• Title/Summary/Keyword: 모사도 제작

Search Result 552, Processing Time 0.031 seconds

A Study on the Indirect Copy of Dancheong Patterns Using Three-dimensional Scanning (3차원 스캐닝을 활용한 단청문양의 간접전사 연구)

  • An, Ji Eun;Choi, Chan Ho;Kim, Sung June;Yoon, Man Young
    • Journal of Conservation Science
    • /
    • v.34 no.6
    • /
    • pp.471-479
    • /
    • 2018
  • Seonunsa Temple is a site of Dancheong cultural significance in Daewoongjeon. Three-dimensional (3D) scanning can be used to create a simulation in 1:1 ratio without touching the Dancheong patterns directly. The traditional method of recreating Dancheong was paining with tracing paper using a fix pin. However, manual direct copy processes can cause and damage to the objects. This study shows the results of a simulation of a tranditional Dancheong patterns as an alternative; the simulation was able to reduce dimensional errors and prevent damage by using 3D scanning. As a result, objective and precise proportions of the simulation were acquired. The 3D scanning method may be applied for work such as the replication and restoration of the drawing, 3D fabrication of the original data, and printing of the additional drawing. In addition, with the production of 3D materials, a virtual museum is possible.

Simulant Gel Propellant Characteristics depending on Mixing Method (제작방법에 따른 모사 젤 추진제의 특성 연구)

  • Kim, Jae-Woo;Jun, Doo-Sung;Shin, Woong-Sup;Lee, Hyo-Mi;Moon, Hee-Jang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.467-470
    • /
    • 2011
  • In this study, two different kind of impeller, commercial hand blender and manual type were used to investigate the most effective mixing method for simulant gel propellant. Ionized Water, Carbopol 941 and NaOH were used to produce the simulant gel for temperature of $25^{\circ}C$ and $50^{\circ}C$. The amount of bubbles produced during mixing of simulant gel at $50^{\circ}C$ were higher than that of simulant gel at $25^{\circ}C$. After 24 hours, bubbles of simulant gel made at $50^{\circ}C$ disappeared rapidly with respect to the bubbles of gel made at $25^{\circ}C$. Bubbles from blender did show notable amount even after 24 hours. Among mixing type, it was found that the pitched paddle impeller was the best candidate for the production of simulant gel.

  • PDF

Simulation of scattering in PMMA for high-efficiency backlight unit (고효율 백라이트 유닛을 위한 PMMA에서의 산란전산모사)

  • 오영식;정주영;박준철;김경찬;하기룡;강신원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.134-135
    • /
    • 2000
  • LCD의 전력소모중 약 70%를 차지하는 부분이 백라이트 유닛이다. 전세계적으로 저전력, 고화질, 대면적의 LCD 디스플레이를 개발하기 위한 연구가 활발히 진행중이다. 주로 백라이트 유닛을 구성하는 입사광학계와 도광체 및 프리즘 필름 등을 기존 제작공정 내에서 개선하는 것에 연구 개발의 초점이 맞추어져 있다. 본 연구는 기존의 개선 방법에서 벗어나 도광판의 형태와 산란입자의 크기에 따른 산란정도를 조절하여 기존의 도광판보다 더 나은 산란효율을 얻고자 한다. 이를 위해 투명도와 경도가 우수한 PMMA(polymethyl methacrylate)에 다양한 산란자를 투입하여 도광판을 제작한다. 도광판의 실제 제작 이전에 고효율 도광판속에서의 정확한 산란전산모사를 필수적으로 선행하여야 한다. 따라서 광산란 측정장치를 제작하여 산란자의 종류에 따른 원통형 도광체에서 측정한 산란강도와 산란전산모사에서의 결과를 비교 분석하여 저전력, 고화질, 대면적의 백라이트 유닛을 개발하기 위한 기초 자료로 사용하고자 한다. (중략)

  • PDF

특집:자연모사 그린테크놀로지 - 자연모사 바이오 접착 패치 개발

  • Kim, Jeong-Hun;Seo, Gap-Yang
    • 기계와재료
    • /
    • v.23 no.4
    • /
    • pp.16-25
    • /
    • 2011
  • 본고는 자연모사공학에서 출발하여, 자연계에 존재하는 건식 접착 성질을 이용하기 위한 방법으로서 게코도마뱀의 발바닥 섬모 구조를 모사하기 위한 방안들을 설명하고 그 응용분야를 전망한다. 도마뱀의 섬모 구조가 가지는 네 가지 특징들은 고분자 폴리머 재료와 나노 신장 기술, 2단계 UV 자외선 성형 기술, 전자빔 조사 등과 같은 기술을 통해 구조 및 기능의 모사가 가능하고 실제로 제작된 구조는 좋은 접착 특성을 나타냄을 알 수 있었다. 이를 토대로 다양한 섬모 구조에서의 접착 성능을 분석하고 실제 생활에서 바이오 패치로의 응용 가능성을 제시하였다.

  • PDF

Fabrication of a biomimetic hierarchical surface structure replicated from a lotus leaf (연꽃잎 모사를 통한 생체모방 계층적 표면 구조 제작)

  • Lee, Hyeong-Jin;Kim, Min-Seong;Kim, Geun-Hyeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.108-108
    • /
    • 2017
  • 다양한 생체 재료들을 이용한 마이크로 및 나노 크기의 표면 구조 모사는 조직공학에서 세포의 성장 및 분화에 영향을 미치는 것으로 알려져 있다. 특히, 마이크로-나노 구조가 공존하는 계층적 표면 구조는 골 아세포의 증식과 분화에 탁월하여 뼈 조직 재생에 응용되어 왔다. 기존에는 화학적 처리 기법을 이용하여 마이크로 표면 구조가 제작 되었으나 미세 거칠기 및 계층적 표면 구조의 제어가 어려웠다. 현재 이러한 문제점들을 극복하기 위해 플라즈마를 이용한 애칭 기법이 주로 이용되고 있으나 높은 온도 공정 환경에 의한 재료 선택의 한계점 및 오랜 공정 시간에 의한 플라즈마 처리 효율이 감소되어 원하는 표면구조 및 거칠기를 얻을 수 없다는 단점이 있다. 본 연구에서는 이러한 문제점들을 극복하기 위해 마이크로/나노 주조 기법 이용하여 생체적합성 합성고분자 poly(${\varepsilon}$-caprolactone) (PCL) 위에 연꽃잎 구조를 모사한 후 플라즈마 애칭 기법을 이용하여 마이크로-($3.01-3.07{\mu}m$)와 나노크기 ($97{\pm}16nm$)를 동시에 갖는 계층적 구조를 제작하였다. 제작된 구조의 효능을 관찰하기 위해 조골세포를 배양한 결과 평평한 PCL 구조보다 제작된 계층적 구조가 높은 세포성장률 (>2.9배)및 세포 분화도(>2.1배)를 보였다. 이러한 결과는 새로운 표면 공학적 모델로서 손상된 뼈 및 치아조직 재생을 위한 적합한 거칠기 및 표면적인 환경을 제공해 빠른 재생 능력과 더불어 치료기간의 단축을 가져 올 수 있을 것으로 사료된다.

  • PDF

우주환경모사용 대형열진공챔버 국산화 개발 및 유지

  • Lee, Sang-Hun;Mun, Gwi-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.69.1-69.1
    • /
    • 2015
  • 우주환경은 고진공 환경과 태양 복사열에 의한 고온 환경 및 극저온이 반복되는 가혹한 환경으로 특징지어지는데, 위성체는 지상에서 발사되어 우주궤도에 진입한 순간부터는 계속해서 우주환경에 노출된다. 위성체가 이러한 가혹한 우주환경에 노출될 경우 주요부품에 기능장애가 초래되기도 하며 이는 결국 임무의 실패로 이어지도 한다. 따라서 위성체는 지상에서 우주환경시험을 거쳐 기능 및 작동상태를 점검해야 하며, 이를 위해서는 우주환경을 모사 할 수 있는 우주환경 모사장비가 필요하다. 우주환경모사장비라함은 우주환경의 주특징인 고진공상태와 극저온 및 고온 환경을 모사할 수 있는 지상장비를 말하며, 통상 열진공챔버라고 불린다. 한국항공우주연구원에서는 위성의 부품레벨에서부터 대형위성시스템의 열진공시험 수행을 위한 다양한 진공챔버를 보유하고 있으며, 그 직경이 0.7 m인 소형에서부터 직경 9 m, 길이 10 m급의 대형열진공챔버에 이른다. 대형 챔버의 경우 고기능화에 따라 대형화 되어 가는 위성의 국산화 개발을 위하여 순수 국내 기술로 제작된 우주환경모사용 챔버이다. 본 대형열진공챔버의 제작 및 유지 현황에 대해 논의한다.

  • PDF

Ultrasonic Phantom Based on Plastic Material for Elastography (초음파 탄성 영상 평가를 위한 플라스틱 기반의 팬텀 개발)

  • Ahn, Dong-Ki;Joung, Mok-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.368-373
    • /
    • 2009
  • A human tissue mimicking phantom is constructed to assess the performance of a medical ultrasound elasticity imaging system. In a human body, the tumor or cancer is stiffer than its surrounding normal tissue. A technique fur imaging the elasticity of such a tissue is referred to as elastography. Homogeneous elasticity phantoms with differing Young's moduli are constructed using a plastic hardener and softener to simulate the mechanical characteristics of a diseased human tissue. The Young's modulus of the fabricated homogeneous phantom materials were measured from 11.1 to 79.6 kPa depending on the mixing ratio of the amount of the hardener to that of the softener. An ultrasound lesion mimicking phantom was made of these materials, and ultrasound elasticity imaging was performed on it. It is confirmed in this paper that the fabricated plastic-based elasticity phantom is useful in representing the elastic characteristics of a human tissue.

CMOS Inverter Delay Model Using the Triangle-shaped Waveform of Output Current (삼각형 모양의 출력 전류 모형을 이용한 CMOS 인버터 지연 모사)

  • Choi, Deuk-Sung
    • 전자공학회논문지 IE
    • /
    • v.48 no.3
    • /
    • pp.1-9
    • /
    • 2011
  • In this paper, we develop an analytical expression for the propagation delay of submicrometer CMOS inverter using the triangle-shaped waveform of output current and two fitting parameters. Our model shows that simulation results are well in accordance with HSPICE results. Maximum simulation errors of total inverter delay and jitter are below 0.6% and 2.8%, respectively. Comparing with previous researches, the new model has better fittering characteristics in the range of low operating voltage. We also have fabricated the inverters with ten chains and estimated inverter delay and jitter characteristics. The results show that the values of delay and jitter in the fabricated samples come close to the values of those in the new model.

Experimental Study of Machining Process of Polymer Mold for Fabrication of Three-Dimensional Hydrogel Scaffold (3 차원 하이드로젤 지지체 제작을 위한 고분자 몰드의 가공 특성에 대한 실험적 연구)

  • Lee, Pil-Ho;Lee, Sang Won;Kim, Daehoon;Kim, Si Hyeon;Sung, Jong Hwan;Chung, Haseung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.669-674
    • /
    • 2013
  • A three-dimensional hydrogel scaffold has been proposed for the effective production of biomimetic intestinal villi to reduce ethical and cost problems caused by animal testing in pharmaceutical development. This study explores an experimental approach to develop a new technique based on laser machining and microdrilling processes to produce a plastic mold for the fabrication of a three-dimensional hydrogel scaffold. For process optimization, both the laser machining and the microdrilling experiments are conducted by varying the experimental conditions, and structural characterization of the mold and intestinal villi were performed using SEM (scanning electron microscope) and OM (optical microscope) images. Polycarbonate (PC) was used as a candidate material. The experimental results show that intestinal villi can be fabricated by both laser and microdrilling machining processes.

Design and Manufacturing of Robotic Dolphin with Variable Stiffness Mechanism (가변강성 메커니즘을 적용한 로봇 돌고래 설계 및 제작)

  • Park, Yong-Jai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.103-110
    • /
    • 2020
  • Bio-inspired underwater robots have been studied to improve the dynamic performance of fins, such as swimming speed and efficiency, which is the most basic performance. Among them, bio-inspired soft robots with a compliant tail fin can have high degrees of freedom. On the other hand, to improve the driving efficiency of the compliant fins, the stiffness of the tail fin should be changed with the driving frequency. Therefore, a new type of variable stiffness mechanism has been developed and verified. This study, which was inspired by the anatomy of a real dolphin, assessed a process of designing and manufacturing a robotic dolphin with a variable stiffness mechanism. By mimicking the vertebrae of a dolphin, the variable stiffness driving part was manufactured using subtractive and additive manufacturing. A driving tendon was placed considering the location of the tendon in the actual dolphin, and the additional tendon was installed to change its stiffness. A robotic dolphin was designed and manufactured in a streamlined shape, and the swimming speed was measured by varying the stiffness. When the stiffness of the tail fin was varied at the same driving frequency, the swimming speed and thrust changed by approximately 1.24 and 1.5 times, respectively.