elastically Restrained Valve-pipe System (탄성지지된 밸브 배관계의 강제진동 특성)

  • Son, In-Soo;Yoon, Han-Ki;Min, Byoung-Hyun;Hur, Kwan-Do
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.90-96
    • /
    • 2012
  • The forced vibration response characteristics of a elastically restrained pipe conveying fluid with attached mass are investigated in this paper. Based on the Euler-Bernoulli beam theory, the equation of motion is derived by using Hamilton's principle. The effects of attached mass and spring constant on the forced vibration characteristics of pipe at conveying fluid are studied. The forced deflection response of pipe with attached mass due to the variation of fluid velocity is also presented. The deflection response is the mid-span deflection of the pipe. The dimensionless forcing frequency is the range from 0 to 16 which is the first natural frequency of the pipe.

Examination on Shock Vibration of Feed-Water Recirculation piping in Power Site (발전소 대형 수배관계의 충격성 이상 과도진동의 특성 고찰 사례)

  • Kim, Yeon-Whan;Yang, Gyeong-Hyeon;Bae, Si-Yeon;Yu, Jae-Myeong;Jo, Jong-Hyeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.475-479
    • /
    • 2011
  • Leak problem with large pressure drop occurrs non-periodic shock pulsation due to the deterioration of a isolation valve in feed-water recirculation piping system. This paper discusses on the shock vibration and noise occurred due to the effect of acoustical shock pulsations by degradation of the isolation valve in a power site.

  • PDF

Vibration Analysis of Discharge Pipe with Fluid Pulsation in a Rotary Compressor (유체 맥동을 고려한 압축기 토출 배관의 진동 응답 해석)

  • 서영수;정의봉
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1049-1054
    • /
    • 2002
  • Fluid Pulsation in pipe usually cause several forces and these forces make mechanical vibration and noise. Protecting pipe from mechanical vibration is very important problem because vibration make pipe damage and break. To analyze pipe, we must formulate both the fluid pulsation force and vibration of pipe. In this paper fluid force from pulsation is modeled by Fluid Dynamics and solved by FEM(finite element method). The discharge pipe is also modeled by the FEM with use of 6 dof beam model. The acceleration of discharge pipe is estimated by the suggested method in this paper. The comparision of estimated results with experimental results show good agreement, which verified the validation of this method

  • PDF

Vibration Analysis of Pipes Considering Fluid Pulsation (유체맥동을 고려한 배관계의 진동해석)

  • Seo, Young-Soo;Jeong, Seok-Hyeon;Lee, Seong-Hyeon;Hong, Chin-Suk;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1050-1056
    • /
    • 2006
  • In this paper, a new method for the stability analysis of a pipe conveying fluid which pulsates periodically is presented. The finite element model is formulated liking into consideration of the effects of the fluid pulsating in a pipe. The damping and stiffness matrices in the finite element equation vary with time due to pulsating fluid. Coupled effects of several harmonic components in the velocity of fluid to a pipe is discussed. A new unstable region appears which will not appear in the stability analysis of single pulsating frequency. A method to directly estimate the forced response of pipe is also discussed. The results presented in this paper are verified by the time domain analysis.

A Diagnosis and Solution Case of Structural Vibration caused by Pipe (배관에 의한 구조진동 진단 및 대책)

  • Lee, J.H.;Gu, D.S.;Choi, B.K.
    • Journal of Power System Engineering
    • /
    • v.12 no.2
    • /
    • pp.18-22
    • /
    • 2008
  • A few intake stations have vibration problems caused by pipes. The vibration transffered from pipes excites building severely. Therefore, the crack is generated on building wall and people who work at intake station are damaged. In this paper, the vibration is measured and analysis is carried out for pipes at intake station in order to identify the usefulness and effectiveness of the solution proposed for pipe resonance avoidance. According to the result of analysis, the vibration of pipes is reduced by bellows.

  • PDF

An Experimental Study on Vibration Control of Water Hammering in Water Pipe System (급수배관시스템의 수충격 진동제어를 위한 실험적 연구)

  • Lee, Jang-Hyun;Lee, Hyo-Haeng;Kwon, Byoung-Ha;Oh, Jin-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.453-458
    • /
    • 2008
  • Pump of high lift use to development of a technological level according as a building grow big. Water-Hammer to increase by valve of fast to closing agreeably to pipe laying to accept electronic valve, because by a damage of piping-system and the devil knows injury of vibration. Water-Hammer take a low effect to various method for solve. A New type manufacture develop and testing of pipe line to same to axis use to accumulator for water-Hammer to low effect and liner control of pressure. Impact-pressure of absorption ability and confirmation to decrease of vibration level through to preexistence manufactures and comparative test. Water-hammer and pipe vibration make low of piping system.

  • PDF

Vibraiton and Power Flow Analysis for the Branched Piping System by Wave Approach (파동접근법을 이용한 분기된 배관계의 진동 및 파워흐름해석)

  • Koo, Gyeong-Hoe;Park, Yun-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1225-1232
    • /
    • 1996
  • In this paper the vibration and power flow analysis for the branched piping system conveying fluid are performed by wave approach. The uniform straight pipe element conveying fluid is formulated using the dynamic stiffness matrix by wave approach. The branched piping system conveying fluid can be easily formulated with considering of simple assumptions of displacements at the junction and continuity conditions of the pipe internal flow. The dynamic stiffness matrix for each uniform straight pipe element can be assembled by using the global assembly technique using in conventional finite element method. The computational method proposed in this paper can easily calculate the forced responses and power flow of the branched piping system conveying fluid regardless of finite element size and modal properties.

Reduction of the Vibration Transmissibility for the Sea-Water Conveying Pipe in a Ship According to its Mount Shape (마운트 형상에 따른 선박용 해수 이송 배관의 진동 전달률 감소)

  • Han, Hyung-Suk;Jeong, Weui-Bong;Cha, Young-Ju
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.6
    • /
    • pp.688-694
    • /
    • 2008
  • The reduction of the structure-borne noise is very important in order to reduce the noise of a ship. The noise at the high frequency range usually comes from the fluid flowing. The noise from the sea-water conveying pipe is one of the main source on these high frequency range. Therefore, the transmissibility variations are evaluated according to the shape of the rubber mount. The evaluations are performed with the frequency response function numerically and experimentally.

Finite Element Analysis of 2ply Bellows Expansion Joint based on Cyclic Loading Test (2ply 벨로우즈 신축관이음의 반복하중 실험 기반 유한요소 해석)

  • Son, Ho-Young;Jeon, Bub-Gyu;Lee, Sang-Woo;Ju, Bu-Seog
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.311-312
    • /
    • 2022
  • 최근 발생한 경주 및 포항 지진으로 인해 다수의 매립배관 손상이 보고되었다. 벨로우즈 신축관이음은 기하학적 특성으로 인해 진동 및 침하 등으로 인한 손상을 저감시킬 수 있다. 벨로우즈 신축관이음관의 내진 성능평가에 대한 실험적 혹은 해석적 연구는 미미한 상황이다. 본 연구는 벨로우즈 신축이음관의 내진성능을 분석하기 위해 반복하중 기반의 실험적 연구를 수행하였다. 또한 실험결과를 기반으로 3차원 유한요소 모델을 구축하였으며 실험과 해석에서 얻어진 하중-변위 관계를 비교하였다. 해석 모델에서 전체적인 강성이 큰 것으로 나타났으며 최대 변위가 작용할 때 에너지 소산량은 약 10% 가량 큰 것으로 나타났다.

  • PDF