Abstract
In this study, we performed a loading test to evaluate the effect of load distribution on continuous two-span plate-girder bridges with or without bottom lateral bracing using one-fifth-scale bridge specimens. From the test results, when specimens with lateral bracing were loaded eccentrically, the load distribution capacity of the concrete deck and cross beam improved and greater loading was distributed to the other side of the girder subjected to loading. The load distribution rate of the specimens with and without lateral bracing system was evaluated from the analytical model that was verified by the test results. From the result of the quantitative evaluation, when specimen without lateral bracing was loaded eccentrically, mostly 21% of loading according to the concrete deck was distributed to the other side of the girder subjected to loading. However, when specimen with lateral bracing was loaded eccentrically, the load distribution rate increased by 1.7 times as all cross beams, bracing and concrete deck participated in load distribution. The reason is that the torsional rigidity increased as the model with lateral bracing behaved like a pseudo-closed box section.
본 연구에서는 연속 2-거더교에서 하부 수평브레이싱의 유 무에 따른 하중분배효과를 파악하기 위하여 실제 교량으로부터 1/5 축소 제작된 모형 교량을 이용하여 재하 실험을 수행하였다. 실험 결과에 의하면 편재하된 하중에 대해 수평브레이싱이 설치되면 바닥판과 가로보의 구조적 기능이 향상되어 하중의 분배효과가 증가하는 것으로 나타났다. 한편, 해석모델을 사용하여 수평브레이싱 유 무에 따른 하중분배율을 정량적으로 평가해 본 결과, 수평브레이싱이 미설치된 경우는 대부분 바닥판에 의해 편재하 하중의 21% 정도가 반대측 거더로 전달되었고, 설치된 경우는 가로보와 브레이싱, 그리고 바닥판 모두 하중분배에 기여하여 하중분배효과가 1.7배 정도 증가하는 것으로 나타났다. 이는 수평브레이싱이 설치로 인해 가로보와 바닥판, 그리고 수평브레이싱 부재가 유사폐합단면을 구성하여 시험체의 비틂 강성이 증가되기 때문으로 분석되었다.