A Study on the Analysis of Ciliary Beat Frequency in Human Respiratory Tract n Vivo (레이저 산란 기법을 이용한 인체 기도 내 섬모 운동 신호의 분석에 관한 연구)

  • 이원진;이재서;이재서;이철희;권태영
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.339-344
    • /
    • 2000
  • The mucociliary system is one of the most important airway defense mechanisms in human body and impairment of ciliary movement results in various diseases in respiratory tract. In this study, we have developed a system that can measure ciliary movement in vivo and quantified ciliary beat frequency (CBF) through autoregressive (AR) power spectrum. To measure the frequency in vivo, we applied a photoelectric method that was composed of a laser light and a fiber optic probe. Scattered signals are transferred to a PC in which they are displayed on the monitor and its CBF is determined by the AR method in were acquired. For 8 normal subjects, the analyzed CBFs ranged from 5 to 10Hz and its mean was 7.3${\pm}$1.1Hz. This result showed similar aspects to the reported results of CBFs to data. We expect that this result will be applied in various clinical studies such as analysis of CBF changes by drugs or by diseaes.

  • PDF

Measurement and Analysis of X-ray Absorbed Dose in Water Phantom using TLD (TLD를 이용한 X-선 수중 흡수선량 측정 및 해석)

  • Oh, Jang-Jin;Jun, Jae-Shik;Hah, Suck-Ho;Kim, Wuon-Shik;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.21-28
    • /
    • 1988
  • Absorbed dose in water was analyzed by Burlin's general cavity theory for medium X-ray energy region (HVL : 0.29, 0.84, 1.60, 2.62mm Cu) using LiF : PTFE TL dosimeter(0.4 mm ${\times}\;{\phi}$ 12.5mm, hot-pressed LiF TLD-700) which was enclosed in lucite capsule. The absorbed dose rate at 5cm depth in water phantom was determined with measurement error of ${\pm}5%$. This result was compared to that of the ionization method, indirectly absolute measurement method, of which measurement error of ${\pm}2%$. The difference between these two results lies within measurement error of LiF : PTFE method. Therefore, the absorbed dose in water obtained by LiF: PTFE is reliable, and this result suggests the base to estimate dose-equivalent for medium X-rays.

  • PDF

Development of a test system for analysis of air bubble behavior (에어버블 거동 분석을 위한 실험장치 개발)

  • Lee, Hyo Sang;Chang, Hyung Joon;Lee, Ho Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.475-475
    • /
    • 2016
  • 생활의 편의를 위하여 인간은 여러 종류의 시설을 만들고 있으며, 이에 필요한 전기를 공급하기 위하여 여러 종류의 발전소를 건설 운영하고 있다. 특히, 원자력 발전은 2014년을 기준으로 전체 전력생산량의 약 30%를 담당하고 있으며, 늘어나는 전력 수요를 감당하기 위하여 다수의 원자력 발전소 건설계획을 수립하고 있다. 원자력 발전소는 발전과정에서 생성되는 고열을 냉각시키기 위하여 다량의 물을 필요로 하기 때문에 연안에 위치한다. 물을 안정적으로 취수하는 것은 원자력 발전소의 안정성 확보에 큰 영향을 미치는 요소이다. 하지만, 유류 등의 오염 물질 또는 해파리 등의 생물체에 의하여 취수구가 마비되어 냉각수를 공급하지 못하는 사고가 종종 발생하고 있다. 원자력 발전소가 발전 중단이 되면 하루 약 10억원의 경제적 손실이 발생할 수 있고, 동일본 대지진의 예에서 확인할 수 있는 바와 같이 2차 피해가 발생하여 엄청난 재앙을 초래할 수 있다. 취수구로 유입되는 유류 등의 오염물질과 생물체를 차단하기 위하여 물리적인 방법과 생물학적 방법을 이용한 여러 가지 장치 및 기법이 고안되고 있지만, 생물학적인 방법은 개체군과 종류의 변화로 그 적용이 곤란하여 물리학적인 방법을 이용한 연구가 주를 이루고 있다. 대표적인 물리학적 장치는 해파리 제거용 그물이 있으나, 포집되는 해파리의 지속적인 제거를 위한 비용적인 문제와, 잠수부의 안전 문제가 발생하고 있다. 이와 같은 문제를 해결하기 위해서 최근 가장 주목받고 있는 방법은 에어버블을 이용하여, 유해 물질과 생물체를 차단하는 방법이다. 에어버블은 수심조건에 영향을 받지 않고, 취수구가 설치된 영역으로 유해물질의 유입 자체를 방어할 수 있어 몇 몇 선진국에서는 실용화 단계에 접어들고 있다. 본 연구에서는 에어버블 거동을 특성을 파악하기 위해서는 에어버블의 상승속도, 특성, 압력 및 수심조건 등을 고려할 수 있는 실험 장치를 개발하는 것을 목적으로 하였다. 이를 위하여 선행연구결과 및 현장조건을 고려하여, 취급이 간단하고, 실험조건 조절이 용이한 원통형 실험 장치를 개발하였다.

  • PDF

A Study on the Interrelationship between DISC Personality Types and Cyber Security Threats : Focusing on the Spear Phishing Attacks (DISC 성격 유형과 사이버 보안 위협간의 상호 연관성에 관한 연구 : 스피어피싱 공격 사례를 중심으로)

  • Kim, Mookjung;Lee, Sangjin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.1
    • /
    • pp.215-223
    • /
    • 2019
  • The recent trend of cyber attack threat is mainly APT (Advanced Persistent Threat) attack. This attack is a combination of hacking techniques to try to steal important information assets of a corporation or individual, and social engineering hacking techniques aimed at human psychological factors. Spear phishing attacks, one of the most commonly used APT hacking techniques, are known to be easy to use and powerful hacking techniques, with more than 90% of the attacks being a key component of APT hacking attacks. The existing research for cyber security threat defense is mainly focused on the technical and policy aspects. However, in order to preemptively respond to intelligent hacking attacks, it is necessary to study different aspects from the viewpoint of social engineering. In this study, we analyze the correlation between human personality type (DISC) and cyber security threats, focusing on spear phishing attacks, and present countermeasures against security threats from a new perspective breaking existing frameworks.

Tracking of Yellowtail Seriola quinqueradiata Migration Using Pop-up Satellite Archival Tag (PSAT) and Oceanic Environments Data (위성전자표지와 해양환경자료를 이용한 방어(Seriola quinqueradiata) 이동경로 추적 연구)

  • Kim, Changsin;Yang, Jigwan;Kang, Sujin;Lee, Seung-Jong;Kang, Sukyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.5
    • /
    • pp.787-797
    • /
    • 2021
  • Yellowtail Seriola quinqueradiata tagged with a Pop-up Satellite Archival Tag (PSAT) was released off the coast of near the Moseulpo, Jeju Island and the ecological data during about 40 days was obtained. However, it is difficult to determine the spatial location of underwater ecological data. To improve the accuracy of estimating the Yellowtail migration route using temperature, suitable background field of the oceanic environment data was evaluated and used for input data. After developing of the tracking algorithm for migration route estimation, three experiment cases were estimated with ecological data among the surface layer, the mixed layer, and the whole water column. All tracking experiments move from western to eastern Jeju Island. Additionally, tracking experiment using 3D ocean numerical model reveal that it is possible to estimate the migration route using the fish ecological data of the entire water column. Therefore, using a large number of ecological data and a high-accuracy ocean numerical model to estimate the migration route seems to be a way to increase the accuracy of the tracking experiment. Moreover, the tracking algorithm of this study can be applied to small pelagic fishery using small archival electronic tags to track the migration route.

Protective Effects of Water dropwort and Jin-do turmeric on the Irradiation in Mouse (마우스에서 미나리와 진도 울금의 방사선조사에 대한 방어효과)

  • Yu, Ji-In;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.335-341
    • /
    • 2011
  • This paper searched the affect of Water dropwort and Tumeric on radiation exposure. By experimenting 50 male mouse, ICR type 5 weeks old male 25~30g, 5 mouse was divided in to each group respectively. A : 3 Gy control group, B : 5 Gy control group, C : 3 Gy, FW, D : 5 Gy FW, E : 3 Gy LW, F : 5 Gy LW, G : 3 Gy FT, H : 5 Gy FT, I : 3 Gy LT, J : 5 Gy LT FW : Ate Water dropwort before the radiation exposure. FT : Ate Tumeric before the radiation exposure. LW : Ate Water dropwort after the radiation exposure. LT : Ate Tumeric after the radiation exposure. During the 7 day radiation, Control group (A, B) received physiological saline (500mg/kg/day) in oral administration, LW and LT group (E, F, I, J) respectively received Water dropwort or tumeric (500mg/kg/day) in oral administration after the radiation, FW and FT group (C, D, G, H) respectively received Water dropwort or tumeric (500mg/kg/day) in oral administration before the radiation. As a result, an average leukocyte rate on 5 mouse was 200K/${\mu}L$ on group A. 6.46K/${\mu}L$ on group C which was in normal rate range (1.8-10.7 K/${\mu}L$). An average leukocyte rate was 23.33K/${\mu}L$ on group G. which was not normal rate, but compare to 200K/${\mu}L$, it was closer to normal rate. An average lymphocyte rate was 118.87K/${\mu}L$ on Group A. 1.51K/${\mu}L$ on Group G. which was in normal lymphocyte rate range (0.9-9.3K/${\mu}L$). An average thrombocyte rate was 4000K/${\mu}L$ on Group A. 1107 K/${\mu}L$ on Group C. 2759.6 K/${\mu}L$ on Group G. which was in normal thrombocyte rate range (592-2972 K/${\mu}L$). From this result, it was found that when exposed to radiation, Water dropwort and Tumeric have defensive effect in a preventive level. Also from an animal experiment, it was found that blood corpuscle rate returns to a normal rate. Based on this experiment, diverse research on this field should be conducted.

Effect Evaluation by Activity and Geometry Difference in Calibration on LSC (LSC 장비를 이용한 교정시 Activity 및 Geometry 차이에 의한 영향 평가)

  • Han, Sang-Jun;Lee, Kyung-Jin;Lee, Seung-Jin;Kim, Hee-Gang;Park, Eung-Seop
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.21-26
    • /
    • 2008
  • When the calibration on Liquid Scintillation Counter using the Solid $^3H$ Standard Source of 200,000DPM is executed, the uncertainty due to activity and geometry difference, exists. Therefore, this paper intends to evaluate environmental samples comparatively accurately as decreasing this uncertainty existing in the process of calibration. For this, measurements on samples manufactured by $^3H$ Standard Source and sensitivity study were performed. Also, this paper verified calibration results using Radioactivity-Error-Analysis Method, and evaluated quantitatively the effect by geometry and activity difference based on verification result. According to the result of sensitivity study, in case of using the exposure time of 75 sec and Repeat method, the measuring accuracy and precision of about $1{\sim}3%$ were increased in comparison with the existing method. By analysis result, the effect by activity difference did not appear, and a plastic cell existing into Teflon vial made a role as reflector. The less the effect of plastic cells are decreased, the more activity is high, and the effect of those can be neglected at the activity of 200,000 DPM.

Analysis of dose reduction of surrounding patients in Portable X-ray (Portable X-ray 검사 시 주변 환자 피폭선량 감소 방안 연구)

  • Choe, Deayeon;Ko, Seongjin;Kang, Sesik;Kim, Changsoo;Kim, Junghoon;Kim, Donghyun;Choe, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.113-120
    • /
    • 2013
  • Nowadays, the medical system towards patients changes into the medical services. As the human rights are improved and the capitalism is enlarged, the rights and needs of patients are gradually increasing. Also, based on this change, several systems in hospitals are revised according to the convenience and needs of patients. Thus, the cases of mobile portable among examinations are getting augmented. Because the number of mobile portable examinations in patient's room, intensive care unit, operating room and recovery room increases, neighboring patients are unnecessarily exposed to radiation so that the examination is legally regulated. Hospitals have to specify that "In case that the examination is taken out of the operating room, emergency room or intensive care units, the portable medical X-ray protective blocks should be set" in accordance with the standards of radiation protective facility in diagnostic radiological system. Some keep this regulation well, but mostly they do not keep. In this study, we shielded around the Collimator where the radiation is detected and then checked the change of dose regarding that of angles in portable tube and collimator before and after shielding. Moreover, we tried to figure out the effects of shielding on dose according to the distance change between patients' beds. As a result, the neighboring areas around the collimator are affected by the shielding. After shielding, the radiation is blocked 20% more than doing nothing. When doing the portable examination, the exposure doses are increased $0^{\circ}C$, $90^{\circ}C$ and $45^{\circ}C$ in order. At the time when the angle is set, the change of doses around the collimator decline after shielding. In addition, the exposure doses related to the distance of beds are less at 1m than 0.5m. In consideration of the shielding effects, putting the beds as far as possible is the best way to block the radiation, which is close to 100%. Next thing is shielding the collimator and its effect is about 20%, and it is more or less 10% by controlling the angles. When taking the portable examination, it is better to keep the patients and guardians far enough away to reduce the exposure doses. However, in case that the bed is fixed and the patient cannot move, it is suggested to shield around the collimator. Furthermore, $90^{\circ}C$ of collimator and tube is recommended. If it is not possible, the examination should be taken at $0^{\circ}C$ and $45^{\circ}C$ is better to be disallowed. The radiation-related workers should be aware of above results, and apply them to themselves in practice. Also, it is recommended to carry out researches and try hard to figure out the ways of reducing the exposure doses and shielding the radiation effectively.

The Responses of Antioxidative Enzymes and Salt Tolerance of Atriplex gmelini (Atriplex gmelini(가는갯능쟁이)의 내염성과 항산화 효소 반응)

  • 배정진;윤호성;추연식;송승달
    • The Korean Journal of Ecology
    • /
    • v.26 no.5
    • /
    • pp.273-280
    • /
    • 2003
  • Saline conditions invoke oxidative stress attributed to the overproduction of reactive oxygen species (ROS). Changes in quantum efficiency and antioxidative enzyme activity upon salt treatment were examined in a salt-tolerant plant, Atriplex gmelini, to test the hypothesis that salt tolerance of A. gmelini is due to the increased activity of antioxidative enzymes. A. gmelini showed optimum growth at 100 mM NaCl producing 116% of the shoot dry weight over control plants in 0 mM NaCl treatment. Healthy growth persisted up to 300 mM NaCl treatment maintaining normal internal water content and dry weight. No photochemical stress or damages on antioxidative defense system was obvious in plants of 2 and 4 day salt treatment which was indicated by increased quantum efficiency (Fv/Fm value), decreased stress index (Fo/Fm value), and increased activity of antioxidative enzymes such as SOD, APX, GR. However, the plants treated with 400 mM NaCl showed decrease in growth and in antioxidative enzyme activity although the enzyme activity was still higher than that of the 0 mM NaCl treated plants (l31%, 114%, and 134% of the SOD, APX, and GR activity, respectively). Interestingly, another important antioridative enzyme that scavenges H₂O₂ in plant cells, CAT, showed rapid decrease in its activity as salt concentration increased; 38%, 22%, 15% of the 0 mM NaCl treated plants at 200, 300, 400 mM NaCl treatments, respectively. It appears that the enzymes in ascorbate-glutathione cycle such as APX and GR play the major roles in scavenging ROS produced by salt stress in A. gmelini. After 6 days of salt treatment, the damage in photochemical and antioxidative defense system was indicated by decreased Fv/Fm value and increased Fo/Fm value. A. gmelini appears to cope with short term salt treatment by enhanced activity of the antioxidative defense system, whereas long term stress invoke oxidative stress by increased ROS due to the damages in photochemical and antioxidative system.

Development and Evaluation of Traffic Conflict Criteria at an intersection (교차로 교통상충기준 개발 및 평가에 관한 연구)

  • 하태준;박형규;박제진;박찬모
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.2
    • /
    • pp.105-115
    • /
    • 2002
  • For many rears, traffic accident statistics are the most direct measure of safety for a signalized intersection. However it takes more than 2 or 3 yearn to collect certain accident data for adequate sample sizes. And the accident data itself is unreliable because of the difference between accident data recorded and accident that is actually occurred. Therefore, it is rather difficult to evaluate safety for a intersection by using accident data. For these reasons, traffic conflict technique(TCT) was developed as a buick and accurate counter-measure of safety for a intersection. However, the collected conflict data is not always reliable because there is absence of clear criteria for conflict. This study developed objective and accurate conflict criteria, which is shown below based on traffic engineering theory. Frist, the rear-end conflict is regarded, when the following vehicle takes evasive maneuver against the first vehicle within a certain distance, according to car-following theory. Second, lane-change conflict is regarded when the following vehicle takes evasive maneuver against first vehicle which is changing its lane within the minimum stopping distance of the following vehicle. Third, cross and opposing-left turn conflicts are regarded when the vehicle which receives green sign takes evasive maneuver against the vehicle which lost its right-of-way crossing a intersection. As a result of correlation analysis between conflict and accident, it is verified that the suggested conflict criteria in this study ave applicable. And it is proven that estimating safety evaluation for a intersection with conflict data is possible, according to the regression analysis preformed between accident and conflict, EPDO accident and conflict. Adopting the conflict criteria suggested in this study would be both quick and accurate method for diagnosing safety and operational deficiencies and for evaluation improvements at intersections. Further research is required to refine the suggested conflict criteria to extend its application. In addition, it is necessary to develope other types of conflict criteria, not included in this study, in later study.