• Title/Summary/Keyword: 도플러 속도

Search Result 294, Processing Time 0.028 seconds

A Method for Non-invasive Diagnosis of bone by Measuring Phase Velocity (비침투적인 생체 경조직의 음향진단을 위한 기초실험)

  • Park, Mu-Hun
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.91-97
    • /
    • 1999
  • We propose a new method for measuring the frequency characteristics of phase velocity along a bone for bending vibration modes to diagnose its mechanical characteristics. By introducing a simple model of a distributed-constant-network, the phase velocity is determined for each frequency from the spatial distribution of velocity along a radius bone surface which is measured by the ultrasonic Doppler method.

  • PDF

Maximum exercise in 20 men Common carotid artery blood flow velocity impact (20대 남성에서 최대운동이 뇌로가는 혈관인 총경동맥 혈류 속도에 미치는 영향)

  • Kim, Ji-Won
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.5-12
    • /
    • 2009
  • Arterial blood from the heart chonggyeong passed directly to the cerebral arteries and the blood circulation is important, especially in arteries that prevent blood flow there are several variables. Among the variables the average flow velocity, pulse index, and blood flow resistance and which variables, double maekbakjisuna systolic and diastolic blood flow resistance index at the maximum rate and blood pressure associated with this because they are important variables, The change of variables such as speed noehyeolryu There are observations about the non-invasive ultrasound measurements using Doppler noehyeolryu uses. Up to 20 men in the exercise of noeroganeun hyeolryuin chonggyeong arteries to increase blood flow rates can be found.

  • PDF

Coherent Pulse Train Based Velocity Estimation and Compensation for High Resolution Range Profile of Moving Target in Stepped Frequency Radar (계단 주파수 레이더에서 이동표적의 고해상도 거리 추정을 위한 코히어런트 펄스열 기반의 속도 추정 및 보상)

  • Sim, Jae-Hun;Bae, Keun-Sung
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.309-315
    • /
    • 2018
  • A Stepped Frequency Radar(SFR) is a method of achieving high range resolution by gradually increasing the frequency of a transmitted pulse to create a wide synthetic bandwidth. However, in the case of moving target, accurate range estimation can not be performed due to the range-Doppler coupling phenomenon, so it is necessary to compensate through accurate velocity estimation. In this paper, we propose a stepped frequency radar waveform with a Coherent Pulse Train(CPT), velocity estimation results according to parameters using this method and VMD(Velocity Measurement Data) were compared and analyzed by numerical simulations.

Flow Velocity of Left Renal Vein in Children with Asymptomatic Hematuria or Proteinuria (무증상 혈뇨 또는 단백뇨 소아의 좌신정맥 혈류 속도)

  • Rhie Young-Jun;Hwang You-Sik;Kim, Myung-Joon;Lee Jae-Seung
    • Childhood Kidney Diseases
    • /
    • v.9 no.1
    • /
    • pp.15-20
    • /
    • 2005
  • Purpose : Nutcracker syndrome must be considered when hematuria or proteinuria occurs in a healthy child. The purpose of this study is to investigate the prevalence of nutcracker syndrome among children with asymptomatic hematuria or proteinuria, and to obtain the ratios of the peak velocity of the left renal vein between the aortomesenteric portion and the hilar portion in children with asymptomatic hematuna or protelnuria in which nutcracker syndrome was excluded and to observe whether the ratios are affected by sex, age or urinalysis findings. Methods : Using Doppler ultrasonography, we measured the flow velocity and obtained the peak velocity ratios of the left renal vein at the aortornesenteric portion and at the hilar Portion of the left kidney in children with asymptomatic hematuria or proteinuria who visited the Division of Pediatric Nephrology, Severance Hospital from May 2001 to March 2004. Results : Of 304 children with asymptomatic hematuna or proteinuria, 107 children(35.2%) were diagnosed with nutcracker syndrome. For 197 children with asymptomatic hematuria or proteinuria excluding nutcracker syndrome, the mean ratio of the peak velocity was 2.54 $\pm$0.73, which was not affected by sex, age or urinalysis findings. Conclusion : Nutcracker syndrome was the major cause of asymptomatic hematuria or proteinurla In children, comprising 35% of all cases. Doppler ultrasonography was helpful in the screening of nutcracker syndrome and prevention of its complications. For children with asymptomatic hematuria or proteinuria excluding nutcracker syndrome, the peak velocity ratio of the left renal vein did not differ from that of normal children and was not affected by sex, age or urinalysis findings. (J Korean Soc Pediatr Nephrol 2005;9:15-20)

  • PDF

A Quick-and-dirty Method for Detection of Ground Moving Targets in Single-Channel SAR Single-Look Complex (SLC) Images by Differentiation (미분을 이용한 단일채널 SAR SLC 영상 내 지상 이동물체의 탐지방법)

  • Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.2
    • /
    • pp.185-205
    • /
    • 2014
  • SAR ground moving target indicator (GMTI) has long been an important issue for SAR advanced applications. As spatial resolution of space-borne SAR system has been significantly improved recently, the GMTI becomes a very useful tool. Various GMTI techniques have been developed particularly using multi-channel SAR systems. It is, however, still problematic to detect ground moving targets within single channel SAR images while it is not practical to access high resolution multi-channel space-borne SAR systems. Once a ground moving target is detected, it is possible to retrieve twodimensional velocities of the target from single channel space-borne SAR with an accuracy of about 5 % if moving faster than 3 m/s. This paper presents a quick-and-dirty method for detecting ground moving targets from single channel SAR single-look complex (SLC) images by differentiation. Since the signal powers of derivatives present Doppler centroid and rate, it is very efficient and effective for detection of non-stationary targets. The derivatives correlate well with velocities retrieved by a precise method with a correlation coefficient $R^2$ of 0.62, which is well enough to detect the ground moving targets. While the approach is theoretically straightforward, it is necessary to remove the effects of residual Doppler rate before finalizing the ground moving target candidates. The confidence level of results largely depends on the efficiency and effectiveness of the residual Doppler rate removal method. Application results using TerraSAR-X and truck-mounted corner reflectors validated the efficiency of the method. While the derivatives of moving targets remain easily detectable, the signal energy of stationary corner reflectors was suppressed by about 18.5 dB. It results in an easy detection of ground targets moving faster than 8.8 km/h. The proposed method is applicable to any high resolution single channel SAR systems including KOMPSAT-5.

A Compact Optical System for Measurement of Vibration (미세변위 진동측정을 위한 광학 시스템 설계 및 제작)

  • Hwang, Woong;Kwon, Jin-Hyuk
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.208-209
    • /
    • 2002
  • 지금까지의 광학적 비접촉 진동 측정 시스템에서는 레이저도플러 효과를 이용하고 있다(1)(2). 그러나 이는 시스템 자체가 너무 크고 많은 장비들을 요구하는 단점을 가지고 있다. 본 실험은 장비의 속도와 크기를 개선하기 위해 이전까지의 방법과는 다른 시스템을 구성하여, 빠르게 회전하거나 진동하는 물체의 진동을 쉽고 간결하게 측정할 수 있는 장비와 프로그램을 설계, 제작하였다. 광원으로는 파장이 650nm인 LD(laser diode)를 사용하였고, 신호검출에는 1차원 PSD(position-sensitive detection)를 사용하여 시스템을 소형으로 구성하였다. (중략)

  • PDF

은밀 수중음향통신

  • Kim, Gi-Man
    • Information and Communications Magazine
    • /
    • v.33 no.8
    • /
    • pp.82-88
    • /
    • 2016
  • 본고에서는 은밀 수중음향통신과 관련한 연구동향과 수중 채널 환경의 특징들에 대해 소개한다. 육상 무선통신 환경과 마찬가지로 수중 채널에서도 전달 손실, 다중경로 전달, 도플러 효과 및 잡음이 장애 요인으로 작용하나 물 속의 상황을 정확히 예측하기 어렵고 시간에 따른 변동성이 매우 심하기 때문에 통신 시스템 설계를 어렵게 한다. 이러한 장애 요인들을 극복하면서 은밀 수중음향통신으로써 대표적인 대역확산 기법과 함께 수중 생체 모방형 신호를 사용하는 방법을 소개하고, 실제 국내 해역에서 획득한 데이터를 이용한 결과들을 제시한다.

Observation of suspended sediment concentration profiles from ADP (음향도플러유속계(ADP)를 이용한 부유사 농도 관측)

  • 오병철;추용식;정병순
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.294-297
    • /
    • 2002
  • ADP(Acoustic Current Profiler)는 수중에서 음파를 발사하여 해수와 함께 유동하는 부유입자에 의하여 반사되는 음향의 Doppler 효과를 이용하여 여러 개의 수층에서 유속과 유향을 측정하는 장비이다. Doppler 효과에 의한 반사음향의 주파수 천이가 부유입자의 속도에 따라 달라지는 것을 이용하여 해수의 흐름을 관측할 수 있다. (중략)

  • PDF

The Study on Performance of Propeller Fan according to Distance of Front Plate (프로펠라 팬과 앞판과의 간격이 팬 성능에 미치는 영향에 관한 연구)

  • 엄윤섭;부정숙;윤인철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.494-501
    • /
    • 2000
  • A study on performance of a propeller fan according to the distance between the front plate and the fan was conducted experimentally. Different characteristics of performance were found on the performance curve. Flow measurements using the three dimensional LDV system show that the zone of recirculation exists around the fan. The differences of performance in changes of the distance occurs because the zone of recirculation is much wider at the distance of 24mm than at that of 30mm.

  • PDF

Study of Spectral Doppler Waveform Interpretation and Nomenclature in Peripheral Artery (말초 동맥 분광 도플러 파형 해석 및 명명법에 대한 고찰)

  • Ji, Myeong-Hoon;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.649-660
    • /
    • 2022
  • In 1959, Satomura used spectral Doppler ultrasound to express the velocity of red blood cells according to time change, and Kato defined a zero-base line that could tell the direction of blood flow, making it possible to know the direction of blood flow. This became the basis for the widely used classifications of Triphasic, Biphasic, and Monophasic. However, the above classification has limitations that confuse users with the meaning and timing of use in a clinical environment. As a result, the American Society for Vascular Medicine (SVM) and the Society for Vascular Ultrasound (SVU) A consensus document on Doppler waveform analysis was declared by the joint committee. This study tried to review this consensus and to suggest nomenclature and modifiers that can be used in the domestic vascular ultrasound clinical field. The joint committee formed by SVM and SVU recommended that the use of the triphasic waveform and the biphasic waveform be used as a multiphasic waveform rather than being used due to the ambiguity of interpretation. In addition, it was agreed to name the hybrid-type waveform, which is a monophasic and high-resistance waveform, which has always been a problem of interpretation in a clinical environment, as an intermediate resistive waveform. In addition, in order to increase the communication efficiency between the interpreter and the sonographer, waveform analysis was classified into a main descriptor and a modifier, and it was recommended to use a single nomenclature by unifying various synonyms. It is expected that this literature review will provide accurate arterial spectral Doppler waveform interpretation and an agreed-upon nomenclature to radiologists performing vascular ultrasound examination in clinical practice, and will be utilized as basic data that can contribute to the improvement of public health.