• Title/Summary/Keyword: 방사선계측

Search Result 711, Processing Time 0.028 seconds

Submentovertex cephalometrics in korean adults (한국 성인에서 이하 두정 방사선 계측사진 분석)

  • Nahm, Dong-Seok;Suhr, Chung-Hoon;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.1-7
    • /
    • 2000
  • It is important that the orthodontist accurately assess the degree to which facial asymmetry contributes to a given malocclusion before treatment planning. P-A, submentovertex and verticosubmental view have been used in the assessment of facial asymmetry. Among them, submentovertex view is rarely used because it has low reproducibility and is short of normal data and proper analysis method. The purpose of this study was to develop a submentovertex cephalomentrics and obtain normal data in Korean adults. The subjects consisted of 40 normal adults (male : 22, female 18) without the experience of orthodontic treatment. We find the 2 angular and 9 linear measurements. Though submentovertex cephalomentrics has the limitation in comparing the absolute length between right and left, it is useful to examine the relationship of skeletal and dental midline, the shape and location of condyle head and the shape of mandibular body in submentovertex view Therefore, if we understand the limitation of submentovertex cephalomentrics and use lateral , P-A and submentovertex cephalomentrics together, we will measure the location and amount of skeletal disharmony more exactly.

  • PDF

Development of a Techniques of the Performance Test for a Radiation Protection Devices and it's International Standards (방사선 방호용 계측기 성능평가 기술 개발 및 국제 표준)

  • Choi, Kil-Oung;Won, Sung-Ho;Kim, Jung-Ho;Hah, Suck-Ho;Yi, Chul-Young;Kim, Hyun-Moon;Lee, Min-Kee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • International Standardization in all technical area is gaining its momentum as its impact and implication over global trade is directly linked. The worldwide competition to secure a dominant position in the standardization process is ever growing over the years. In 2005, the International Technical Committee on Nuclear Instrumentation, which is a subunit of International Electro-technical Commission (IEC), was held in Korea under the auspices of MOST (Ministry of Science and Technology). Korea has adopted its Rule and Regulation as the National Standard. As a part of a link to National Mid-and Long-term Atomic Energy R&D Program of MOST, the technical development of a performance test for the radiation monitors was carried out under mechanical environment and electromagnetic immunity conditions. The characteristics of the radiation fields were also evaluated under the conditions and introduced to a techniques of performance test for the radiation protection instrumentation adopted IEC61526 standards and it's results was analyzed. We would like to share the experience gained in these efforts, failure as well as success, and to discuss the problems encountered and serious consideration to be taken into account in the future endeavor.

Comparison of landmark positions between Cone-Beam Computed Tomogram (CBCT) and Adjusted 2D lateral cephalogram (Cone-Beam Computed Tomogram (CBCT)과 Adjusted 2D lateral cephalogram의 계측점 차이에 관한 비교 연구)

  • Son, Soo-Jung;Chun, Youn-Sic;Kim, Minji
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.222-232
    • /
    • 2014
  • Purpose: This study aims to investigate if 2D analysis method is applicable to analysis of CBCT by comparing measuring points of CBCT with those of Adjusted 2D Lateral Cephalogram (Adj-Ceph) with magnification adjusted to 100% and finding out at which landmarks the difference in position appear. Materials and methods: CBCT data and Adj-Ceph (100% magnification) data from 50 adult patients have been extracted as research objects, and the horizontal (Y axis) and vertical (Z axis) coordinates of landmarks were compared. Landmarks have been categorized into 4 groups by the position and whether they are bilaterally overlapped. Paired t-test was used to compare differences between Adj-Ceph and CBCT. Results: Significant difference was found at 11 landmarks including Group B (S, Ar, Ba, PNS), Group C (Po, Or, Hinge axis, Go) and Group D (U1RP, U6CP, L6CP) in the horizontal (Y) axis while all the landmarks in vertical (Z) axis showed significant difference (P<.05). As a result of landmark difference analysis, a meaningful difference with more than 1 mm at 13 landmarks were indentifed in the horizontal axis. In the vertical axis, significant difference over 1 mm was detected from every landmark except Sella. Conclusion: Using the conventional lateral cephalometric measurements on CBCT is insufficient. A new 3D analysis or a modified 2D analysis adjusted on 19 landmarks of the vertical axis and 13 of the horizontal axis are needed when implementing CBCT diagnosis.

Digital imaging of film-based cephalograms using a digital camera (디지털 카메라를 이용한 필름 두부방사선사진의 디지털 이미지 전환)

  • Wang, Sung-Jin;Kim, Kyung-Ho;Choy, Kwang-Chul
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.448-457
    • /
    • 2004
  • As computer Programs for cephalometric analysis were developed in diagnosis & treatment planning, digital imaging of film-based cephalograms came to be needed. When a digital camera is used, a problem encountered the image distortion produced according to the focal length, which causes errors in indentifying landmarks. In addition, changes in the image size and compression ratio will inevitably produce a low quality image, causing errors in identifying landmarks. Hence. we have found the focal length producing the least image distortion when digital imaging the film-based cephalograms and the minimal digital camera setting which helps to identify the correct landmarks using the COOLPIX4500 digital camera (Nikon, Japan). The results were as follows The image distortion was minimized at a focal length of 16.4mm (79.4mm when converted into a 35mm film camera) when digital imaging the film-based cephalograms. When wide imaging, with a focal length of under IS.4mm, barrel distortion was found and when tole imaging. with a focal length of over 15.4mm pincushion distortion was found. The minimal digital camera setting was $2272{\times}1704$ pixel at normal (1/8) compression from which we can identify the correct landmarks at the same level as tracing the film-based cephalograms manually. As a result. when digital imaging the film-based cephalograms, using a COOLPIX4500 digital camera (Nikon, Japan), the focal length should be 16.4mm the pixel image size over $2272{\times}1704$, and the compression ratio over normal (1/8).

Evaluate the usefulness of Coincidence Summing Correction Factors for Cylinder and Extended Source Penelope Simulation (실린더 및 확장 소스 PENELOPE 시뮬레이션에 대한 동시합성보정 계수 유용성 평가)

  • Jang, Eun-Sung;Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.821-831
    • /
    • 2021
  • In order to calibrate energy and efficiency using the PENELOPE Code, a PENELOPE simulation was performed using a volume source. Here, we want to verify peak efficiency and usefulness by performing simultaneous measurement and correction. calculate the coincident sum correction for all volumes, first subdivide the volumes of the cylinder and the four Marinelli beakers into three heights again. Therefore, the simultaneous measurement correction coefficient in three areas and the simultaneous measurement correction coefficient for the entire volume source are calculated as output. At low energies, the j value for each source volume (50-300 ml) is small and increases significantly in the high energy range. Simulation results showed good agreement within 2.5% for all source volumes except for 50 ml and 300 ml, which were up to 4%. This means that the correction for the simultaneous measurement effect during measurement is effective. In addition. Based on this, it can be confirmed that there is an advantage to improve the detection efficiency when measuring various sources and environmental samples.

A Study on Electronic Circuit for Liwe-Time Correction in Multi-Channel Analyzer : Survey and Analysis (방사선 스펙트럼 계측기 (Multi-Channel Analyzer)의 Live-Time 보상회로에 관한 연구)

  • Hwang, I.K.;Kwon, K.H.;Song, S.J.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.784-791
    • /
    • 1995
  • This paper describes the counting-loss problem for radiation measurement Multi-channel analyzers and spectrometers adopt various techniques for compensation for counting-losses in process-ing the radiation pulses from a detector. Researchers hate tried to seek the best solution for the problem. However, any absolute solution has not been reached and vendors of radiation instruments use their own algorithms individually. This survey explains the various compensation algorithms with electronic implementation approach. Shortcomings and merits of each algorithm are also reviewed and a direction is suggested of the recommendable development strategy for counting-loss compensation.

  • PDF

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출-)

  • Lee, Geun-Ho;Lee, Sang-Han;Jang, Hyon-Joong;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.214-220
    • /
    • 2001
  • The clinical application of the three-dimensional radiographic technique had been limited to standard Broadbent-Bolton cephalometer with biplanar stereoradiography. We developed a new method for compensating the error of head position in ordinary non-biplanar cephalostat. It became to possible to use the three dimensional cephalogram commonly in clinical bases. 1. The method of methemetical compensation of head positioning error in non-biplanar condition was evaluated with dry skull. The error of the method of first and the second trial was $0.46{\pm}1.21$, $0.33{\pm}0.90mm$, which means the error of the head positioning correction in conventional cephalogram was within clinical acceptance. 2. The reproducibility of this system for clinical application was 0.54 mm ($-2.99{\sim}2.26mm$) which defines the absolute mean difference of the first and second trial. Compare to the The landmark identification error $1.2{\pm}1.6mm$, the error of the measurement was within the range of landmark identification error. The result indicates the adequate clinical accuracy of the computation of three-dimensional coordinates by compensation of the error of the head position in ordinary non-biplanar cephalostat.

  • PDF