• Title/Summary/Keyword: 동결융해 시험

Search Result 188, Processing Time 0.022 seconds

A Durability Assessment on Complex Deterioration of Concrete with Ground Granulated Blast-Furnace Slag Replacement (복합열화 환경하에서의 고로슬래그미분말 사용 콘크리트의 내구성능 평가)

  • Lee, Seung-Hoon;Kim, Hyung-Doo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.2
    • /
    • pp.171-175
    • /
    • 2010
  • This paper presents the experimental results of frost durability characteristics including freezing-thawing and de-icing salt scaling of the concrete for gutter of the road and marine structure. Mixtures were proportioned with the three level of water-binder ratio(W/B) and three binder compositions corresponding to Type I cement with 0%, 30% and 50% GGBS(Ground granulated blast furnace slag) replacement. Also, two different solutions of calcium chloride were used to evaluate their effect on the frost durability resistance. Specially, in case of complex of freezing and thawing with salt and carbonation, the deterioration of concrete surface is evaluated. Test results showed that the BFS30 and BFS50 mixture exhibited higher durability and lower mass loss values than those made with OPC mix and the use of GGBS can be used effectively in terms of economy and frost durability of the concrete to be in complex deterioration. Therefore, the resistance to complex deterioration with freezing-thawing was strongly influenced by the strength and the type of cement.

A Study on Freezing and Trawing Resistance of Concrete with the Ratio of Ground Granulated Blast-Furnace Slag Replacement (고로슬로그 미분말의 치환율에 따른 콘크리트의 동결융해 저항성에 관한 연구)

  • 최세규;김생빈
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.5
    • /
    • pp.149-155
    • /
    • 1997
  • 고로슬래그 미분말을 사용한 콘크리트\ulcorner 수화속도가 느려 어린 재령시 동해의 영향을받기 쉽다. 본 연구에서는 고로슬래그 미분말을 사용한 콘크리트의 동결융해 저항성을 알아보기 위해 고로슬래그 미분말의 치환율과 물-결합재비를 변화시켜 제조한 콘크리트에 대해 동결융해시험을 실시하였다. 또한 동일한 치환율, 물-결합재비의 콘크리트에 AE제를 첨가시켜 동결융해 저항성의 개선효과를 알아보았다. 시험결과 고로슬래그 미분말의 치환율이 증가할수록 동결융해 저항성은 작게 나왔다. 또한 non-AE 콘크리트의 경우 물-결합재비가 51%, 45%일 때 내구성지수는 각각 2.4%, 40.0%이하로 매우 나쁘게 나타났으나, AE콘크리트의 경우 물 -결합재비가 45%와 51%인 콘크리트의 내구성지수는 각각 90.2% 80.9%이상으로 동결융해 저항성이 매우 우수하게 나타났다.

Evaluation of Freeze-Thaw Effect on the Modulus of Subgrade Soils from Impact Resonance Test (충격공진시험을 이용한 동결.융해에 따른 노상토의 탄성계수 평가)

  • Lee, Jae-Hoan;Kweon, Gi-Chul
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.71-77
    • /
    • 2010
  • Anti-freezing layer does not used in case of non frost heaving in subgrade soils. In this case, the modulus of subgrade soils were varied with freezing and thaw cycles under non frost heaving. That effect should be properly considered in pavement design. Impact resonance test that is nondestructive testing method was used for continuously determining the modulus of subgrade soils during freezing and thaw cycle. The modulus of subgrade soils was identical with freezing and thaw cycles under closed freezing and thaw system which is no water supplement into specimen during testing. There was also no difference in the modulus of subgrade soil between before and after freezing-thaw cycles for all specimens with different water content and density. That is thaw-weakening of subgrade soils do not occur under closed freezing and thaw system. The moduli at freezing conditions are varied with water content and density, but it can be ignored in practical design sense.

Estimation of Weathering Characteristics of Sandstone and Andesite by Freeze-Thaw Test (동결융해시험에 의한 사암 및 안산암의 풍화특성 평가)

  • Kang, Seong-Seong;Kim, Jong-In;Obara, Yuzo;Hirata, Atsuo
    • Tunnel and Underground Space
    • /
    • v.21 no.2
    • /
    • pp.145-150
    • /
    • 2011
  • Variations of physical properties such as weight loss rate, wave velocity and uniaxial compressive strength after performing freeze-thaw cyclic test were measured in order to define weathering characteristics of sandstone and andesite. Weight change in specimens of the two rocks decreased with increasing the repetition number of freeze-thaw cyclic test. In particular, weight loss of andesite specimens was very irregular. P-wave velocity of sandstone specimens decreased more than 5%. On the other hand, P-wave velocity of andesite specimens do not vary up to 500 cycles and decreased more than 5% after 1000 cycles. This implies that the sandstone are easily weakened and loosened by weathering processes, while the andesite are relatively strong. In addition, the wave velocity changes of the andesite specimens coincident with the weight change. Uniaxial compressive strengths of the sandstone specimens slightly decreased at the early stage of the freezing-thawing cyclic test, then tended to be irregular after 64 cycles. In conclusion, the rock specimens showed smaller weight loss, less had lower strength reduction rate.

Evaluation of Tension Behavior in FRP Hybrid Bar Affected by UV Exposure and Freezing/Thawing Tests (UV 폭로 및 동결융해 시험을 거친 FRP Hybrid Bar의 인장거동 평가)

  • Yoon, Yong-Sik;Park, Jae-Sung;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.130-136
    • /
    • 2017
  • The present work is for an evaluation of tension behavior and surface deterioration of FRP Hybrid Bar due to UV exposure and freezing/thawing(F/T) actions. For the work, FRP Hybrid Bar is subjected to UV exposure test, then F/T test is performed successively to 180 cycles. In FRP Hybrid Bar, no significant surface deterioration is evaluated after UV exposure. Tension hardening performance, a unique engineering advantage of FRP Hybrid Bar, is still maintained after F/T test. The performance in FRP Hybrid Bar exposed to UV is still effective. FRP Hybrid Bar exposed to UV have almost similar tension behavior of FRP Hybrid Bar without UV exposure. Although F/T cycles increase to 180, steel rebar, FRP Hybrid Bar, and FRP Hybrid Bar exposed to UV show no significant changes in tension behavior. In the work, UV exposure and F/T actions are evaluated to have little negative effect on surface deterioration and tensile performance in FRP Hybrid Bar, however spalling of silica coating due to impact should be considered since it affects bonding strength to outer concrete.

Effect of Moisture and Freeze-Thaw on Mechanical Properties of CRM Asphalt Mexture (폐타이어 재활용 아스팔트 혼합물의 기계적 성질에 대한 습윤과 동결 융해의 영향)

  • 김낙석;조기주
    • Resources Recycling
    • /
    • v.9 no.3
    • /
    • pp.37-45
    • /
    • 2000
  • This paper presents the experimental test results on moisture and freeze-thaw resistance of hot mix crumb rubber modified (CRM) asphalt concrete mixture. To compare the differences in mechanical properties of conventional and CRM asphalt concretes, various tests were conducted under different moisture conditions and freeze-thaw cycles. Marshall mix design was also performed to determine the optimum asphalt contents for the both asphalt concrete mixtures. Test results revealed that the moisture and freeze-thaw resistance of CRM asphalt mixture was superior to the conventional asphalt concrete. As a result, it is considered that the utilization of waste tires in asphalt pavements has the potential of minimizing the damage due to the moisture and freeze-thaw.

  • PDF

Evaluation of Stripping and Rutting Properties of CRM Modified Asphalt Mixtures (CRM 개질아스팔트 혼합물의 소성변형 및 박리저항 특성)

  • Doh, Young-S.;Park, Tae-W.;Kim, Hyun-H.;Kim, Kwang-W.
    • International Journal of Highway Engineering
    • /
    • v.9 no.4
    • /
    • pp.149-158
    • /
    • 2007
  • Evaluation of the asphalt mixture modified with crumb rubber modifier(CRM) was performed to estimate possibility of using it as a paying material. OACs(optimum asphalt content) of CRM modified asphalt mixtures by dry process and wet process were determined by Marshall mix design and Wheel tracking test and moisture susceptibility test by freezing and thawing were carried out with CRM modified asphalt mixtures at OACs. The results from these tests, resistance of permanent deformation of CRM modified asphalt mixtures were superior to one of AP-5 while showing very low resistance of moisture sensitivity by freezing and thawing. This means that CRM modified asphalt mixtures are very sensitive to freezing and thawing. However, CRM modified asphalt mixture with anti-stripping material showed high improvement to resistance of moisture susceptibility by freezing and thawing. Therefore, it is recommended that when CRM mixtures were used in domestic, CRM modified asphalt mixtures should be with prevention against freezing and thawing resistance by moisture susceptibility.

  • PDF

Evaluation of Bond Strength in FRP Hybrid Bar Affected by Freezing/thawing Test and UV Rays (동결융해 및 UV 폭로시험을 거친 FRP Hybrid Bar의 인발거동특성 평가)

  • Park, Jae-Sung;Yoon, Yong-Sik;Park, Ki-Tae;Kwon, Sung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.1
    • /
    • pp.53-58
    • /
    • 2017
  • FRP Hybrid Bar, composed of an embedded steel and the coated composites with epoxy and glass fiber, is an effective construction material with tension-hardening performance and lightweight. The epoxy exposed to UV(Ultra Violet Rays) and FT(Freezing and Thawing) action easily shows a surface deterioration, which can cause degradation of bonding strength between inside-steel and outside-concrete. In the present work, surface inspection for 3 different samples of normal steel, FRP Hybrid Bar before UV, and FRP Hybrid Bar after UV test was performed, then concrete samples with 3 reinforcement types were prepared for accelerated FT test. Through visual inspection on 3 typed reinforcement, no significant deterioration like chalking was evaluated. The results from FT test to 120 and 180 cycles showed FRP Hybrid Bar exposed to UV test has higher bonding strength than normal steel by 106.3% due to enlarged bond area by silica coating. The 3 cases showed a similar bond strength tendency with increasing FT cycles, however a relatively big deviations of bond strength were evaluated in FRP Hybrid Bar after UV test due to loss of silica coating.

Compressive Strength and Durability Evaluation by Freezing and Thawing Test of Repaired Reinforced Concrete Columns (보수보강을 실시한 철근콘크리트 기둥의 동결융해시험을 통한 압축강도 및 내구성 평가)

  • Lee, Chang-Hyun;Eo, Seok-Hong
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.12
    • /
    • pp.529-536
    • /
    • 2020
  • This paper presents experimental investigations about compressive strength and durability of reinforced concrete compressive members repaired using ductile fiber reinforced cementitious composite (DFRCC) and carbon fiber sheet through freezing and thawing test. Total 24 RC specimens of 100x100x400mm size were tested by compressive strength test and freezing and thawing test by KS F 2456. The specimens were reinforced using 4D10 steels and repaired on 4 sides expect on top cycle. Test results showed that the specimens repaired using fiber carbon sheet revealed about 5% higher values of the compressive strength compared than the cases of DFRCC motar. On the other hand, the resurts did not showed meaningful differences in the aspect of durability. For further research, considerations of the steel interference effect and real old specimens such as taken from real deteriorated structures are needed to be tested after repairing with DFRCC and carbon fiber sheet.

Effects of Micropores on the Freezing-Thawing Resistance of High Volume Slag Concrete (슬래그를 다량 치환한 콘크리트의 동결융해 저항성능에 미치는 미세공극의 영향)

  • Kim, Rae-Hwan;Kim, Gyu-Yong;Lee, Bo-Kyeong;Shin, Kyoung-Su;Song, Gwon-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.67-74
    • /
    • 2015
  • In this study, effects of micropores on the freezing-thawing resistance of high volume slag concrete are reviewed. Concrete was made with slag which contains the ground granulated blast furnace slag(GGBS) and the pig iron preliminary treatment slag(PS) by replacing 0, 40, 70 %, then compressive strength, freezing-thawing resistance, micropores were reviewed. Also, specified design strength, target air contents were set. Deterioration was induced by using 14-day-age specimen which has low compressive strength for evaluating deterioration by freeze-thawing action. As results of the experiment, despite of specified design strength which has been set similarly and ensured target air contents, the pore size distribution of the concrete showed different results. Micropores in GGBS70 specimen have small amount of water which is likely to freeze because there is small amount of pore volume of 10~100 nm size at 0 cycle which has not been influenced by freezing-thawing. For these reasons, it was confirmed that the freezing-thawing resistance performance of GGBS70 is significantly superior than other specimens because relatively small expansion pressure is generated compared to the other specimens.