• 제목/요약/키워드: 방연

검색결과 61건 처리시간 0.037초

목조건축의 방연(方椽) 용례 연구 (A Study on the Use of Bangyeon on Wooden Architecture)

  • 조현정;김왕직
    • 건축역사연구
    • /
    • 제26권1호
    • /
    • pp.17-30
    • /
    • 2017
  • The aim of this study is to examine the square shape cases of rafter end header with special reference to wooden architecture and Uigwe records. In Uigwe, the member Bangyeon is widely used in multiple Changung and Chansil, and it is the most used in various gates in the buildings. It is also found in Haenggak and Subokbang. In the surviving wooden architecture, Bangyeon is found in pavilion, colonnade and gate in Changdeokgung Palace, and it is often seen in palace architecture. It is rare in private sector, and it is shown in Sangju Yangjindang and Andong Songsojongtaek. A total of 48 cases in Uigwe, can found records of Bangyeon. According to the records, mainly Yeonggeon Uigwe and Salleung Uigwe, it can be found that gates, also Bangyeon was used.

방연(方椽)이 표현된 승탑의 용례와 특징에 관한 연구 (A Study on the Use and Features of Bangyeon on the Seungtap)

  • 조현정;김왕직
    • 건축역사연구
    • /
    • 제26권2호
    • /
    • pp.7-14
    • /
    • 2017
  • Rafter is a member for roof and plays a role in protecting shaft members under rafter such as pillar, beam and girder from natural environment and to fix by supporting finished materials of roof. It is common in the Korean architecture that rafter cross-section is paired with circular form and Buyeon cross-section is paired with the square shape. However, while there are not many, some architectures have rafter end header in the square shape. The aim of this study is to examine the square shape cases of rafter end header with special reference to stone structure. As a result, among stone structure related to Bangyeon, the majority case is seen at Palgakwondang type Seungtap. It was shown in the Seungtap of monk of Gusanseonmun school in the later Unified Silla to the early Goryeo period that succeeded Seodang Jijang.

급기가압 제연시스템의 성능개선을 위한 무지향성 제연댐퍼시스템 개발연구 (Non-directional Smoke Damper System Development for Pressurized Smoke Control System)

  • 배상환;류형규;이병석;장세웅
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.357-360
    • /
    • 2012
  • 본 연구에서는 기존 급기가압 제연의 성능평가를 수행하였고, 이를 기반으로 급기가압제연댐퍼의 기류방향에 따른 방연풍속 확보가 곤란한 점에 착안하여 무지향성 제연댐퍼시스템을 개발하였다. 개발된 무지향성 제연댐퍼를 대상으로 Mockup 실험을 수행한 결과 화재실 출입문과 제연댐퍼의 설치위치와 상관없이 방연풍속 확보가 가능하여 급기가압제연시스템의 성능개선효과가 매우 큰 것으로 나타났다.

  • PDF

대형공간의 연기확산 방지를 위한 국내·외 방연구획 기준 분석에 관한 연구 -고양시 터미널 화재 사례 분석을 중심으로- (A Study on the Smoke Compartment Standards Analysis of Domestic and Abroad for Prevention of Smoke Spread in Large-Scale Buildings -Focused on the Analysis of Goyang Bus Terminal Fire Incident-)

  • 김혜원;한지우;이병흔;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.118-119
    • /
    • 2018
  • In this study, it analyses the problems of the Fire Compartment in Goyang Bus Terminal. Based on analysed data, it is confirmed the necessity of the Smoke Compartment installation for Protecting the Smoke Spread in Large-Scale Buildings using of FDS(Fire Dynamics Simulation). In addition it suggest that the necessity of Smoke Compartment application method and Development of Design Guideline.

  • PDF

화재시 연기확대 방지를 위한 건축물 구획공간에서의 방연성능 확보에 관한 조사 연구 (A Study on the Protection of Smoke Control Performance in Building Enclosure to Prevent the Expansion of Smoke in Fire)

  • 진승현;김혜원;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.91-92
    • /
    • 2019
  • In case of fire in a compartmentalized building area, a number of casualties are caused by smoke production. Accordingly, openings, penetrations and joints in compartmentalized spaces should be secured not only for fire resistance but also for smoke-proofing. However, domestic test regulations stipulate test methods for refractory performance of penetrations and joints, but do not specify separate deferral performance. In the case of openings, the test for the smoke performance exists at room temperature, but the smoke performance at high temperature is not secured, so countermeasures are needed.

  • PDF

건축물의 연기확산 방지 및 제어를 위한 방연구획의 법제화 제안 (Proposal of Legislation of Smoke Compartment for Prevention and Control of Smoke Diffusion in Buildings)

  • 권영진;진승현;김혜원
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.96-97
    • /
    • 2019
  • According to building law, there are only regulations on the fire prevention compartments that can perform the function of partial smoke compartment, but the building law management of the smoke compartment for effective smoke diffusion prevention and control is not possible. The lack of control on the smoke compartment such as leakage rate on the penetrating part, and the lack of leakage rate in the design of smoke control of fire safety law resulted in the absence of fundamental safety technology. Therefore, this study seeks to find solutions to domestic problems after reviewing relevant domestic laws and regulations.

  • PDF

번역 - 고층건물의 화재안전

  • 이승위
    • 방재와보험
    • /
    • 통권33호
    • /
    • pp.32-34
    • /
    • 1987
  • 본 기사는 남 아프리카 방화 협회에서 발간하는 "Fire Protection" 1985년 3월호에 게재된 J.S Strydom씨의 글을 본 협회 방재연구부 이승위 부장이 번역한 것이다. 저자는 방화.방연을 위한 조처가 점검상 가장 역점을 두어야 할 체크 항목이라고 역설하고 있다.

  • PDF