The Dynamics Responses of Railway Bridges Considering the Track Model (궤도모형에 따른 철도교량의 동적응답분석)

  • Kim, Sang-Hyo;Lee, Yong-Seon;Jung, Jun;Lee, Jun-Suk
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.715-720
    • /
    • 2002
  • The dynamic load effects, generated by moving trains, are transferred to the railway bridges through tracks. The dynamic load effects may vary due to the dynamic characteristics of the applied vehicle loads and the railway bridges including the track system. However, the track models have been neglected or simplified by spring elements in the most studies since it is quite complicated to consider the track systems in the dynamic analysis models of railway bridges. In this study track system on railway bridges are modeled using a three-dimensional discrete-support model that can simulate the load carrying behavior of tracks. A 40m simply supported prestressed concrete box-girder system adopted for high-speed railway bridges are modeled for simulation works. The train models are composed of 20 cars for KTX. The dynamic response of railway bridges are found to be affected depending on whether the track model is considered for not. The influencing rate depends on the traveling speed and different wheel-axle distance. The dynamic bridge response decreases remarkably by the track systems around the resonant frequency. Therefore, the resonance effect can be reduced by modifying the track properties in the railway bridge, especially for KTX trains.

  • PDF

Neural Net Application Test for the Damage Detection of a Scaled-down Steel Truss Bridge (축소모형 강트러스 교량의 손상검출을 위한 신경회로망의 적용성 검토)

  • Kim, Chi-Yeop;Kwon, Il-Bum;Choi, Man-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.4
    • /
    • pp.137-147
    • /
    • 1998
  • The neural net application was tried to develop the technique for monitoring the health status of a steel truss bridge which was scaled down to 1/15 of the real bridge for the laboratory experiments. The damage scenarios were chosen as 7 cases. The dynamic behavior, which was changed due to the breakage of the members, of the bridge was investigated by finite element analysis. The bridge consists of single spam, and eight (8) main structural subsystems. The loading vehicle, which weighs as 100 kgf, was operated by the servo-motor controller. The accelerometers were bonded on the surface of 7 cross-beams to measure the dynamic behavior induced by the abnormal structural condition. Artificial neural network technique was used to determine the severity of the damage. At first, the neural net was learnt by the results of finite element analysis, and also, the maximum detection error was 3.65 percents. Another neural net was also learnt, and verified by the experimental results, and in this case, the maximum detection error was 1.05 percents. In future study, neural net is necessary to be learnt and verified by various data from the real bridge.

  • PDF

Improvement of Nash's instantaneous unit hydrograph model for estimating design flood of ungauged mid-/small watersheds (미계측중소유역에서의 설계홍수량산정을 위한 Nash 순간단위도모델 개선)

  • Kang, Boo-Sik;Kim, Jong-Min;Kim, Jin-Gyeom
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.946-946
    • /
    • 2012
  • 현재 국내 하천의 설계홍수량은 하천정비 기본계획이나 유역종합 치수계획 등을 통하여 고시 되고 있다. 이러한 설계홍수량은 홍수량 산정 지침에 따라 산정되며, 최종적으로 결정된 설계홍수량을 기준으로 하도계획이나 교량, 암거 등의 설계를 실시하였다. 현재 많은 수의 홍수조절용 다목적 댐과 강변저류지 등 각종 수리조작 구조물들이 축조되면서부터 홍수량을 시간별로 조절할 수 있게 되었지만, 미계측 유역에서는 유역의 유출량을 예측하기가 쉽지 않기 때문에 수리조작 구조물들의 효과를 예상하고 조작 및 운영방법을 결정하기 어려운 실정이다. 이러한 이유로, 본 연구에서는 미계측 유역 내 축조하는 수공 구조물의 최적 설계 및 운영방법 결정을 위하여 설계홍수량과 함께 합성단위도법을 적용한 수문곡선을 적용할 수 있도록 Nash 모형을 이용하였다. 유역의 유출특성이 반영된 대표단위도를 산정하기 위해 여러 유역의 다양한 형상계수를 이용하여, 도달시간과 첨두유량에 관한 회귀식을 산정하였다. 이렇게 산정된 회귀식을 여러 형태의 유역과 강우-유출 사상에 적용하여, 미계측 유역의 특정지점에서 발생의 개연성이 충분하고 수공구조물의 설계와 효과에 가장 중요하게 영향을 미칠 수 있는 설계홍수수문곡선을 도출하는 것을 목적으로 하였다. 본 연구의 결과로 나타나는 대표홍수수문곡선을 미계측 유역에 적용한다면 미지의 설계홍수량을 추정함과 동시에 설계홍수량에 상응하는 수문곡선을 도출하여 수공구조물 설계에 이용할 수 있을 것이라 기대한다.

  • PDF

Development of Design Flood Hydrograph Simulator for Flood Control Assessment of Side-weir Detention Basin (강변저류지의 치수평가를 위한 설계홍수수문곡선 시뮬레이터 개발)

  • Kang, Boo-Sik;Kim, Jin-Gyeom;Kim, Jong-Min;Yoon, Byeong-Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.947-947
    • /
    • 2012
  • 현재 국내 하천의 설계홍수량은 하천정비 기본계획이나 유역종합 치수계획 등을 통하여 특정 빈도의 단일 홍수량의 형태로 고시되고 있다. 이러한 설계홍수량은 홍수량 산정 지침에 따라 산정되며, 최종적으로 결정된 설계홍수량을 기준으로 하도계획이나 교량, 암거 등의 설계를 실시하였다. 하지만 많은 수의 홍수조절용 다목점 댐과 강변저류지 등 각종 수리조작 구조물들이 축조되면서부터 홍수량을 시간별로 조절할 수 있게 되었다. 따라서 종전과 같이 단일 설계홍수량 값만으로는 신설되는 수리조작 구조물의 최적 규모 및 운영방법을 결정하는데 어려움이 있다. 이러한 이유로, 본 연구에서는 Nash 모형을 사용하여 특정유역의 유출특성이 반영된 대표단위도를 산정하고 여러 가지 형태의 강우사상에 적용하여, 유역의 특정지점에서 특정홍수량에 대하여 발생의 개연성이 충분하고 수공구조물의 설계와 효과에 가장 중요하게 영향을 미칠 수 있는 설계 홍수수문곡선을 산정하는 것을 목적으로 하며, 일련의 과정을 프로그램화 시켜 실무적으로 활용될 수 있도록 하였다. 본 연구의 결과로 나타나는 설계홍수수문곡선은 곡선의 첨두부와 형상에 따라, 동일한 규모의 수공구조물 일지라도 그 효과가 달라지기 때문에 수공구조물의 효과를 최대로 하기위한 구조물 형태와 조작 및 운영방법을 결정하는데 도움이 될 것이다.

  • PDF

Analysis of Hydraulic effects on Piers and Transverse Overflow Type Structures in Urban Stream (도시하천의 교각 및 횡단 월류형 구조물에 의한 수리영향 분석)

  • Yoon, Sun-Kwon;Chun, Si-Young;Kim, Jong-Suk;Moon, Young-Il
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.2
    • /
    • pp.197-212
    • /
    • 2008
  • Recently, stream flow analysis has been accomplished by one or two dimensional equations and was applied by simple momentum equations and fixed energy conservations which contain many condition limits. In this study, FLOW-3D using CFD (Computational Fluid Dynamics) was applied to stream flow analysis which can solve three dimensional RANS (Reynolds Averaged Navier-Stokes Equation) control equation to find out physical behaviors and the effect of hydraulic structures. Numerical simulation accomplished those results was compared by using turbulence models such as ${\kappa}-{\varepsilon}$, RNG (Renormalized Group) ${\kappa}-{\varepsilon}$ and LES (Large Eddy Simulation). Numerical analysis results have been illustrated by the turbulence energy effects, velocity of flow, water level pressure and eddy flows around the piers and transverse overflow type structures. These results will be able to used by basis data that catch hold of effects on long-term bed elevation changes, sediment accumulations, scours and water aggravations by removal of obsolete transverse over flow type structures in urban stream.

Evaluation of Suction Installation for the Circular Pipe into Low-water Sandy Ground via Model Test (모형실험을 활용한 저수심 사질토 지반에서 원형강관 설치 석션압 평가)

  • Xin, Zhen-Hua;Kim, Jae-Hyun;Lee, Ju-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.1-10
    • /
    • 2021
  • In this study, a circular pipe can be installed by suction pressure for construction on soft ground with a low-water level. A series of laboratory-scale model tests were conducted in sandy ground to comprehend the suction pressure of the circular pipe in low-water levels. For repeated tests on saturated sandy soil, a container was mounted with three vibration generators on the floor. A repetitive vibration was applied using the vibration system for ground compaction. In the model tests, different diameters and thicknesses on saturated sandy soil with a water depth were considered. The result showed that the suction pressure increased with increasing penetration depth of the circular pipe. Moreover, the suction pressure required to penetrate the pipe decreased with increasing diameter. In the low-water level, the total suction pressure measured at the top lid increased because additional suction pressure is required to lift the water column. On the other hand, this led to a decrease in suction pressure to penetrate the circular pipe because the weight of the water column is applied as a dead load. Therefore, it is necessary to consider the water level to design the required suction pressure accurately.

Developments of Advanced Connection Type for Improvements of Mixed Structures(I) : 3D Nonlinear Analysis of the Various Connection Types for Deriving Advanced Connection Type (혼합구조의 성능 향상을 위한 개선된 접합방식의 개발 (I) : 개선된 접합방식을 도출하기 위한 3차원 비선형 해석)

  • Yun, Ik Jung;Huh, Taik Nyung;Kim, Moon Kyum;Cho, Sung Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1A
    • /
    • pp.89-94
    • /
    • 2008
  • The problem of interaction between the structures interconnected at discrete points as like composite structures, has a attracted considerable attention for a prolonged period of time. Recently, mixed structures are applied for overcoming structural limits by developed countries. In this paper, advanced connection type of mixed structures are presented by numerical approach. Also it is performed on extensive literature review from theoretical method to numerical analysis. For analysing behaviors of mixed structures according to connection type, 2 different connections and 1 reinforced connection are compared by 3D nonlinear numerical analysis. Nonlinear analysis of mixed structures is carried out by utilizing contact elements of a general purpose structural analysis computer program(ABAQUS). By using 6 criteria, each connections are investigated. From this result, proper reinforcing and well designed connection type are proposed. And results also show that the deflections which are induced by discontinuity on mixed structures, has a linear distribution that should decrease as applying proposed connection type.

Effects of Lateral Bracing on the Load Distribution and Torsional Behaviors in Continuous Two-Girder Bridges (연속 2-거더교에서 수평브레이싱이 하중 분배 및 비틂 거동에 미치는 영향)

  • Hwang, Min Oh;Yoon, Tae Yang;Park, Yong Myung;Joe, Woom Do Ji;Hwang, Soon Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.671-680
    • /
    • 2007
  • In this study, we performed a loading test to evaluate the effect of load distribution on continuous two-span plate-girder bridges with or without bottom lateral bracing using one-fifth-scale bridge specimens. From the test results, when specimens with lateral bracing were loaded eccentrically, the load distribution capacity of the concrete deck and cross beam improved and greater loading was distributed to the other side of the girder subjected to loading. The load distribution rate of the specimens with and without lateral bracing system was evaluated from the analytical model that was verified by the test results. From the result of the quantitative evaluation, when specimen without lateral bracing was loaded eccentrically, mostly 21% of loading according to the concrete deck was distributed to the other side of the girder subjected to loading. However, when specimen with lateral bracing was loaded eccentrically, the load distribution rate increased by 1.7 times as all cross beams, bracing and concrete deck participated in load distribution. The reason is that the torsional rigidity increased as the model with lateral bracing behaved like a pseudo-closed box section.

An Effective Application of AE Technique for the Detection of Defects in Steel Girder Bridges (강판형교에서의 효율적인 결함검출을 위한 AE기법의 적용)

  • Kim, Sang Hyo;Yoon, Dong Jin;Lee, Sang Ho;Kim, Hyung Suk;Park, Young Jin
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.287-300
    • /
    • 1997
  • In this study, an effective application method of AE technique for the detection of fatigue crack in multi-girder steel bridges has been proposed. The applicability has been examined through the laboratory works with bridge model. The proposed analytical method which evaluates the remaining fatigue lives of structural members may improve the rational determination of the priority of inspection for structural members assuming to have fatigue cracks. Laboratory tests for the application of AE technique to steel girder bridges show that the frequency bands of traffic noise are in the range between 10 show that the frequency bands of traffic noise are in the range between 100~200 kHz and the AE signal raised from fatigue cracks is concentrated around 400~500 kHz. Therefore. R30 sensor is proved to be the most suitable for the detection of cracks in steel girder bridges. A linear proportionality between the crack propagation and the frequency of AE signals has been obtained. In addition, an economic and effective source location method for steel girder bridges was studied through experiments.

  • PDF

A Study on the Experiment of Represtressed Preflexional Composite Beams (RPF 합성보의 실험 연구)

  • Chang, Dong Il;Hwang, Yoon Kook;Kim, Jung Ho;Cho, Tae Jun
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.697-705
    • /
    • 1997
  • The conventional preflex beams are designed by the method of paritial prestressing and allow the tensile stresses at the lower concrete of beams. As a consequence, most of preflex beams experience the tensile cracks under the service loads. This study was conducted to develop the most effective preflex beams, which do not allow tensile stress under the service load, by introducing additional prestressing called 'represtressing' at the lower concrete of beams. The objective of the study was accomplished by developing a computer analysis and design program and conducting experiments. Using the developed computer program, standard sections of the represtressed preflex beams were determined by computer modeling. In the experiment, two actual size of represtressed beams were tested under the imitated service loads. The results of test have shown that the performance of the represtressed preflex beams is generally excellent. A remarkable improvement was made in the design of preflex composite beams. Since the represtressed preflex beams(RPF) do not experience the tensile cracks under the service loads, the use of this beam for the bridge structures will lead to easy bridge maintenance and management. Furthermore, due to the low beam depth, high clearance and economical design can be realized in the bridge design using RPF.

  • PDF