• 제목/요약/키워드: 디지털 인터페이스

Search Result 854, Processing Time 0.058 seconds

The development direction and Analysis on Graphic authoring tool according to Design work frame -Focused on Interface design- (디자인 업무 유형에 따른 그래픽 저작도구의 사용 현황과 발전 방향 -인터페이스 디자인 분야를 중심으로-)

  • Jung, Da-young;Kim, Seung-In
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.11
    • /
    • pp.233-240
    • /
    • 2017
  • In recent years, graphics authoring tools have evolved into a variety of formats in line with the rapidly changing digital design field. However, in the field of interface design, screen shape and size depending on the user's environment, it needs more flexible and scalable authoring tools. Along with the emergence of variety of new tools, work processes are also changing. This study investigates what kinds of graphic authoring tools are currently used by designers and compared the result to the case of overseas and examined the difference in the environment of graphic authoring tool. This study looked at criteria and satisfaction of designers choosing authoring tools and how the choice depends on the type of company we are working in and the type of project we are involved in. Research shows that the choice of authoring tools depends on the type and efficiency of the project. Based on this, a reference is provided to establish the standard and working environment for designers and companies to select graphic authoring tools and propose the future direction of graphic authoring tool environments.

Design and Implementation of Message Format and Server for Interworking EMR System and Gateway of Medical Devices (의료기기 통합 게이트웨이와 EMR 시스템간의 연동을 위한 메시지 규격 설계 및 서버 구현)

  • Im, Seokjin;Hwang, Hee-Joung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.6
    • /
    • pp.255-262
    • /
    • 2013
  • Medical Gateway(MG), that integrates medical devices with its unique data format in various hospital information systems, provides effectiveness in the cost of the management unlike existing systems that uses PC as a gateway to hospital information systems because MG enables to interface medical devices with itself. However, in spite of using MG for integrating medical devices, we need additional programs or systems to interwork with EMR system of each hospital in accordance with the configuration of DB. In this paper, we design and implement the format of medical information and server system for interworking MG with EMR system. The proposed system makes easy exchanging medical data between MG and EMR system. Thus, the proposed system can contribute to a national project to export abroad advanced hospital setup converged with IT.

Implementation of a Bluetooth-LE Based Wireless ECG/EMG/PPG Monitoring Circuit and System (블루투스-LE 기반 심전도/근전도/맥박 무선 모니터링 회로 및 시스템 구현)

  • Lee, Ukjun;Park, Hyeongyeol;Shin, Hyunchol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.261-268
    • /
    • 2014
  • This paper presents a electrocardiogram(ECG), electromyogram(EMG), and Photoplethysmography(PPG) signal wireless monitoring system based on Bluetooth Low Energy (BLE). ECG and EMG sensor interface analog front-end circuits are designed by using off-the-shelf parts. Texas Instruments(TI)'s CC2540DK is used for BLE-based communication. Two CC2540DK modules are used as Peripheral and Central nodes. In peripheral device, vital signals are acquired by the analog front-ends and fed to ADC for analog-to-digital conversion. The peripheral transmitts the data through the air to the central device. The central device receive the data and sends them to PC using UART. GUI is designed using Labview for displaying the acquired vital signals. The developed system can be used for future ubiquitous wireless healthcare system based on bluetooth 4.0.

Study on Wireless Control of a Board Robot Using an IMU sensor (IMU센서를 이용한 보드로봇의 무선제어 연구)

  • Ryu, Jaemyung;Kim, Dong Hun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.2
    • /
    • pp.186-192
    • /
    • 2014
  • This study presents the remote control of a board robot using an IMU sensor based on Bluetooth communication. The board robot is a kind of riding robot controlled throng wireless communication by a user. The user wears the proposed IMU sensor controller, and changes a direction of the robot by the angles of IMU sensor. Bluetooth is used for wireless communication between the board robot and its user. The IMU sensor in the remote controller is used for recognition of a number of actions, which are measured as analog signals. The user actions have five commands ('1'right '2'neutrality '3'left '4'operation '5'stop), which are transmitted from the user to the board robot through Bluetooth communication. Experimental results show that proposed IMU interface can effectively control the board robot.

TMCS : Tangible Media Control System (감각형 미디어 제어 시스템)

  • 오세진;장세이;우운택
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.10
    • /
    • pp.1356-1363
    • /
    • 2004
  • We propose Tangible Media Control System (TMCS), which allows users to manipulate media contents with physical objects in an intuitive way. Currently, most people access digital media contents by exploiting GUI. However, It provides limited manipulations of the media contents. The proposed system, instead of mouse and keyboard, adopts two types of tangible objects, i.e RFID-enabled object and tracker-embedded object. The TMCS enables users to easily access and control digital media contents with the tangible objects. In addition, it supports an interactive media controller which users can synthesize media contents and generate new media contents according to users' taste. It also offers personalized contents, which is suitable for users' preferences, by exploiting context such as user's profile and situational information. Therefore. the proposed system can be applied to various interactive applications such as multimedia education, entertainment and multimedia editor.

Study on Wireless Control of a Board Robot Using a Sensing Glove (장갑 센서를 이용한 보드로봇의 무선제어 연구)

  • Ryu, Jaemyung;Kim, Dong Hun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.4
    • /
    • pp.341-347
    • /
    • 2013
  • This study presents the remote control of a board robot using a Sensing glove based on Bluetooth communication. The board robot is a kind of riding robot controlled by an user. The user wears the proposed remote glove controller, and changes a direction of the robot by different kinds of finger actions. Bluetooth is used for wireless communication between the board robot and its user. CdS cell Sensors and a LED in the glove are used for recognition of a number of finger actions, which are measured as analog signals. The finger actions have five commands ('1'right '2'neutrality '3'left '4'operation '5'stop), which are transmitted from the user to the board robot through Bluetooth communication. Experimental results show that proposed a Sensing glove can effectively control the board robot.

Study on Integrated for Capacitive Pressure Sensor (용량성 압력센서의 집적화에 관한 연구)

  • 이윤희
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.1
    • /
    • pp.48-58
    • /
    • 1998
  • For the purpose of designing novel capacitance pressure sensor, several effects on sensitivity such as parasitic capacitance effects, temperature/thermal drift and leakage current have to be eleiminated. This paper proposed the experimental studies on frequency compensation method by electronic circuit technique, C-V converting method with switched capacitor and C-F converting method with schmitt trigger circuit. The third interface circuit by frequency compensation method is composed to eliminate the drift and leakage component by comparision sensing frequency with reference frequency. The signal transmission is realized by digital signal to minimize the influence of noise and high resolution is obtained by means of increasing the number of digital bits. In the fabricated high performance C-V interface, the offset voltage was not appeared, and in case of voltage source, 4.0V, feed back capacitance, 10㎊, the pressure, 0~10 ㎪, the sensitivity of C-V converter is 28 ㎷/㎪.V, the temperature drift characteristic, 0.051 %F.S./$^{\circ}C$ and C-F converter shows -6.6 Hz/pa, 0.078 %F.S./$^{\circ}C$ respectively, relatively good ones.

  • PDF

Design of Computer Vision Interface by Recognizing Hand Motion (손동작 인식에 의한 컴퓨터 비전 인터페이스 설계)

  • Yun, Jin-Hyun;Lee, Chong-Ho
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.3
    • /
    • pp.1-10
    • /
    • 2010
  • As various interfacing devices for computational machines are being developed, a new HCI method using hand motion input is introduced. This interface method is a vision-based approach using a single camera for detecting and tracking hand movements. In the previous researches, only a skin color is used for detecting and tracking hand location. However, in our design, skin color and shape information are collectively considered. Consequently, detection ability of a hand increased. we proposed primary orientation edge descriptor for getting an edge information. This method uses only one hand model. Therefore, we do not need training processing time. This system consists of a detecting part and a tracking part for efficient processing. In tracking part, the system is quite robust on the orientation of the hand. The system is applied to recognize a hand written number in script style using DNAC algorithm. Performance of the proposed algorithm reaches 82% recognition ratio in detecting hand region and 90% in recognizing a written number in script style.

An Implementation of Spirometry System Based Differential Pressure Method (차동 압력 방식을 이용한 호흡측정 시스템 구현)

  • 김요한;신창민;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.440-447
    • /
    • 2002
  • This paper considerated about exact flow volume calculation method from factors having an influence on measurement and introduced in anesthesia ventilator realized spirometry system. System used differential pressure sensing method with factors, that is temperature, pressure, gas density, humidity and mucus etc. System optimized for low power system for mobile system. System composed analog interface part, signal processing part, display part. Analog interface part have differential pressure flow sensor and defferential pressure sensor. Signal processing part have AVR processor for low power system display part use serial port (RS232, SPT). so it display at pc monitor or send to anesthesia ventilator. System is stable by linearizing 2th characteristics of flow-differential pressure, auto correction of sensor. Noise reduced by algorithm with analog filter and digital processing. Small, light, low power system is good at mobile system and applied to patient in emergency or mobile. and, System is useful at anesthesia ventilator by using flow sensor.

  • PDF

Design of Compensated Digital Interface Circuits for Capacitive Pressure Sensor (용량형 압력센서용 디지탈 보상 인터페이스 회로설계)

  • Lee, Youn-Hee;Sawada, Kouji;Seo, Hee-Don;Choi, Se-Gon
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.63-68
    • /
    • 1996
  • In order to implement the integrated capacitive pressure sensors, which contains integrated interface circuits to detect the electrical output signal, several main factors that have a bad effect on the characteristics of sensors must be improved, such as parasitic capacitance effects, temperature/thermal drift, and the leakage current of a readout circuitry. This paper describes the novel design of the dedicated CMOS readout circuitry that is consists of two capacitance to frequency converters and 4 bit digital logic compensating circuits. Dividing the oscillation frequency of a sensing sensor by that of reference sensor, this circuit is designed to eliminate the thermal/temperature drift and the effect of the leakage currents, and to access a digital signals to obtain a high signal-to-noise(S/N)ratio. Therefore, the resolution of this circuit can be increased by increasing the number of the digital bits. Digital compensated circuits of this circuits, except for the C-F converters, are fabricated on a FPGA chip, and fundamental performance of the circuits are evaluated.

  • PDF