• Title/Summary/Keyword: 무게(mass)

Search Result 311, Processing Time 0.023 seconds

A Study on Tetrahedron's Properties related with Center of Inscribed Sphere Using the Center of Mass (무게중심을 이용한 사면체 내접구의 중심에 관련된 성질 탐구)

  • Han, In-Ki
    • Communications of Mathematical Education
    • /
    • v.24 no.1
    • /
    • pp.145-158
    • /
    • 2010
  • In this paper we study tetrahedron's properties related with center of inscribed sphere using the center of mass. We show that the center of mass of four mass points (A,a), (B,b), (C,c), (D,d) coincide with center of tetrahedron's inscribed sphere, suggest equalities and inequalities related with center of inscribed sphere, and prove theses using the center of mass. Our results can be used in research and education programs, various types of gifted student education.

Prediction of Kick Motor Mass Variation (킥모터 무게 변화 예측)

  • Kil, Gyoung-Sub;Kho, Hyeon-Seok;Kim, Byung-Hun;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.203-206
    • /
    • 2008
  • Kick motor(KM) for KSLV-I second stage propulsion system is the main hardware that is necessary for launching satellite to it's track. The mass of the kick motor changes with combustion time because the heat insulator is ablated and propellant is used and slag is piled up. We predicted mass change with the flight time using ground combustion data of KM composed of case, propellant, nozzle, ignitor and slag. The mass prediction of kick motor can be used for calculating the two stage mass and center of gravity history.

  • PDF

우주환경하에서의 진동자의 주파수 변화 측정에 의한 질량 측정 시스템 및 방법

  • Kim, Youn-Kyu;Kim, Jong-Woo;Kim, Kwong-Sik;Choi, Gi-Hyuk
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.216-219
    • /
    • 2005
  • In this study, we will explain the design, test results and analysis of system for measuring the small mass in the microgravity environment. It is so difficult to measure the mass by sensing the gravity as the ground in the microgravity environment. The suggested method is to measure the resonance frequency of a sample. The resonance frequency may be measured as a function of mass. If we know the resonance frequency of the mass, we can guess the mass by detecting the resonance frequency. Piezoelectric ceramics have the characteristics that resonance frequency is changed by total mass which are its mass and the attached mass. This system have some problems but we verified that we can measure the unknown mass using the resonance frequency as the mass.

  • PDF

Motion generation using Center of Mass (무게중심을 활용한 모션 생성 기술)

  • Park, Geuntae;Sohn, Chae Jun;Lee, Yoonsang
    • Journal of the Korea Computer Graphics Society
    • /
    • v.26 no.2
    • /
    • pp.11-19
    • /
    • 2020
  • When a character's pose changes, its center of mass(COM) also changes. The change of COM has distinctive patterns corresponding to various motion types like walking, running or sitting. Thus the motion type can be predicted by using COM movement. We propose a motion generator that uses character's center of mass information. This generator can generate various motions without annotated action type labels. Thus dataset for training and running can be generated full-automatically. Our neural network model takes the motion history of the character and its center of mass information as inputs and generates a full-body pose for the current frame, and is trained using simple Convolutional Neural Network(CNN) that performs 1D convolution to deal with time-series motion data.

Kinematic Characteristics of the Thrower's COM and the Shot in Shot Put : The Woman Record Holder of Korea (포환던지기 동작 시 포환과 신체 무게중심의 운동학적 특성 : 한국 여자 기록보유자를 대상으로)

  • Lee, Dong-Jin;Cho, Byung-Jun;Lee, Myung-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5148-5154
    • /
    • 2012
  • The purpose of this study was to analyze the kinematic characteristics of the thrower's center of mass (COM) and the shot that her performance hits record high for the 29th National Athletic Competition. Two S-VHS video cameras were used to visualize. The Direct Linear Transformation technique was employed to paint a clear picture in the three dimensional coordination. Kwon3D was used to analyze the data. The results showed that release velocity and height were 13.73 m/s and 198.6 cm(119% by height ratio), respectively, which is considered as peak performance comparing an extensive review of previous literature on the shot put. Release angle was $34^{\circ}$, which is lower than the previous studies. The path of thrower's center of mass is needed to travel in a release direction during the flight phase. The vertical movement of the thrower's center of mass during the driving should be controlled. At release, the perfact timing is required without vertical and horizontal movements of the thrower's center of mass.

An Analysis of Elementary Mathematics and Science Textbooks for Grades 3 and 4: Focused on Capacity, Volume, Weight, and Mass (초등학교 3~4학년군 수학·과학 교과서 비교 분석: 들이, 부피, 무게, 질량을 중심으로)

  • Pang, JeongSuk;Kwon, MiSun
    • School Mathematics
    • /
    • v.19 no.3
    • /
    • pp.617-638
    • /
    • 2017
  • In order to make a connection in teaching similar concepts between mathematics and science in teaching similar concepts, this paper analyzed the contents related to capacity, volume, weight, and mass in the mathematics and science textbooks aligned with the national elementary curriculum. We first explored when to present such topics in both textbooks, and then analyzed in what ways the topics were addressed in terms of quantitative comparison, vocabulary, units of measurement, measurement, tools for measurement, estimation, and connections to real life. The results of this study showed that there were some aspects emphasized in common both in mathematics and science textbooks. The analysis of this study also demonstrated subtle but considerable differences according to the characteristics of two subject matters. Based on these results, this paper provides implications for elementary school teachers to consider in teaching capacity, volume, weight, and mass through mathematics and science lessons.

A Study on n FBG Weight Sensor (광파이버 브래그 격자형 무게 센서에 관한 연구)

  • Lee, Jong-Jong;Jung, Jin-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.721-725
    • /
    • 2007
  • A fiber optic based weight sensor has fabricated using a fiber Bragg grating with a weight sensitive. The sensing concept exploits the inherent characteristics of the FBG and is based on the strain effect induced in the fiber Bragg grating through. A direct indication of the weight level is given by the shift of the Bragg wavelength caused by the expansion of the sensing material. A FBG behaves like a spectral filter which has inherent characteristics that render it very sensitive to strain and temperature. The sensing principle is also based on the strain effect induced in the FBG through the caused by the weight. The experimental setup used for the initial investigation to characterize the mass response of the sensor. The transmitted signal from the sensor was monitored using an optical spectrum analyzer with a resolution bandwidth of 0.4nm. In this paper, we presented the spectral characterization and shaping of FBG by scanning a mass element that affects a small grating fraction at a time, without permanent effects on the optical fiber when the various wavelength and strain is removed. That is, destruction when the optical fiber for weight is physically damaged.

  • PDF

Estimation of Mass Size Distribution of Atmospheric Aerosols Using Real-Time Aerosol Measuring Instruments (실시간 에어로졸 측정장비를 이용한 대기 중 입자상 물질의 무게 농도 분포의 추정)

  • Ji, Jun-Ho;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.39-50
    • /
    • 2013
  • Real-time aerosol measuring instruments have been widely used for the measurement of atmospheric aerosol, diesel particulate matter, or material synthesis. A scanning mobility particle sizer (SMPS) measures the number size distribution of particles using electrical mobility detection technique. An aerodynamic particle sizer (APS) is used to determine the number concentration and the mean aerodynamic diameter of test particles. An electrical low-pressure impactor (ELPI) is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. In this study, the performance of these instruments were evaluated to assess their ability to obtain mass concentrations from particle number concentration measurements made as a function of particle size. The effect of determination of particle density on the measurement of mass concentration was investigated for the three instruments.

Effect of Seed Weight and Storage Method on Germination and Seedling Growth of Camellia japonica (동백나무의 발아 및 유묘 생장에 미치는 종자 무게 및 저장방법의 영향)

  • Kang, Hee-Kyoung;Choi, Su-Ji;Song, Hong-Seon
    • Korean Journal of Plant Resources
    • /
    • v.33 no.1
    • /
    • pp.33-39
    • /
    • 2020
  • This study was carried out to provide basic information for mass breeding and cultivating the saplings of Camellia japonica. The germination rates did not show definite tendency according to the changes of seed weight at room temperature and 4℃ dry storage conditions. The germination rate of 4℃ wet sand storage was increased with seed weight, but showed very low germination rate for 120 days of storage. The germination rate was above 80% in 60 days, 90 days and 120 days, respectively, at 4℃ wet filter paper storage conditions. The average days taken for those germinations were about 30 days at room temperature and 4℃ dry storage conditions, but wet storage (sand, filter paper) condition took the shortly nearly 13 days for those germinations. Leaf number, leaf dry weight, stem diameter and root dry weight were higher than total average by more than 1.21 g for seed weight. Stem length was higher than the average by more than 1.01 g, plant dry weight was higher than the average by more than 0.81 g, and stem dry weight was higher than the average by more than 0.61 g. In the case of seed weight becoming heavier, seedling growth was good but T/R ratio tended to decrease. In order to increase the mass production of seedlings using Camellia japonica seeds, we need to specify the weight and size of those seeds. The 4℃ wet filter paper storage condition was evaluated as the most efficient method for the seed storage used for seeding.

Effects of Prosthetic Mass Distribution on Musculoskeletal System during Amputee Gait (의지 보행시 의지 무게 분포가 근골격계에 미치는 영향)

  • Bae, Tae-Soo;Choi, Hwan;Kim, Shin-Ki;Mun, Mu-Seong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.8 s.197
    • /
    • pp.130-137
    • /
    • 2007
  • The optimized prosthetic mass distribution was a controversial problem in the previous studies because they are not supported by empirical evidence. The purpose of the present study was to evaluate the effect of prosthetic mass properties by modeling musculoskeletal system, based on the gait analysis data from two above-knee amputees. The joint torque at hip joint was calculated using inverse dynamic analysis as the mass was changed in knee and foot prosthetic components with the same joint kinematics. The results showed that the peak flexion and abduction torque at the hip joint were 5 Nm and 15 Nm when the mass of the knee component was increased, greater than the peak flexion and abduction torque of the control group at the hip joint, respectively. On the other hand, when the mass of the foot component was increased, the peak flexion and abduction torque at the hip joint were 20 Nm and 15 Nm, greater than the peak flexion and abduction torque of the control, respectively. The hip flexion torque was 4.71-fold greater and 7.92-fold greater than the hip abduction torque for the knee mass increase and the foot mass increase on the average, respectively. Therefore, we could conclude that the effect of foot mass increase was more sensitive than that of knee mass increase for the hip flexion torque. On the contrary, the mass properties of the knee and foot components were not sensitive for the hip abduction torque. In addition, optimized prosthetic mass and appropriate mass distributions were needed to promote efficiency of rehabilitation therapy with consideration of musculoskeletal systems of amputees.