• Title/Summary/Keyword: 바늘길이

Search Result 32, Processing Time 0.033 seconds

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.

Dielectric Characteristics of Gaseous $SF_6$ for Impulse Voltages in Presence of a Metallic Particle in GIS (가스절연개폐장치에 있어서 금속입자 존재시 임펄스전압에 대한 $SF_6$가스의 절연특성)

  • 이복희;이경옥;이창준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • This paper deals with the dielectric characteristics of $SF_6$ gas gap stressed by $\pm$1.2/44[$mutextrm{s}$] non-oscillating impulse and $\pm$0.4[$mutextrm{s}$]/1.14[MHz] oscillating impulse voltages in the presence of a needle-shape metallic particle in gas-insulated switchgear(GIS). Breakdown voltage-time (V-t) and breakdown voltage-gas pressure (V-p) characteristics were investigated and discussed. The experiments were carried out under highly inhomogeneous field geometry with a needle protrusion whose length and radius are 10[mm] and 0.5[mm], respectively. The gas pressure ranges from 0.1 to 0.5[㎫]. As a result, it was found that the electrical breakdown for both the positive and negative polarity develops with steplike pulses in leader mechanism, When subjected to the positive oscillating impulse voltage, the minimum breakdown voltages appeared in all the gas pressure ranges and the V-t curves have a pronounced upturning at short times to breakdown and give a little dependence of the gas pressure. On the other hand, in the case of the negative polarity the dependence of the V-t and V-p characteristics on the wave shape of the applied voltages is known to be appreciable.

  • PDF

Needle Decompression for Trauma Patients: Chest Wall Thickness and Size of the Needle (외상 환자에 대한 바늘감압술에서 흉벽 두께와 바늘 길이의 관계)

  • Kim, Jee-Wan;Jeong, Jin-Woo;Cho, Suck-Ju;Yeom, Seok-Ran;Han, Sang-Kyoon;Park, Sung-Wook
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.63-67
    • /
    • 2010
  • Purpose: A tension pneumothorax is a fatal condition that requires immediate intervention. Although a definitive treatment for a tension pneumothorax is a tube thoracostomy, needle decompression can provide temporary relief, that is lifesaving. The traditional procedure for needle decompression involves inserting a needle or catheter at the second intercostal space, the midclavicular line. Recent evidence suggests that the commonly used catheters do not have sufficiently penetrate the chest wall. There are also claims that a lateral approach to needle decompression is easier and safer than the traditional anterior approach. The purpose of this study is to evaluate the optimal approach for needle decompression for the Korean population by measuring chest wall thicknesses at the points used for both the anterior and the lateral approaches. Methods: The chest wall thickness (CWT) of trauma victims who visited the Emergency Center of Pusan National University Hospital was measured by computed tomography (CT) images. The CWT was measured at the points used for the anterior and the lateral methods and was compared with the length of commonly used catheters, which is 45 mm. Results: The mean CWT at the second intercostal space, the midclavicular line, was shorter than the CWT at the 5th intercostal space, the anterior axillary line. However, the percentage of patients whose CWT was greater than 45 mm was larger when measured anteriorly (8.2%) that when measure laterally (5.7%). Female patients and those older than 60 were more likely to have an anterior CWT greater than 45 mm (28.2% for females and 15.5% for those older than 60). Conclusion: The percentage of trauma victims in Korea whose CWT is greater than 45 mm is lower than the values previously reported by other countries. However, females and older patients tend to have thicker chest walls, so the lateral approach would be suggested when performing needle decompression for such patients with suspected tension pneumothoraces.

Three Dimensional Ultrasonographic Evaluation with Intra-articular Saline Injection in Rotator Cuff Tear (회전근 개 파열의 수술 전 3차원 초음파 검사에서 관절내 생리식염수 주사 후 검사의 정확도)

  • Yum, Jae-Kwang;Shin, Yong-Woon;Park, Shin-Seung
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.62-67
    • /
    • 2009
  • Purpose: The purpose of this study is to find out the accuracy and usability of the three dimensional ultrasonography in measuring the size of the rotator cuff tear, especially before and after the injection of normal saline into the glenohumeral joint. Materials and Methods: 14 patients of rotator cuff tear who were diagnosed and operated from August 2007 to September 2008 were included in this study and authors compared the size of rotator cuff tear measured with three dimensional ultrasonography with the real size measured intraoperatively. In preoperative ultrasonographic evaluation, horizontal and longitudinal length of rotator cuff tear before and after injection of normal saline intraarticularly. During the arthroscopic operation the size of tear was measured by passing a Kirschner wire through a spinal needle and direct measure was performed in open surgery. Results: The average difference was 8 mm in horizontal and 1.9 mm in longitudinal length of tear without saline injection between ultrasonographic and intraoperative measure. The average difference was 4.1 mm in horizontal and 1.6 mm in longitudinal length of tear after the normal saline injection. Conclusion: In three dimensional ultrasonographic evaluation in rotator cuff tear, intraarticular normal saline injection would produce more accurate results.

  • PDF

A Study on the Processing of Long Fiber-Reinforced Composite Materials for Thermoforming On the Correlation Coefficient between Separation and Orientation (Thermoforming용 長纖維强化 複合材料의 成形工程에 관한 硏究 分離$\cdot$配向의 相關계수)

  • 이동기;김정락;김상필;이우일;김이곤
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1106-1114
    • /
    • 1993
  • A composite material is composed of a reinforcement and a matrix, which determine mechanical characteristics of the molded part. There is no doubt that the properties of a composite material depend not only on the characteristics of the matrix but also on the structure of glass fiber mat and a fiber type of reinforcement. Therefore it is very important to study the composites of reinforcement and the matrix, and to control the fiber type in the process of molding of composite materials. In this study, the specimen was made of a glass fiber mat of 6-7mm thickness by scattering it in the air after cutting the glass fiber mat with needle punching makes change according to the type of needle and the number of times of stretching. First the sheet was made by means of a hot-press after accumulating a matrix and a glass fiber according to each mat structure of glass fiber. It was heated the manufactured sheet with the dry oven and molded it a secondary high temperature compression by a 30 ton oilhydraulic press. A definition of a correlation coefficient is showed up during this period and find it out with the relation of the fiber-matrix separation and the fiber orientation. We studied effects of the glass fiber mat structures on the correlation coefficient.

Laser Induced Microjet Drug Delivery System: Drug Permeation Depending on Laser Wavelength and Pulse Duration (레이저 유도 마이크로젯을 활용한 약물 전달 방식: 레이저 파장 및 펄스길이에 따른 약물 침투 분석)

  • Jang, Hun jae;Ham, Hwi chan;Yoh, Jai ick
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.7
    • /
    • pp.463-468
    • /
    • 2017
  • For transdermal drug delivery, needless injection system is composed of laser and microjet injector. Main mechanism of microjet injector is the laser-induced bubble. Nd:YAG and Er:YAG laser are used as a power source. Laser parameters such as pulse duration and wavelength are considered, which are core parameters to control the bubble motion. The Nd:YAG laser, pulse duration is short than bubble life time making cavitation like bubble while in Er:YAG laser, long pulse duration and high absorption in water drive bubble as a boiling bubble. Detailed motion of bubble and microjet is captured by the high speed camera. So it is observed that microjet characteristics are determined by the bubble behavior. The performance of drug delivery system is evaluated by fluorescent staining of guinea pig skin.

Estimating Surface Orientation Using Statistical Model From Texture Gradient in Monocular Vision (단안의 무늬 그래디언트로 부터 통계학적 모델을 이용한 면 방향 추정)

  • Chung, Sung-Chil;Choi, Yeon-Sung;Choi, Jong-Soo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.7
    • /
    • pp.157-165
    • /
    • 1989
  • To recover three dimensional information in Shape from Texture, the distorting effects of projection must be distinguished from properties of the texture on which the distortion acts. In this paper, we show an approximated maximum likelihood estimation method in which we find surface orientation of the visible surface (hemisphere) in gaussian sphere using local analysis of the texture. In addition, assuming that an orthogonal projection and a circle is an image formation system and a texel (texture element) respectively, we drive the surface orientation from the distribution of variation by means of orthogonal projection of a tangent direction which exists regularly in the arc length of a circle. We present the orientation parameters of textured surface with slant and tilt in gradient space, and also the surface normal of the resulted surface orientationas as needle map. This algorithm is applied to geographic contour (artificially generated chejudo) and synthetic texture.

  • PDF

Study of the Length of Needle Thoracostomy Catheter Needed for Patients with Chest Trauma (흉부 외상 환자에서 늑막 천자를 위해 바늘 도관의 길이에 대한 연구)

  • Kang, Sung Won;Ryoo, Hyun Wook;Park, Jung Bae;Seo, Kang Suk;Chung, Jae Myung
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.1-4
    • /
    • 2009
  • Purpose: This study was conducted to evaluate the length of the catheter used in a needle thoracostomy for emergency decompression of a tension pneumothorax by measuring the chest wall thickness (CWT) in patients with chest trauma Methods: A retrospective review of 201 patients with chest trauma who had been transported the emergency department in a tertiary university hospital in a metropolitan area between 1 January and 31 February 2007 was performed. The average CWT at the second intercostal space (ICS) in the midclavicular line (MCL) was measured by using a chest computed tomography scan. Results: As the left and the right mean CWTs were $3.4{\pm}1.0cm$ and $3.4{\pm}1.0cm$, respectively, there was no significant statistical difference between them. The mean CWT of female patients was significantly higher than that of male patients (p=0.001). The mean CWT of patients under the age of 65 years was significantly thicker than that of the patients over the age of 65 years (p<0.001). Of the studied patients, 12 (6.0%) a CWT > 5 cm. Conclusion: A 5 cm-length catheter in a needle thoracostomy may be insufficient for emergency decompression of a tension pneumothorax, so a catheter longer than 5 cm in length is needed.

Prediction of Optimal Gluteal Intramuscular Needle Length by Skinfold Thickness Measurements in Korean Adults (피부주름두께 측정을 통한 성인의 둔부 근육주사 바늘의 최적 길이 예측)

  • Choi, Dong-Won;Sohng, Kyeong-Yae;Kim, Bum-Soo
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.6
    • /
    • pp.844-851
    • /
    • 2010
  • Purpose: This study was conducted to assess optimal needle length for gluteal intramuscular injections (IM) via simple skinfold thickness (SFT). Methods: For this study, 190 healthy adults were recruited and grouped into eight groups according to gender and body mass index (BMI) (kg/$m^2$). The Korean Society for the Study of Obesity criteria defines a BMI under 20 as underweight, 20.1-22.9 as normal, 23-24.9 as overweight and over 25 as obese. For each participant, the SFT of dorsoguteal (DG) and ventrogluteal (VG) sites were measured using a caliper. Subcutaneous tissue thickness was acquired through ultrasonic images. Results: For men in the overweight and obese groups at the DG site, for the obese group at the VG site, and for women in the normal weight, overweight and obese groups at both sites, the mean subcutaneous tissue thickness exceeded 1.84 cm, the minimal length for a 1 inch needle used for IM. At the DG site, optimal intramuscular needle length (OINL) was 1.4 times in women and 1.0 times in men compared to SFT. At the VG site, OINL was 1.3 times in women and 0.9 times in men compared to SFT. Conclusion: The results of this study suggest that SFT is a reliable index to determine optimal needle length with minimal effort prior to IM.

Recent Research Trend in Microneedle Fabrication Using 3D Printing (3D 프린팅을 이용한 마이크로니들 제작의 최신 연구 동향)

  • Choo, Sangmin;Jung, Jae Hwan
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.379-384
    • /
    • 2021
  • A microneedle is a tool that used for drug delivery and diagnosis. Unlike general injections, the microneedle is short in length, enabling effective drug delivery while minimizing pain and risk of infection. Conventionally, microneedles have been manufactured precisely at a nanometer level based on microelectro mechanical systems (MEMS) technology, requiring expensive equipments & maintenance and complicated processes. To address the issues, 3D printing research has been conducted to fabricate microneedles simply, economically, and rapidly. Since 3D printing facilitates to manufacture prototypes and apply feedbacks, it is advantageous for the development and commercialization of microneedle for pharmaceuticals and cosmetics. Therefore, this review will introduce stereolithography (SLA), two-photon polymerization (2PP), dynamic light processing (DLP), continuous liquid interface production (CLIP), and fused deposition modeling (FDM) 3D printing technologies and also highlight research trends for microneedle production using them. Furthermore, the limitation of the current microneedle technology and the direction to be solved in the future will be discussed.