Browse > Article

Effects of Prosthetic Mass Distribution on Musculoskeletal System during Amputee Gait  

Bae, Tae-Soo (재활공학연구소, 인체공학팀)
Choi, Hwan (고려대학교 제어시스템공학)
Kim, Shin-Ki (재활공학연구소, 인체공학팀)
Mun, Mu-Seong (재활공학연구소, 인체공학팀)
Publication Information
Abstract
The optimized prosthetic mass distribution was a controversial problem in the previous studies because they are not supported by empirical evidence. The purpose of the present study was to evaluate the effect of prosthetic mass properties by modeling musculoskeletal system, based on the gait analysis data from two above-knee amputees. The joint torque at hip joint was calculated using inverse dynamic analysis as the mass was changed in knee and foot prosthetic components with the same joint kinematics. The results showed that the peak flexion and abduction torque at the hip joint were 5 Nm and 15 Nm when the mass of the knee component was increased, greater than the peak flexion and abduction torque of the control group at the hip joint, respectively. On the other hand, when the mass of the foot component was increased, the peak flexion and abduction torque at the hip joint were 20 Nm and 15 Nm, greater than the peak flexion and abduction torque of the control, respectively. The hip flexion torque was 4.71-fold greater and 7.92-fold greater than the hip abduction torque for the knee mass increase and the foot mass increase on the average, respectively. Therefore, we could conclude that the effect of foot mass increase was more sensitive than that of knee mass increase for the hip flexion torque. On the contrary, the mass properties of the knee and foot components were not sensitive for the hip abduction torque. In addition, optimized prosthetic mass and appropriate mass distributions were needed to promote efficiency of rehabilitation therapy with consideration of musculoskeletal systems of amputees.
Keywords
Prosthetic gait; Prosthetic mass distribution; Musculoskeletal model; Dynamic simulation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Winter, D. A. and Sienko, S. E., 'Biomechanics of below-knee amputee gait,' Journal of Biomechanics, Vol. 21, Issue 5, pp. 361-367, 1998   DOI   ScienceOn
2 Loan, P. J., 'Dynamics Pipeline,' Evanston IL, Musculographics., 1992
3 Sanderson, D. J. and Martin, P. E., 'Lower extremity kinematic and kinetic adaptations in unilateral below-knee amputees during walking,' Gait and Posture, Vol. 6, pp. 126-136, 1997   DOI   ScienceOn
4 Delp, S. L. and Loan, J. P., 'A computer-graphics software system to develop and analyze models of musculoskeletal structures,' Computers in Biology and Medicine, Vol. 25, Issue 1, pp. 21-34, 1995   DOI   ScienceOn
5 Zajac, F. E., 'Muscle and Tendon: Properties, Models, Scaling, and Application to Biomechanics and Motor Control,' CRC Crit. Revs. Biomed. Eng., Vol. 17, Issue 14, pp. 359-411, 1989
6 Mattes, S. J., Martin, P. E. and Royer, T. D., 'Walking symmetry and energy cost in persons with unilateral transtibial amputations: matching prosthetic and intact limb inertial properties,' Archives of Physical Medicine and Rehabilitation, Vol. 81, No. 5, pp. 561-568, 2000   DOI   ScienceOn
7 Winters, D. A., 'Anthropometry, In: David A. Winter, Biomechanics and Motor Control of Human Movement,' John Wiley & Sons, pp. 51-74, 1990
8 Kingma, I., Toussaint, H. M., De Looze, M. P. and Van Dieen, J. H., 'Segment inertial parameter evaluation in two anthropometric models by application of a dynamic linked segment model,' Journal of Biomechanics, Vol. 29, Issue 5, pp. 693704. 1996   DOI   ScienceOn
9 Wickiewicz, T. L., Roy, R. R., Powell, P. L., Perrin, J. J. and Edgerton, V. R., 'Muscle architecture and force-velocity relationships in humans,' Journal of Applied Physiology. Respiratory, Environmental and Exercise Physiology, Vol. 57, Issue 2, pp. 435-443, 1984
10 Yamaguchi, G. T., 'Models of the skeletal system, dynamic equation of motion and control,' In Dynamic Modeling of Musculoskeletal Motion, pp. 143-237, 2001
11 Brand, R. A., Pedersen, D. R. and Friederich, J. A., 'The sensitivity of muscle force predictions to changes in physiologic cross-sectional area,' Journal of Biomechanics, Vol. 19, Issue 8, pp. 589596, 1986   DOI   ScienceOn
12 Beck, J. C. and Czerniecki, J., 'A method for optimization of above-knee prosthetic shank-foot inertial characteristics,' Gait and Posture, Vol. 2, pp. 75-84, 1994   DOI   ScienceOn
13 Selles, R. W., Bussmann, J. B., Wagenaar, R. C. and Stam, H. J., 'Effects of prosthetic mass and mass distribution on kinematics and energetics of prosthetic gait: a systematic review,' Archives of Physical Medicine and Rehabilitation, Vol. 80, No. 12, pp. 1593-1599, 1999   DOI   ScienceOn