• Title/Summary/Keyword: 두 화염

Search Result 88, Processing Time 0.019 seconds

Development of Current Limiting COS Fuse Link with Improved Overcurrent and Protection Coordination performance (과전류 차단과 보호협조 성능이 향상된 한류형 COS 퓨즈링크 개발)

  • Kim, Youn-Hyun;Kim, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.129-136
    • /
    • 2020
  • A Cut Out Switch (COS) is used for line protection and pole transformer protection in power systems. The COS used to protect the pole transformer is installed on the power side of the pole transformer to protect the electric equipment from fault currents. The COS is composed largely of a body and a fuse holder, and when the fault current is energized, the element of the fuse link in the fuse holder is melted to block the fault current. The arc generated when the COS fuse link is blown causes fire and noise, causing discomfort to residents in the surrounding area, and the arc flame can cause secondary damage to the peripheral device. In this study, a current-limiting COS fuse with improved overcurrent blocking performance rather than explosion type was developed to solve the arc and noise problems during COS operation. The overcurrent breaking performance of the current-limiting COS improves the reliability by developing a striker and COS fuse bracket. In addition, this study aimed to verify the performance of the developed current-limiting COS fuse through a test at an authorized institution.

Effects of Organic Salts Fortified with Seaweed Components on Blood Pressure, Serum Minerals, and Hematochemicals in Spontaneously Hypertensive and Normotensive Rats (해조성분 강화염이 본태성 고혈압쥐와 정상혈압쥐의 혈압, 혈청 중 미네랄 함량 및 생화학적 특성에 미치는 영향)

  • Kim, Young-Myoung;Byun, Jee-Young;Han, Chan-Kyu;Sung, Ki-Seung;Namgung, Bae
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.196-202
    • /
    • 2009
  • The effects of the salts fortified with seaweed functional components on blood pressure, serum minerals, and hematochemicals in spontaneously hypertensive rats (SHR/NCrj) and normotensive rats (WKY/NCrj) were investigated. SHR and WKY rats were assigned to four groups, with 8 and 6 rats in each group: laver salt (A), fucoidan+laver high salt (B), fucoidan + laver low salt (C) and refined salt as a control (D). The final blood pressure (BP) of SHR and WKY species in contrast with reference BP were low in groups A and C as compared with control group. In terms of serum mineral content, $Na^+$ levels were similar in SHR and WKY, but $K^+$ levels were higher in the group B in SHR. Serum triglyceride levels were lower in groups A and C, but the levels of HDL- and LDL- cholesterol were significantly higher and lower in group A than those of controls, respectively (p<0.05). These results demonstrated that the salts fortified with laver might suppress blood pressure in rats, and also may improve mineral and lipid metabolism.

Development of Helmholtz Solver for Thermo-Acoustic Instability within Combustion Devices (연소시스템의 열음향 불안정 예측을 위한 Helmholtz Solver 개발)

  • Kim, Seong-Ku;Choi, Hwan-Seok;Cha, Dong-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.5
    • /
    • pp.445-455
    • /
    • 2010
  • In order to effectively predict thermo-acoustic instability within real combustors of rocket engines and gas turbines, in the present study, the Helmholtz equation in conjunction with the time lag hypothesis is discretized by the finite element method on three-dimensional hybrid unstructured mesh. Numerical nonlinearity caused by the combustion response term is linearized by an iterative method, and the large-scale eigenvalue problem is solved by the Arnoldi method available in the ARPACK. As a consequence, the final solution of complex valued eigenfrequency and acoustic pressure field can be interpreted as resonant frequency, growth rate, and modal shape for acoustic modes of interest. The predictive capabilities of the present method have been validated against two academic problems with complex impedance boundary and premixed flame, as well as an ambient acoustic test for liquid rocket combustion chamber with/without baffle.

A Study on the Identification Technique and Prevention of Combustion Diffusion through ESS (Energy Storage System) Battery Fire Case (ESS (에너지 저장장치) 배터리 화재사례를 통한 감식기법 및 연소 확산방지에 관한 연구)

  • Lee, Jung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.383-391
    • /
    • 2020
  • Purpose: To identify internal self ignition and ignition caused by external flames in energy storage rooms, and to analyze the difference between ignition due to overheating and ignition caused by external heat sources. Method: membrane melting point measurement, battery external hydrothermal experiment, battery overcharge experiment, comparative analysis of electrode plate during combustion by overcharge and external heat, overcharge combustion characteristics, external hydrothermal fire combustion characteristics, 3.4 (electrode plate comparison) / 3.5 (overcharge) /3.6 (external sequence) analysis experiment. Result: Since the temperature difference was very different depending on the position of the sensor until the fire occurred, it is judged that two temperature sensors per module are not enough to prevent the fire through temperature control in advance. Conclusion: The short circuit acts as an ignition source and ignites the mixed gas, causing a gas explosion. The electrode breaks finely due to the explosion pressure, and the powder-like lithium oxide is sparked like a firecracker by the flame reaction.

The Effect of Radiative Heat Flux on Dynamic Extinction in Metalized Solid Propellants (복사열전달이 고체 추진제의 동적소화에 미치는 영향)

  • Jeong, Ho Geol;Lee, Chang Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.72-79
    • /
    • 2003
  • A numerical calculation was conducted to estimate and to elucidate the role of the radiative heat flux from metal particles(Al, $Al_2O_3$) on the dynamic extinction of solid propellant rocket where the rapid depressurization took place. Anon-linear flame modeling implemented by the residence time modeling for metalized propellant was adopted to evaluate conductive heat flux to the propellant surface. The radiative heat feed back was calculated with the aid of a modified comvustion-flow model as well. The calculation results with the propellant of AP:Al:CTPB=76:10:14 had revealed that the radiative heat flux is approximately 5~6% of total flux at the critical depressurization rate regardless of chamber geometry (open or confined chamber). It was also found that the dynamic extinction in open geometry could be predicted at the depressurization rate about 45% larger with radiative heat feedback than without radiation. Thus, it should be claimed that even a small amount of radiative flux 5~6% could produce a big error in predicting the critical depressurization rate of the metalized propellant combustion.

Study on Combustion Characteristics of Unielement Thrust Chambers with Various Injectors (다종의 동축 스월형 단일 분사기 연소 특성에 관한 실험적 연구)

  • Seonghyeon Seo;Lee, Kwang-Jin;Han, Yeoung-Min;Kim, Seung-Han;Kim, Jong-Gyu;Moon, Il-Yoon;Seol, Woo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.2
    • /
    • pp.85-94
    • /
    • 2004
  • Experimental study on combustion characteristics of double swirl coaxial injectors has been conducted for the assessment of critical injector design parameters. A reusable, unielement thrust chamber has been fabricated with a water-cooled copper nozzle. Two principal design parameters. a swirl angle and a recess length, have been investigated through hot firing tests for the understanding of their effects on high pressure combustion. Clearly, both parameters considerably affect the combustion efficiency, dynamics and hydraulic characteristics of an injector. Internal mixing of propellants in a recess region increases combustion efficiency along with the increase of a pressure drop required for flowing the same amount of mass flow rates. It is concluded that pressure buildup due to flame can be released by the increase of LOx flow axial momentum or the reduction of a recess length. Dynamic pressure measurements of the thrust chamber show varied dynamic behaviors depending on injector configurations.

Effects of the mold surface heating methods for the DVD stamper with nano pattern on the transcription of the injection molded parts using COC and PMMA plastics (나노패턴을 갖는 DVD용 스템퍼의 표면가열방식이 COC, PMMA 수지를 이용한 사출성형품의 전사성에 미치는 영향)

  • 김동학;유홍진;김태완
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.3
    • /
    • pp.218-222
    • /
    • 2004
  • We developed the stamper structured mold with moving core type with nano pattern. Among the factors affecting the quality of injection molding plastic parts, We studied the effects of moving core surface heating method on the transcription of injection molding plastic parts with nano structures. Moving core surface heating has been tested by three different methods. The first was conventional injection molding process without heating moving core surface, the second was halogen lamp radiation heating process and the last was MmSH process using gas flame. As a result of making injection molded parts by using thermoplastic amorphous resins such as COC, PMMA, MmSH method which is the most high temperature of moving core surface showed the best nano pattern transcription of the three methods, but the outcome of conventional injection molding process was not better than others.

  • PDF

Effect of Combined Treatment of Ultraviolet-C with Aqueous Chlorine Dioxide or Fumaric Acid on the Postharvest Quality of Strawberry Fruit "Flamengo" during Storage ("플라멩고" 딸기의 수확 후 Ultraviolet-C와 이산화염소수 또는 푸마르산 병합 처리에 따른 저장 중 품질에 미치는 영향)

  • Kim, Ju-Yeon;Kim, Hyun-Jin;Lim, Geum-Ok;Jang, Sung-Ae;Song, Kyung-Bin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.1
    • /
    • pp.138-145
    • /
    • 2010
  • The combined effect of 50 ppm aqueous chlorine dioxide ($ClO_2$) or 0.5% fumaric acid with $5 kJ/m^2$ ultraviolet-C (UV-C) on the postharvest quality of "Flamengo" strawberries was examined. After non-thermal treatment, the samples were stored at $4\pm1^{\circ}C$ for 12 days. The combined treatment of fumaric acid/UV-C reduced the initial populations of total aerobic bacteria and yeast and molds in the strawberries by 2.09 and 2.02 log CFU/g, respectively, compared to those of the control. In addition, after 12 days of storage the yeast and molds population in the combined treatment was 1.72 log CFU/g, compared to 5.10 log CFU/g for the control, resulting in a significant decrease of 3.38 log CFU/g. Postharvest treatments used in this study caused negligible changes in the color of the strawberries. Sensory evaluation results indicated that the combined postharvest treatment provided better sensory scores than did the control. In particular, the overall acceptability scores were higher for the combined treatment groups after 5 days of storage. These results suggest that combined treatment of either 50 ppm $ClO_2$ or 0.5% fumaric acid with $5 kJ/m^2$ UV-C can be useful for maintaining the quality of strawberries.

Mg-Al합금의 조성비율에 따른 발화온도특성

  • Han, U-Seop;Lee, Geun-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.77-77
    • /
    • 2013
  • 최근의 산업활동에서는 신규 원료 개발과 생산 효율성을 높이기 위하여 분체 공정이 증가하고 있는데, 미세 분진의 취급으로 분진운의 형성과 착화가 용이해지므로 분진폭발이나 화재 위험성이 증가하고 있다. 분진을 안전하게 사용하고 저장, 취급하기 위해서는 착화 전의 위험성 지표로서 최저발화온도(MIT ; Minimum Ignition Temperature)를 사전에 파악해 두는 것이 중요하다. 분진농도의 발화온도는 장치 내의 발화위험성이나 분진 취급 공정의 사고예방대책 관리를 위한 실용적 관점에서 중요하게 활용되는 폭발특성값이다. 또한 분진의 발화온도는 분진농도에 의존하며 농도변화에 따른 가장 낮은 온도를 MIT라고 한다. 본 연구에서는 화재폭발사고 빈도가 줄지 않고 있는 Mg 및 Mg-Al합금(60:40 wt%, 50:50 wt%, 40:60 wt%)을 대상으로 조성비율에 따른 최저발화온도를 실험적으로 조사하였다. Mg 및 Mg-Al(60:40 wt%), Mg-Al(50:50 wt%), Mg-Al(40:60 wt%) 시료의 평균입경은 142, 160, 151, $152{\mu}m$이다. MIT실험장치는 IEC 61241-2-1(Methods for Determining the Minimum Ignition Temperatures of Dust, 1994)에 준거하여 제작하여 사용하였다. 실험장치는 가열로, 분진운 시료홀더, 온도조절장치, 압축공기 제어장치 등으로 구성되어 있다. 구체적인 실험방법은 시험분진를 분진홀더에 장착하고 0.5 bar의 압축공기를 0.3 sec 동안 사용하여 일정 온도로 가열된 로의 내부로 분진운을 부유시킬 때에 분진운이 발화하여 가열로 하단부의 개방구에까지 화염이 전파하는지를 디지털비데오카메라로 기록, 평가하여 발화 유무를 판정하였다. Mg합금에 대한 MIT를 측정한 결과 $740^{\circ}C$가 얻어졌으며, Mg-Al(60:40 wt%)의 MIT는 $820^{\circ}C$로 조사되었다. 그러나 Mg-Al(50:50 wt%) 및 Mg-Al(40:60 wt%)에 대해서는 최대 가열로의 설정온도를 $890^{\circ}C$까지로 하여 농도를 변화시키면서 조사하였으나 발화가 일어나지 않았다. 문헌에 따르면 Mg입자 표면의 산화피막은 다공성으로 일정 온도에서 산화반응이 시간에 따라 직선적으로 증가하는데 반하여, Al의 산화피막은 보호 작용을 하여 일정 온도에서 산화반응속도가 표면과 내부의 농도 기울기에 의한 확산속도에 의존한다고 보고하고 있다. 본 연구결과를 토대로 Mg-Al합금의 발화특성을 고찰해 보면, Mg-Al합금에서 자기 전파성이 작은 Al성분의 증가는 착화지연이 증가하여 연소성이 감소하여 최저발화온도의 증가로 이어지는 것으로 추정되었다. 또한 발화온도는 주어진 조건의 온도장에서 분진이 존재하는 시간 길이에 따라 변화하므로, 발화온도를 실험적으로 측정하는 경우에는 측정장치나 방법에 따라 달라지므로 사업장의 현장에 발화온도를 적용하는 경우에는 장치 내의 분진의 존재시간을 고려할 필요가 있다.

  • PDF

Numerical Study of Flow Characteristics in a Solid Particle Incinerator for Various Design Parameters of Injectors (고체 입자 소각로에서 분사기의 설계 인자에 따른 유동 특성에 관한 수치해석적 연구)

  • Son, Jin Woo;Kim, Su Ho;Sohn, Chae Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1079-1089
    • /
    • 2013
  • The flow characteristics in a solid particle incinerator are investigated numerically for high burning rate of wastes. The studied incinerator employs both a swirl flow used in the furnace of powerplants and a design concept applied to a rocket combustor. As the first step, the non-reactive flow field is analyzed in the incinerator with primary and secondary injectors through which solid fuel and air are injected. The deflection angle of a primary injector, inclination angle of a secondary injector, and gap between the two types of injectors are selected as design parameters. The swirl number is adopted for evaluating the degree of swirl flow and estimated over wide ranges of three parameters. The swirl number increases with deflection angle, but it is affected little by inclination angle. Recirculation zones are formed near the injectors, and their size affects the swirl number. The swirl number decreases with the zonal size of recirculation. From the numerical results, the design points can be found with strong swirl flow.