• Title/Summary/Keyword: 미세결합

Search Result 717, Processing Time 0.035 seconds

EFFECT OF INCREASING APPLICATION TIME OF SINGLE BOTTLE ADHESIVES TO MICROTENSILE BOND STRENGTH OF DRIED DENTIN (수종의 단일병 접착제의 적용 시간 연장이 건조 상아질의 미세인장 결합강도에 미치는 영향)

  • Kim, Hak-Geun;Kim, Dong-Jun;Hwang, Yun-Chan;Oh, Won-mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.435-441
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of increasing application time of single bottle adhesives (SBA) to microtensile bond strength (MTBS) of dried dentin. To expose the superficial dentin surfaces, human molars were sectioned perpendicular to the long axis of tooth. $32\%$ phosphoric acid gels were applied for 15s and rinsed. The teeth were randomly assigned to 3 groups ; S group (Single Bond), O group (One-Step), P group (Prime & Bond NT). Each group was divided to 3 subgroups (W: dentin wipe with wet gauge and light cured immediately, D, dentin dried for 30s and light cured immediately, 30: dentin dried for 30s and light cured after applying SBA for 30s). Composite resin was built up on the dentin surface and sectioned to obtain 20 specimens with $1mm^2$ cross sectional area and the MTBS was measured. For Single Bond, the mean MTBS of S-W and S-30 group were higher than that of S-D group statistically (P<0.05). For One-Step, the mean MTBS of O-D group was statistically lower than that of O-W group (P<0.05). For Prime & Bond NT, the mean MTBS of P-30 group was statistically lower than that of P-D group (P<0.05).

Effect of 2% chlorhexidine application on microtensile bond strength of resin composite to dentin using one-step self-etch adhesives (2% 클로르헥시딘 적용이 한 단계 자가부식 접착제를 이용한 복합 레진의 상아질에 대한 미세인장 결합강도에 미치는 효과)

  • Jang, Soon-Ham;Hur, Bock;Kim, Hyeon-Cheol;Kwon, Yong-Hun;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.486-491
    • /
    • 2010
  • Objectives: This study examined the effect of 2% chlorhexidine on the ${\mu}TBS$ of a direct composite restoration using one-step self-etch adhesives on human dentin. Materials and Methods: Twenty-four extracted permanent molars were used. The teeth were assigned randomly to six groups (n = 10), according to the adhesive system and application of chlorhexidine. With or without the application of chlorhexidine, each adhesive system was applied to the dentin surface. After the bonding procedure, light-cure composite resin buildups were produced. The restored teeth were stored in distilled water at room temperature for 24 hours, and then cut and glued to the jig of the microtensile testing machine. A tensile load was applied until the specimen failed. The failure mode was examined using an operating microscope. The data was analyzed statistically using one-way ANOVA, Student's t-test (p < 0.05) and Scheffet's test. Results: Regardless of the application of chlorhexidine, the Clearfil $S^3$ Bond showed the highest ${\mu}TBS$, followed by G-Bond and Xeno V. Adhesive failure was the main failure mode of the dentin bonding agents tested with some samples showing cohesive failure. Conclusions: The application of 2% chlorhexidine did not affect the ${\mu}TBS$ of the resin composite to the dentin using a one-step self-etch adhesive.

Evaluation of Microtensile Bond Strength of Sealant Depending on the Duration of Etching and the Use of Bonding Agent (치면열구전색제의 산부식 시간과 접착제 유무에 따른 미세인장결합강도 평가)

  • Shim, Seoyoun;Song, Hojun;Yang, Sunmi;Kim, Jaehwan;Kim, Seonmi;Choi, Namki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.3
    • /
    • pp.299-306
    • /
    • 2018
  • The aim of this study was to evaluate the effect of etching time and bonding agents on bond strength of sealant applied to the occlusal surface of primary molars. Forty non-carious exfoliated human primary molars were included in the study. The teeth were randomly divided into 4 groups for measurement. For group I, no acid etching treatment was used. For group II, III, and IV, acid etching gels were applied on the occlusal surface for 15, 30, and 60 seconds, respectively. Each group was divided into 2 subgroups; one group was treated with bonding agents on the enamel while the other was not. Microtensile bond strength was evaluated using a universal testing machine. There were no statistically significant differences in bond strength with varying duration of etching among groups. The results revealed that the use of bonding agents prior to application of fissure sealant increased the bond strength(p < 0.05). It could be concluded that etching time greater than 15 seconds does not significantly enhance the bond strength, but the use of bonding agents as an intermediate layer between the primary molar and fissure sealant would be beneficial in increasing the bond strength.

MICROLEAKAGE OF 7TH GENERATION BONDING SYSTEM (7세대 결합제의 미세누출에 관한 연구)

  • Lee, Sang-Yup;Kim, Dae-Eup;Ra, Ji-Young;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.422-428
    • /
    • 2006
  • Dentin bonding system have recently been developed in an effort to simplify and shorten bonding procedure. The intent of this study was to evaluate microleakage of newer generation of dentin bonding system comparing with other generations. Forty extracted human premolar teeth were randomly assigned to four groups for bonding : the 4th generation bonding system (Scotchbond Multi-Purpose). the 5th generation bonding system (Clearfil SE Bond), 6th generation bonding system (AQ bond) and 7th generation bonding $system(i-bond)^{TM}$ Class V cavities were prepared in buccal and lingual surface. The cavities were restored with composite resin (Z100) after the application of dentin bonding systems according to the instructions of the manufacturer Samples were thermocycled and immersed in methylene blue dye(2%). Each sample was sectioned with Isomet and evaluated for microleakage using stereomicroscopy. The mean value of the microleakage in 7th generation bonding system was greater than those of 4, 5, 6th generation dentin bonding system. Statistically, the mean values of microleakage between 4th and 7th generation bonding system were significantly different from each other (p<0.05).

  • PDF

Interaction of CLIP-170, a Regulator of Microtubule Plus End Dynamics, with Kinesin 1 via KIF5s (미세소관의 plus end dynamics를 조절하는 CLIP-170과 kinesin 1의 KIF5s를 통한 결합)

  • Jang, Won Hee;Jeong, Young Joo;Lee, Won Hee;Kim, Mooseong;Kim, Sang-Jin;Urm, Sang-Hwa;Seog, Dae-Hyun
    • Journal of Life Science
    • /
    • v.27 no.6
    • /
    • pp.673-679
    • /
    • 2017
  • Microtubules are long rods in the cytoplasm of cells that plays a role in cell motility and intracellular transport. Microtubule-based transport by motor proteins is essential in intracellular transport. Kinesin 1 is a molecular motor protein that mediates the intracellular transport of various membranous vesicles, mRNAs, and proteins along microtubules. It is comprised of two heavy chains (KHCs, also called KIF5s) and two light chains (KLCs). KIF5s bear a motor domain in their amino (N)-terminal regions and interact with various cargoes through the cargo-binding domain in their carboxyl (C)-terminal regions. To identify proteins interacting with KIF5B, yeast two-hybrid screening was performed, and a specific interaction with the cytoplasmic linker protein 170 (CLIP-170), a plus end microtubule-binding protein, was found. The coiled-coil domain of CLIP-170 is essential for interactions with KIF5B in the yeast two-hybrid assay. CLIP-170 bound to the cargo-binding domain of KIF5B. Also, other KIF5s, KIF5A and KIF5C, interacted with CLIP-170 in the yeast two-hybrid assay. In addition, glutathione S-transferase (GST) pull-downs showed that KIF5s specifically interacted with CLIP-170. An antibody to KIF5B specifically co-immunoprecipitated CLIP-170 associated with KIF5B from mouse brain extracts. These results suggest that kinesin 1 motor protein may transport CLIP-170 in cells.

EFFECT OF PRE-HEATING ON SOME PHYSICAL PROPERTIES OF COMPOSITE RESIN (중합 전 열처리가 복합레진의 일부 물성에 미치는 영향)

  • Jin, Myoung-Uk;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.30-37
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of pre-heating on some physical properties of composite resin. Eighty extracted, noncarious human molars were used in the present study. Four different temperatures of composite resin were used: $4^{\circ}C$, $17^{\circ}C$, $48^{\circ}C$, and $56^{\circ}C$. The $4^{\circ}C$ and $17^{\circ}C$ values represented the refrigerator storage temperature and room temperature respectively. For $48^{\circ}C$ and $56^{\circ}C$, composite resin was heated to the temperatures. As physical properties of composite resin, shear bond strength, microhardness, and degree of conversion were measured. The data for each group were subjected to one-way ANOVAs followed by the Tukey's HSD test at 95% confidence level. Both in enamel and dentin, among composite resin of $4^{\circ}C$, $17^{\circ}C$ $;48^{\circ}C$, and $56^{\circ}C$, the pre-heated composite resin up to $56^{\circ}C$ revealed the highest shear bond strength, and pre-heated composite resin to the higher temperature revealed higher shear bond strength. Microhardness value was also higher with composite resin of higher temperature. Degree of conversion was also higher with composite resin of the higher temperature. In this study, it seems that pre-heating composite resin up to the higher temperature may show higher shear bond strength, higher microhardness value, and higher degree of conversion. Therefore, when using composite resin in the clinic, preheating the composite resin could be recommended to have enhanced physical properties of it.

Influence of air abrasion and different dentin sealing techniques on microtensile bond strength to dentin (상아질의 봉쇄 시기와 표면처리 방법이 미세인장 결합강도에 미치는 영향)

  • Kang, Dong-Ho;Han, Chong-Hyun;Park, Jung-Won;Kim, Sun-Jai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.8-15
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effect of various methods of dentin bonding agent application and air abrasion pretreatment on microtensile bond strength between dentin and resin, using a self-etching adhesive system. Material and methods: Thirty freshly extracted human molars were obtained and divided into 6 groups of 5 teeth. A 2-step self etching adhesive system (Clearfil SE Bond) was used for all groups. The control specimens were prepared using a direct immediate bonding technique. The delayed dentin sealing specimens were prepared using an indirect approach without dentin prebonding. The immediate dentin sealing specimens were prepared using dentin prebonding immediately following preparation. Immediate dentin sealing teeth and delayed dentin sealing teeth had provisional restorations using Fermit for two weeks. Then all specimens of each group were divided into two groups of three, depending on air abrasion pretreatment. Composite "crowns" were incrementally built on and specimens were stored in water for 24 hours. All teeth were prepared for a microtensile bond strength test. Bond strength data were analyzed with a one-way ANOVA test, and post hoc comparison was done using the Scheffe's test. Results: The mean microtensile bond strengths of all groups were not statistically different from each other. Conclusion: When preparing teeth for indirect restorations, IDS and DDS with Clearfil SE bond, have no difference on the microtensile bond strength between dentin and resin. Air abrasion pretreatment did not affect the microtensile bond strength when using IDS and DDS with Clearfil SE bond.

Effect of specimen preparation method on the microtensile bond strength of veneering ceramic to zirconia (시편 제작 방법이 지르코니아 코어와 비니어링 세라믹의 미세 인장결합강도에 미치는 영향)

  • Kim, Ki-Yeon;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.114-119
    • /
    • 2011
  • The aim of this study was to investigate effect of specimen preparation method on the microtensile bond strength of veneering ceramic to zirconia core. Materials and methods: Cylindrical Lava zirconia block (3M ESPE, Seefeld, Germany) was cut into discs using a diamond disc. After sintering, the core specimens were placed in an adjustable mold and veneered with Lava ceram (3M ESPE, Seefeld, Germany). The disc shaped specimen of group 1 was cut into microbars ($1{\times}1{\times}7\;mm^3$) using a low speed diamond disc under water cooling (n = 15). The specimen of group 2 was cut into microbars ($1.2{\times}1.2{\times}7\;mm^3$) in the same way. Whereafter the microbars were trimmed ($1{\times}1{\times}7\;mm^3$) using a thick diamond disc under water cooling (n = 15). The microtensile bond strength was tested in a microtensile tester (Instron 8848, $Instron^{(R)}$ Co., Norwood, USA). Fractured microtensile specimens were analyzed under a stereomicroscope (MZ6, Leica Microsystems GmbH, Wetzlar, Germany) at magnification ${\times}30$. Results: The microtensile bond strength of group 1 ($28.8{\pm}7.0\;MPa$) was significantly higher than group 2 ($11.0{\pm}33\;MPa$) (P=.00). Conclusion: It appears advisable to avoid the trimming action, especially high strength ceramic specimens.

COMPARATIVE BOND STRENGTH OF SINGLE STEP ADHESIVES TO DIFFERENT DENTINAL DEPTHS (상아질의 깊이에 따른 단일 단계 접착제의 결합강도 비교)

  • Cho, Young-Gon;Jin, Cheol-Hee;Min, Jung-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.319-326
    • /
    • 2005
  • This study compared the microtensile bond strength $({\mu}TBS)$ of single step adhesives to different dentin depths. Superficial or deep dentin was exposed in 30 molar teeth by sectioning immediately under the DEJ or 1.5mm area from central pit, respectively. After polishing with 600-grit SiC paper, the dentin surfaces were assigned to three groups: AQ group-AQ Bond, L-Pop group-Adper Prompt L-Pop, Xeno group-Xeno III. The bonded specimens were sectioned into sticks and subjected to ${\mu}TBS$ testing with a crosshead speed of 1mm/minute. The results of this study were as follows; The ${\mu}TBS$ to superficial dentin was higher than that to deep dentin in all group. The ${\mu}TBS$ of Xeno group was significantly higher than that of L-Pop group and AQ group in both superficial and deep dentin (p<0.05).

The effect of adhesive thickness on microtensile bond strength to the cavity wall (와동벽에서 접착제의 두께가 미세인장 결합강도에 미치는 영향)

  • Lee, Hwa-Eon;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.9-18
    • /
    • 2007
  • The purposes of this study were to examine the variability of adhesive thickness on the different site of the cavity wall when used total-etch system without filler and simplified self-etch system with filler and to evaluate the relationship between variable adhesive thickness and microtensile bond strength to the cavity wall. A class I cavity in six human molars was prepared to expose all dentinal walls. Three teeth were bonded with a filled adhesive, $Clearfil^{TM}$ SE bond ana the other three teeth were bonded with unfilled adhesives, $Scotchbond^{TM}$ Multi Purpose. Morphology and thickness of adhesive layer were examined using fluorescence microscope. Bonding agent thickness was measured at three points along the axial cavity wall edge of cavity margin (rim). halfway down each cavity wall (h1f), internal angle of the cavity (ang). After reproducing the adhesive thickness at rim, h1f and ang, micro-tensile bond strength were evaluated. For both bonding agents, adhesive thickness of ang was significantly thicker than that of rim and h1f (P <0.05). As reproduced the adhesive thickness, microtensile bond strength was increased as adhesive thickness was increased in two bonding agents. Adhesive thickness of internal angle of the cavity was significantly thicker than that of the cavity margin and the halfway cavity wall for both bonding agents. Microtensile bond strength of the thick adhesive layer at the internal angle of the cavity was higher than that of the thin adhesive layer at 1,he cavity margin and the halfway cavity in the two bonding systems.