• Title/Summary/Keyword: 물질안전보건자료

Search Result 71, Processing Time 0.027 seconds

A Study for Pathological Observations on the HBr Combustion Toxity (병리학적 관찰을 통한 HBr의 연소 독성에 관한 연구)

  • Jo, Nam-Wook;Lee, In-Ku;Choi, Jae-Bum;Lee, Bong-Jae;Shin, Hyun-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.373-376
    • /
    • 2012
  • 건축 재료가 다변화됨에 따라 화재 시 발생되는 연소가스 또한 다양해지고 있다. 그중 HBr은 NES 713과 BS 6853에서 연소 가스의 독성 평가를 위해 측정되는 독성가스이다. 특히 산업안전물질보건자료(MSDS)에서는 HBr가스를 흡입할 경우 화상을 일으키며 호흡부전, 두통 등을 유발시킬 수 있고 50ppm의 HBr가스에 노출된 사람은 생명과 건강에 즉시 영향을 받을 수 있는 매우 유독한 연소가스이다. 본 논문에서는 HBr 표준가스를 사용하여 건축법에서 규정한 가스유해성 시험결과와 HBr가스에 노출된 mouse의 병리학적 관찰 결과를 비교 분석하여 HBr의 연소 독성에 관하여 연구를 진행하였다.

  • PDF

A Study on the Reduction of Falling Deaths Using 4M (4M을 활용한 떨어짐 사망사고 저감 방안 연구)

  • Kim, Seung Eun;Park, Jong Young;Kim, Young Kweon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.143-153
    • /
    • 2021
  • Purpose: The purpose of this study was to analyze data from the Ministry of Health, Safety and Health and the Ministry of Employment and Labor, and the total number of deaths (disease + accidents) reached 2,020 in 2019 and the estimated economic loss was 27.6 trillion won. This is believed to be the time to present improvements to ensure that economic loss estimates are steadily increasing as in Table 1, and that government-level losses can be drastically reduced. Method: In this study, factors were selected through prior research, and reliability analysis, technical statistics and correlation analysis, and multi-term analysis were conducted through the Jamovi program for the analysis of results. Result: Multiple session analysis was conducted to verify the research theory indicated in this study, and the analysis showed that mechanical and management factors did not affect the fall death accident of the opening, and human factors, material and environmental factors had a static effect. In addition, mechanical and administrative factors do not affect the fall of the outer wall, and human and material and environmental factors have a static effect. Conclusion:: As a result of analyzing 450 falling deaths over the past 13 years among the data posted to the Korea Health and Safety Corporation, the most common causes of falling deaths were the openings and outer walls.

A Study on Flammability Risk of Flammable Liquid Mixture (가연성 액체 혼합물의 인화 위험성에 관한 연구)

  • Kim, Ju Suk;Koh, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.701-711
    • /
    • 2020
  • Purpose: In this study, the risk of flammability of a liquid mixture was experimentally confirmed because the purpose of this study was to confirm the increase or decrease of the flammability risk in a mixture of two substances (combustible+combustible) and to present the risk of the mixture. Method: Flash point test method and result processing were tested based on KS M 2010-2008, a tag sealing test method used as a flash point test method for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was Japan's TANAKA. The flash point was measured with a test equipment that satisfies the test standards of KS M 2010 with equipment produced by the company, and LP gas was used as the ignition source and water as the cooling water. In addition, when measuring the flash point, the temperature of the cooling water was tested using cooling water of about 2℃. Results: First of all, in the case of flammable + combustible mixtures, there was little change in flash point if the flash point difference between the two substances was not large, and if the flash point difference between the two substances was low, the flash point tended to increase as the number of substances with high flash point increased. However, in the case of toluene and methanol, the flash point of the mixture was lower than that of the material with a lower flash point. Also, in the case of a paint thinner, it was not easy to predict the flash point of the material because it was composed of a mixture, but as a result of experimental measurement, it was measured between -24℃ and 7℃. Conclusion: The results of this study are to determine the risk of mixtures through experimental studies on flammable mixtures for the purpose of securing the effectiveness of the details of the criteria for determining dangerous goods in the existing dangerous goods safety management method and securing the reliability and reproducibility of the determination of dangerous goods Criteria have been presented, and reference data on experimental criteria for flammable liquids that are regulated in firefighting sites can be provided. In addition, if this study accumulates know-how on differences in test methods, it is expected that it can be used as a basis for research on risk assessment of dangerous goods and as a basis for research on dangerous goods determination.

Measurement and Prediction of Fire and Explosion Properties of n-Ethylanilne (노말에틸아닐린의 화재 및 폭발 특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Korean Chemical Engineering Research
    • /
    • v.56 no.4
    • /
    • pp.474-478
    • /
    • 2018
  • For process safety, fire and explosion characteristics of combustible materials handled at industrial fields must be available. The combustion properties for the prevention of the accidents in the work place are flash point, fire point, explosion limit, and autoignition temperature (AIT) etc.. However, the combustion properties suggested in the Material Safety Data Sheet (MSDS) are presented differently according to the literatures. The accurate combustion properties are necessary to safely treatment, transportation and handling of flammable substances. In the chemical industries, n-ethylaniline which is widely used as a raw material of intermediate products and rubber chemicals was selected. For safe handling of n-ethyl aniline, the flash point, the fire point and the AIT were measured. The lower explosion limit (LEL)of n-ethylaniline was calculated using the lower flash point obtained in the experiment. The flash points of n- ethylaniline by using the Setaflash and Pensky-Martens closed-cup testers measured $77^{\circ}C$ and $82^{\circ}C$, respectively. The flash points of n-ethylaniline using the Tag and Cleveland open cup testers are measured $85^{\circ}C$ and $92^{\circ}C$, respectively. The AIT of the measured n-ethyl aniline by the ASTM E659 apparatus was measured at $396^{\circ}C$. The LEL of n-ethylaniline measured by Setaflash closed-cup tester at $77^{\circ}C$ was calculated to be 1.02 vol%. In this study, it was possible to predict the LEL by using the lower flash point of n-ethylaniline measured by closed-cup tester. The relationship between the ignition temperature and the ignition delay time of the n-ethylaniline proposed in this study makes it possible to predict the ignition delay time at different ignition temperatures.

A Study on the Flammability and Combustion Risk of Biodiesel Mixture (바이오디젤 혼합물의 인화 및 연소 위험성에 관한 연구)

  • Kim, Ju Suk;Ko, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.10-24
    • /
    • 2021
  • Purpose: The purpose of this study is to determine the dangers of biodiesel and general diesel mixtures currently used as alternative fuels by equipment (tag method and penski Marten method) and to determine the difference between flash point and combustion point (closed, open) according to test methods. It is intended to be used as a reference material for identification and evaluation of firecausing substances by confirming the risk of mixtures by comparative analysis and measurement, and establishing a risk assessment method for chemical substances. Method: Flash point test method and result treatment were tested based on ASTM and KS M mode, which are tag sealing and pen schematense test methods used as flash point and combustion point test methods for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was a test equipment that satisfies the test standards of KS M 2010 with equipment produced by TANAKA of Japan. The flash point and combustion point were measured, and the flash point according to the test method of biodiesel and general diesel mixture ( Closed, open), and the ignition point of a mixture of biodiesel and general diesel was compared and analyzed for ignition risk compared with conventional diesel. Results: Looking at the experimental results, first, as an analysis of the risk of flammability of the mixture, the flash point of a substance containing 70% biodiesel was found to be about 92℃ based on general diesel with a flash point of 64.5℃, and gasoline and biodiesel or When the biodiesel mixture was synthesized, it was confirmed that the flash point tends to decrease. In addition, the difference between the flash point and the combustion point was analyzed as about 20 ~ 30℃, and when a small amount of gasoline or methanol was mixed, the flash point was lowered, but it was confirmed that the combustion point was similar to that of the existing mixture. Conclusion: In this study, in order to secure the effectiveness of the details of the criteria for judging dangerous materials in the existing Dangerous Materials Safety Management Act, and to secure the reliability and reproducibility of the judgment of dangerous materials, we confirm the criteria for judging the risk of the mixture through an experimental study on flammable mixtures. It will be able to provide reference data for experimental criteria for flammable liquids that are regulated in the field. In addition, if this study accumulates know-how on experiment by test method, it is expected that it can be used as a basis for research on risk assessment and research on dangerous goods.

Survey of Actual Conditions of Material Safety Data Sheet and Quantitative Risk Assessment of Toxic Substances : Substitutes for Degreasing Agents (일부 대체세정제 제조업체의 물질안전보건자료의 실태와 그 화학물질의 유해성 평가에 관한 연구)

  • Yoon, Chong-Guk;Jeon, Tae-Won;Chung, Chin-Kap;Lee, Myung-Hee;Lee, Sang-Il;Cha, Sang-Eun;Yu, Il-Je
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.2
    • /
    • pp.18-26
    • /
    • 2000
  • Since the regulation of MSDS (Material Safety Data Sheets) had started from July 1996, employers were required to furnish MSDS for the chemicals in use in their workplace. However, many MSDS did not contain upright information for the chemicals, and they were not updated regularly, and were not written in the standard format required by the Industrial Safety and Health Act (ISHA). The purposes of this study were 1) to examine the reliability of MSDS for mixed solvents, 2) to provide reliable MSDS to employers or employees, 3) to find out any difficulties in implementing MSDS after the initiation, and 4) to promote regular MSDS updating and to ensure the reliability of MSDS for chemical manufacturers. To check the reliability of MSDS of mixed chemicals, 21 samples of mostly degreasing solvents were collected along with their MSDS from the work place. The samples were analyzed by gas chromatography-mass selective detector(GC-MSD). Their components were classified as saturated hydrocarbon, cyclic hydrocarbon, aromatics, and halogen containing hydrocarbon, and the amount of each class were measured. Manufacture's MSDS were compared with the actual composition of the collected samples, and further examined the reliability by checking whether the chemicals analyzed were included in the MSDS correctly. Finally, each item of MSDS was evaluated whether the MSDS correspond to the regulation required by ISHA. The results were following: 1) most of the degreasing solvents in MSDS were incorrect in their composition and contents, 2) the information in the MSDS including hazard classification, exposure level, toxicity, regulatory information were incorrectly provided, and 3) some MSDS did not disclose carcinogens in their MSDS. Continuous monitoring of MSDS was required to ensure reliability of MSDS. The Chemicals containing hydrocarbons from C10-C15 need to be tested to provide toxicity data. In addition, governmental support for providing correct MSDS was recommended to ensure reliability of MSDS. The MSDS regulation relating to the confidential business information may need to be revised to ensure reliability of MSDS.

  • PDF

A Study on GHS Classification of 3-Methylpentane by Subacute Inhalation Toxicity (아급성흡입독성시험을 이용한 3-Methylpentane의 GHS 분류·표시)

  • Chung, Yong Hyun;Han, Jeong Hee;Shin, Seo Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.1
    • /
    • pp.6-17
    • /
    • 2017
  • Objectives : The purpose of this study was to obtain information regarding Globally Harmonized System(GHS) classification and health hazards that may result from a 4 weeks inhalation exposure of 3-Methylpentane in Sprague-Dawley rats. Methods : The testing method was conducted in accordance with OECD guidelines for the testing of chemicals No. 412(Subacute Inhalation Toxicity). The Rats were divided into 4 groups(5 male and 5 female rats in each group) and exposed to 0 ppm, 284 ppm, 1,135 ppm, 4,540 ppm 3-Methylpentane in each exposure chamber for 6 h/day, 5 days/week, for 4 weeks. After two weeks, the test animals were autopsied and carried out blood test and biochemical tests and histopathological examination. We used PRISTIMA (Toxicology data management system) to confirm the system and to have confidence of the raw data. Results : No death and particular clinical presentation including weight change and change of feed rate was observed. Relationship between dose, gender and response was also not significantly changed in hematologic examination, biochemical examination of blood and blood coagulation time. The histopathologic lesions caused by the test substance did not appear. Conclusions : NOAEL(No Observable Adverse Effect Level) of 3-Methylpentane is more than 4,540 ppm in male group and female group and the Ministry of Employment and Labor Guidance Announcement No. 2013-37(criteria for the classification marks and Safety of Chemicals) Specific target organ toxicity(repeated exposure) was determined with a substance that is not the separator material.

Reliability of Combustion Properties of MSDS(Material Safety Data Sheet) of tert-Amylalcohol(TAA) (tert-Amylalcohol(TAA)의 물질안전보건자료(MSDS) 연소특성치의 신뢰도)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.17-24
    • /
    • 2019
  • The combustion properties of the flammable substance used in industrial fields include lower/upper flash point, lower/upper explosion limit, autoignition temperature(AIT), fire point, and minimum oxygen concentration(MOC) etc.. The accurate assessment of these characteristics should be made for process and worker safety. In this study, tert-amylalcohol(TAA), which is widely used as a solvent for epoxy resins, oxidizers of olefins, fuel oils and biomass, was selected. The reason is that there are few researches on the reliability of combustion characteristics compared to other flammable materials. The flash point of the TAA was measured by Setaflash, Pensky-Martens, Tag, and Cleveland testers. And the AIT of the TAA was measured by ASTM 659E. The lower/upper explosion limits of the TAA was estimated using the measured lower/upper flash points by Setaflash tester. The flash point of the TAA by using Setaflash and Pensky-Martens closed-cup testers were experimented at 19 ℃ and 21 ℃, respectively. The flash points of the TAA by Tag and Cleveland open cup testers were experimented at 28 ℃ and 34 ℃, respectively. The AIT of the TAA was experimented at 437 ℃. The LEL and UEL calculated by using lower and upper flash point of Setaflash were calculated at 1.10 vol% and 11.95 vol%, respectively.

The Development of a Management System for the Safe Handling of Chemicals and Health Protection Using Reporting Data under the Chemical Control Act (화학물질관리법 조사·보고자료를 활용한 화학물질취급 안전보건관리에 대한 효율적인 체계 마련)

  • Jeon, DaYoung;Hwang, ManSik;Im, JiYoung;Ryu, JiSung;Kim, YoungHo;Lee, JiHo
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.2
    • /
    • pp.232-244
    • /
    • 2020
  • Objectives: The purpose of this study is to develop a management system for the safe handling of chemicals and related health management based on reporting under the Chemical Control Act (CCA). It is used to search handling information by constructing data linked to the name of companies, chemicals, products, etc. Methods: Due to the differences in submission periods for each reporting regulation of the Chemical Control Act, the data used is as follows: A statistical survey collected 26,222 companies in 2014 and 2016, Pollutant Release Transfer Registers (PRTR) collected 4,234 companies in 2015-2017, performance reports by handlers of hazardous chemical substances collected 14,658 companies in 2016-2018, and declarations for import of toxic chemicals collected 892 companies in 2016-2017. The total information on 36,080 companies is standardized based on company ID, name, business registration number, address, and more. The data were classified into information such as company, chemical, and product name and amounts handled and released, and then extracted according to criteria to establish relationships among classified information. Results: A search service was developed for handling information on chemical substances for reporting data by linking four reporting data: statistical survey, PRTR, performance report by handler of hazardous chemical substances, and declaration for import of toxic chemicals under the CCA. It was composed of five menus to search by regulation type, reporting regulation, companies and chemicals, and system management. Conclusion: It is necessary to use data linked by company, region, and chemical to respond and to prevent chemical accidents. In addition, these items can be utilized to perform handling and safety management of chemicals according to whether regulations under the CCA may be implemented.

Exposure of Carcinogens in Electronics Industries and Strategy for Control of Carcinogens: Using Work Environment Measurement Database (2013-2017) in Korea (한국 전자산업에서 작업환경측정을 통해 파악된 발암물질들 노출 특성과 발암물질관리 방안: 작업환경측정자료(2013-2017)를 중심으로)

  • Mia, Son;Jaewon, Yun;Yu Seoung, Hwang;Mijin, Park;MinSeo, Choi;Mi-Young, Lee;Domyung, Paek
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.4
    • /
    • pp.302-324
    • /
    • 2022
  • Objectives: The objective of this study is to investigate exposure to occupational carcinogens in the nationwide electronics industries and to establish a strategy for control of occupational carcinogens in South Korea. Methods: We evaluated occupational carcinogens as defined by International Agency for Research on Cancer (IARC) using a nationwide work environment measurement database on the electronics industry in South Korea measured between 2013 and 2017 in accordance with the Occupational Safety and Health Act. Results: The number of occupational carcinogens found in the electronics industry in South Korea were: 20 for IARC Group 1, 14 for Group 2A, and 30 for Group 2B. The occupational carcinogens (Group 1) most frequently exposed were strong-inorganic-acid mists containing sulfuric acid (sulfuric acid), welding fumes, mineral oils (untreated or mildly treated), nickel compounds, silica dust, crystalline substances in the form of quartz or cristobalite, formaldehyde, arsenic and inorganic arsenic compounds, chromium (VI) compounds, trichloroethylene, cadmium and cadmium compounds, vinyl chloride, ethylene oxide, wood dust, beryllium and beryllium compounds, 1,3 butadiene, benzene, and others. Among them, the carcinogens (Group 1) exceeding the acceptable standard were trichloroethylene, formaldehyde, and ethylene oxide. The working environment measurement system as regulated by Occupational Safety and Health Act is not properly assessed and managed for occupational carcinogens in South Korea. A component analysis for all materials used should be set up to practically reduce occupational carcinogens. A ban on the use of occupational carcinogens and the development of alternative materials are needed. The occupational carcinogens below the acceptable standards should be carefully examined and a new standard for exposure needs to be established. Conclusions: The Occupational Safety and Health Act should be improved to identify and monitor occupational carcinogens at work sites. A strategy for occupational safety and health systems should be provided to give direction to workers' needs and right to know.