• Title/Summary/Keyword: 동 튜브

Search Result 173, Processing Time 0.026 seconds

Analysis of Online Educational Videos for Patients with Radiation Therapy (방사선치료 환자를 위한 온라인 교육 동영상 분석)

  • Kim, Dae-Gun;Jeong, Jae-Hong
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.31-39
    • /
    • 2022
  • This study aimed to analyze educational understanding and satisfaction by survey including for the online educational videos by used online platform (YouTube) which provide resolve patient's questions, require attention and treatment information for a patient with radiation therapy. Video viewing analysis was used by YouTube studio. The survey was analyzed general properties (age, academic ability, disease, and watched of no watched videos) and educational understanding and satisfaction for two groups as no watched and watched patients. The views number was 60% at the female higher than 40% at the male. Based on the standard viewing time (hours), the non-subscription rate was 86.7%. The device type mostly used the mobile phone (82.8%). The viewership of educational videos was lower as the age increased and the academic ability decreased in the survey. The educational understanding increased by 22% at watched group as 4.15 point from at no watched group as 3.4 point (p<0.001), and the educational satisfaction increased by 15.8% at watched group as 4.25 point from at no watched group as 3.67 point (p<0.01). The correlation of understanding (r=0.761) and satisfaction (r=0.767) was high for both no watched and watched groups (p<0.01). The online educational videos increased educational understanding and satisfaction for the patient with radiation therapy. Our study could be used references data for improving the quality of medical services.

The Design and Application of Vibrator Type(AM) Combination Apparatus for Improving Police Equipment for Fugitive Prevention (도주방지용 경찰장구의 기능개선을 위한 진동자 방식(AM) 결속장치 설계 및 응용)

  • Choi, Ki-Nam;Lee, Seon-Jeh
    • Convergence Security Journal
    • /
    • v.11 no.2
    • /
    • pp.13-24
    • /
    • 2011
  • Policemen judge the situations rationally and use their equipment such as handcuffs and rope within the purview, finding them needed to arrest criminals in the act who commit crimes which conforms to death penalty, life imprisonment or long imprisonment for over 3 years in accordance with Clause 10-2, Article 1 of the Police Mandate Law and prevent fleeing from them, defend their and others' lives and bodies, or if there are probable causes to be recognized that using equipment is necessary to restrain the interference with government officials in the execution of their duties. However, as the cases which the criminals run away in handcuffs or with both hands tied occur, it results in the waste of police force, distrust and enormous trouble in the pursuit of their duties. Therefore, if the way to perceive fleeing of criminals who have already worn the police equipment by some simple assistive devices without developing other new equipment, it will be very effective for police duties. This study is about the combination apparatus for fugitive prevention attached to the existing handcuffs and rope whose alert sounds let the staffs working inside the office perceive the fleeing of wanted criminals and examined suspects who wear the handcuffs or are tied up with rope, providing that they go through the exit where a transmitter and a receiver were set. The combination apparatus for fugitive prevention which the study introduces contains the connecting parts which connect a flexible tube(cognition tags inside of the tube) of connector equipped with the police equipment with the ends of the tube and the part where these two meet and which connect them inside of the tube. The connecting parts are easy to be attached to the police equipment such as handcuffs and rope, but hard to be dismantled by the people tied up with the equipment. It enables watchers to perceive the fleeing of wanted criminals and examined suspects who wear the handcuffs or are tied up with rope, providing that they go through the exit where a transmitter and a receiver were set. Plus, if it is combined together with the portable receiver, it can be installed on the patrol cars and easily adopted to supervise illegally accessing of evidences. It is also avaliable to be adjunctively utilized for the handcuffs provided and the cost is so reasonable. Owing to its snap-on way to the cuffs, it can clear up any invasion of privacy and it can not be used as a self-injury tool because of the soft tube. Using AM Tag minimizes the lack of malfunction.

Development of the Small Scale Testbed for Running Dynamic Characteristics Analysis of the Capsule Train (캡슐트레인 주행 동특성 분석을 위한 축소 시험장치의 개발)

  • Lee, Jin-Ho;You, Won-Hee;Lee, Kwansup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.643-651
    • /
    • 2020
  • A capsule train runs inside a sub-vacuum tube and can reach very high speed due to the low air resistance. A capsule train uses a superconducting electrodynamic suspension (SC-EDS) method for levitation, which allows for a large levitation gap and does not require gap control. However, SC-EDS has inherent characteristics such as the large gap variation and a small damping effect in the levitation force, which can degrade the running stability and ride comfort. To overcome this, a stability improvement device should be designed and applied based on dynamic analysis. In this study, a 1/10 small-scale testbed was developed to replicate the dynamic characteristics of a capsule train and investigate the performance of stability improvement devices. The testbed is composed of a 6-degree-of-freedom Stewart platform for the realization of bogie motion, a secondary suspension with a running stabilization device, and a carbody. Based on the dynamic similarity law proposed by Jaschinski, the small-scale testbed was manufactured, and a bogie motion algorithm was applied with the consideration of guideway irregularity and levitation stiffness. The experimental results from the testbed were compared with simulation results to investigate the performance of the testbed.

Consideration for the Repeaterless Transmission in Long Distance Optical Submarine Cable System (장거리 해저 무중계 전송기술 연구)

  • Park, Hong-Tae;Kim, Chun-Suk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.2 no.1
    • /
    • pp.40-45
    • /
    • 2007
  • The repeaterless system can be designed by applying EDFA technology in receiver, transmitter and optical cable in the case of connecting several hundred km from coast to coast, between continents or islands. Because of no repeater the repeaterless system do not need power system to feed laser diode in repeater for signal amplification and cooper tuber in submarine cable. So we can be configured more reliable and economical compared to repeater system. But lower loss optical fiber must be used to get enough signal amplitude without the amplification of repeater. This report consider long distance optical repeaterless system by reflecting the limitation factor of optical amplification.

  • PDF

A Study of Borehole Thermal Behavior with 1-Dimensional Model;Field Test Analysis included (1차원 모델에 의한 보어홀 열거동 해석 및 현지측정)

  • Kim, Dae-Ki;Woo, Joung-Son;Ro, Jeong-Geun;Lee, Se-Kyoun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.550-554
    • /
    • 2007
  • A one-dimensional heat transfer model coupled with parameter estimation is developed in this study to predict the effective thermal conductivities of soil formation and borehole resistances from in situ field test data. In this application a new method of using initial ignoring time(IIT) obtained from error estimation is tried and turned out to be successful in determining soil thermal conductivities. The validity of this model is accomplished through comparison of the predicted temperature profiles of the model with the data from laboratory scale experimental setting. Eleven test boreholes were constructed in Ochang, Chungcheong Buk Do, and thermal response test was carried out with each borehole. The results of the in situ tests were analyzed with our 1-D numerical model and compared with the results of line source method. The comparison shows that the thermal properties from line source method is a little lower (${\sim}95%$)than those from numerical method. The reason of such result seems to be the lower thermal conductivity of grout material, which is not counted in line source method.

  • PDF

Vibration Stability Analysis of Furnace System in Supercritical Boiler (초임계압 보일러 연소로의 진동안정성 평가기법 연구)

  • Kwon, Hyuk-Min;Cho, Chi-Hoon;Kim, Heui-Won;Joo, Won-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.13-15
    • /
    • 2014
  • 최근 경제적인 연비와 효율적인 가동성, 배기가스 감소의 이유로 초임계압 보일러가 각광받고 있다. 하지만 보일러 연소로는 용접된 튜브로 구성되어 있기 때문에 연소 시 내부압력에 의해 발생되는 진동에 취약하여 이에 대한 진동안정성 평가가 필요하다. 본 논문에서는 CFD 기법을 기반으로 수행한 변동압력 해석과 단순화한 모델을 이용한 진동해석을 통하여 보일러 운전 시의 진동안정성 평가를 수행하였다. 변동압력해석은 정상상태 CFD 해석을 수행하고, 이를 이용한 음향모드 해석과 비정상상태 CFD 해석에서 변동압력을 추출하고, 음향모드 해석결과와 주파수 성분을 비교하여 검증하였으며 이를 진동해석 모델에 기진력으로 적용하여 보일러 연소로의 진동해석을 수행하였다. 진동해석 모델은 동특성을 고려한 등가물성치를 이용하여 연소로의 복잡한 구조를 단순화하였으며 buckstay 등의 방진구조를 구현하여 보일러의 진동안정성을 평가하는 기법을 정립하였다. 해석결과, 보일러 운전조건에서 비정상상태 CFD 해석을 통해 구한 변동압력과 진동해석을 통해 얻은 가속도 응답은 안정적 수준인 것으로 확인하였다. 이는 향후 유사한 보일러 안정성 평가에 적용이 가능하고, buckstay 등 보일러의 방진 구조 설계 및 평가에도 적용할 수 있음을 확인할 수 있었다.

  • PDF

A Parametric Study on the Glass Transition and Mechanical Properties of CNT Based Nanocomposites Using Molecular Dynamics Simulation (분자동역학 전산모사를 이용한 나노튜브 강화 복합재료의 유리전이와 기계적 물성에 관한 파라메트릭 연구)

  • Yang, Seung-Hwa;Cho, Maeng-Hyo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.421-426
    • /
    • 2007
  • A parametric study to investigate the effects of composition variables on the glass transition and mechanical properties of CNT-based nanocomposites was performed using molecular dynamics simulations. In this study, matrix chain length and CNT length were chosen as the candidate characteristic parameters. In order to understand the effect of both parameters in detail, three sample sets having different chain lengths with the same CNT configuration and two sample sets having different CNT lengths with same chain length were prepared. Other parameters such as volume fraction and density were fixed to enable rigorous comparisons. Amorphous polyethylene is used as matrix polymer and (10,0) zigzag CNT is embedded into the matrix to reinforce polymer matrix. As a result, longer polymer chain length of matrix solely increased glass transition temperature but no reinforcing enhancement was observed. CNT length showed similar increase with little enhancement of elastic modulus. In addition to this, nanocomposites showed temperature-dependent elastic modulus jump passing thorough the glass transition region agrees well with experimental results.

  • PDF

Validity of Inter-Particle Models for the Mass-Transfer Kinetics of a Fin-Tube-Type Adsorption Bed (핀-튜브형 흡착탑 해석시 입자간 물질전달 모델의 타당성 검증)

  • Ahn, Sang Hyeok;Hong, Sang Woo;Kwon, Oh Kyung;Chung, Jae Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.12
    • /
    • pp.660-667
    • /
    • 2013
  • This study presents a numerical investigation of the heat and mass transfer kinetics of a fin-tube-type adsorption bed using a two-dimensional numerical model with silica-gel and water as the adsorbent and refrigerant pair. The performance is strongly affected by the heat and mass transfer in the adsorption bed, but the details of the mass transfer kinetics remain unclear. The validity of inter-particle models used to simulate mass-transfer kinetics were examined, such as a constant pressure model and non-constant pressure model, and the valid ranges of the diffusion ratio for each model are proposed. The COP and SCP have been numerically calculated as the performance indexes according to the diffusion ratio. The constant pressure model, which is commonly used in previous research, was found to be valid only in a limited range of diffusion ratio.

Numerical Analysis of the Heat and Mass Transfer in a Fin Tube Type Adsorber (핀튜브형 흡착탑에서 열 및 물질전달 수치해석)

  • Kwon, Oh Kyung;Chung, Jae Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.457-463
    • /
    • 2013
  • Nowadays, adsorption chillers have been receiving considerable attention, as they are energy saving and environmentally benign systems. A fin tube type heat exchanger in which adsorption/desorption takes place is required with more compact size. The adsorption chiller is expected to have high energy efficiency in utilizing the waste heat exhausted from a process. The objectives of this paper are to scrutinize the effect of design parameters on the adsorption performance, especially the fin pitch of the fin tube, and to develop an optimal design fin tube heat exchanger in a silica gel/water adsorption chiller. From the numerical results, the fin pitch of 2.5 mm shows the highest adsorption rate, compared to other fin pitches, such as 5 mm, 7.5 mm and 10mm. Also, the adsorption rate is affected by the cooling water and hot water temperature.

Reliability evaluation of periodontal disease oral health information on YouTube (동영상 공유 플랫폼에서 치주질환 구강건강정보의 신뢰도 평가)

  • Ji-Hyun Kim;Sun-Hee Hwang;Min-Young Kim
    • Journal of Korean society of Dental Hygiene
    • /
    • v.23 no.6
    • /
    • pp.423-429
    • /
    • 2023
  • Objectives: The study aimed to assess the form, reliability, and quality of information related to periodontal diseases shared on YouTube. Methods: On october 23, 2023, we conducted searches on YouTube using four keywords related to periodontal diseases. The searches retrieved a total of 394 videos from the first five pages for each keyword. Of these, 151 were included in the analysis. Videos were categorized based on the source and usefulness of the information, and their reliability and quality were assessed. Results: Analysis of the information sources revealed that medical websites or TV channels (45.7%) were the most prevalent, whereas commercial websites (2.0%) were the least prevalent. Videos uploaded by physician or hospitals (3.08±0.48) and medical websites or TV channels (3.01±0.94) demonstrated higher reliability. Videos categorized as having good and excellent quality were predominantly from physician or hospital sources (88.2%). Useful information related to periodontal diseases was available in 85.4% of videos, with physician or hospital sources contributing the highest proportion of useful information (52.7%). Conclusions: Videos from physician or hospital sources provide high-quality useful and reliable information. To ensure the provision of more useful and accurate information, the involvement and interest of experts are deemed essential.