Abstract
As computer Programs for cephalometric analysis were developed in diagnosis & treatment planning, digital imaging of film-based cephalograms came to be needed. When a digital camera is used, a problem encountered the image distortion produced according to the focal length, which causes errors in indentifying landmarks. In addition, changes in the image size and compression ratio will inevitably produce a low quality image, causing errors in identifying landmarks. Hence. we have found the focal length producing the least image distortion when digital imaging the film-based cephalograms and the minimal digital camera setting which helps to identify the correct landmarks using the COOLPIX4500 digital camera (Nikon, Japan). The results were as follows The image distortion was minimized at a focal length of 16.4mm (79.4mm when converted into a 35mm film camera) when digital imaging the film-based cephalograms. When wide imaging, with a focal length of under IS.4mm, barrel distortion was found and when tole imaging. with a focal length of over 15.4mm pincushion distortion was found. The minimal digital camera setting was $2272{\times}1704$ pixel at normal (1/8) compression from which we can identify the correct landmarks at the same level as tracing the film-based cephalograms manually. As a result. when digital imaging the film-based cephalograms, using a COOLPIX4500 digital camera (Nikon, Japan), the focal length should be 16.4mm the pixel image size over $2272{\times}1704$, and the compression ratio over normal (1/8).
Keywords
Digital camera; Film-based cephalogram; Digital imaging; Error of landmark identification;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Schulhof RJ, Computer evaluation : management. J Clin Orthod 1990;24:237-245   PUBMED
2 양원식. 치과교정진단학, 지성출판사. 1995;261-2
3 Liu JK, Chen YT, Cheng KS. Accuracy of computerized automatic identification of cephalometric landmark. Am J Orthod Dentofacial Orthop 2000;118:535-40   DOI   ScienceOn
4 Forsyth DB, Davis DN. Assessment of an automated cephalometric analysis system. Europ J Orthod 1996;18:471-8   DOI
5 Forsyth DB, Shaw WC, Richmond S, Roberts CT. Digital imaging of cep-halometric radiographs, part ll:image quality. Angle Orthod 1996;66:43-50   PUBMED
6 Rickettes RM. The evaluation of diagnosis to computerized cephalo-metrics. Am J Orthod 1969;55:795-803   DOI   ScienceOn
7 CheryI LH, Donald JF, Martin WG. Cephalometric digitization:A det ermination of the minimum scanner settings necessary for precise landmark identification. Am J Orthod Dentofacial Orthop 2001;119:472-81   DOI   ScienceOn
8 Dawood R. Digital radiology:A realistic prospect? Clin Radiol 1990;42:6-11   DOI   PUBMED   ScienceOn
9 Eppley BL. Computerized digital enhancement in craniofacial cephalo-metric radiography. J Oral Maxillofac Surg 1991;49:1038-43   DOI   ScienceOn
10 Kiliant DM. Cephalometric spreadsheets. J Clin Orthod 1985;19:448-55
11 Buschang PL, Ceen RF, Schroeder JN. Holographic storage of dental casts. J Clin Orthod 1990;24:308-11
12 이양구, 양원식, 장영일. 일반두부방사선계측사진과 디지털방사선계츨사진의 계 측점 식별의 오차 및 재현성에 관한 비교 연구. 대치교정지 2002;32:79-89
13 Forsyth DB, Shaw WC, Richmond S, Roberts CT. Digital imaging of cephalometric radiographs, part I:advantages and limitations of digital imaging. Angle Orthod 1996;66:37-42   PUBMED