• Title/Summary/Keyword: 대형화재

Search Result 422, Processing Time 0.021 seconds

Effect of External Thermal Insulation Composite System with a Non-combustible Calcium Silicate Based Mineral on The Mitigation for Reducing Fast Spread of Flame (불연성 무기 단열재를 화재확산 방지구조로 적용한 외단열 마감시스템의 화재성능)

  • Lee, Jong-Chan;Park, Jong-Chul;Song, Hun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.397-403
    • /
    • 2016
  • As a building energy saving standard strengthened, The number of building installed external thermal insulation composite system(ETICS) using EPS insulation increased. But frequent fire accident in the buildings installed EIFS using EPS led to strengthening of building fire safety regulation. This study is for fire property of EPS ETICS reinforced with noncombustible calcium silicate-based mineral insulation as a fire spread prevention structure(FSPS). Fire test for large scale wall by ISO 13785-2 was applied and results showed EPS EIFS with FSPS got 3~8 times superior fire safety than normal EIFS by visual investigation. Temperature and heat flux measurement results, which data of upside of specimen were lower than downside, also supported fire safety of EIFS with FSPS.

Internet을 이용한 자동화재 속보 시스템

  • 이광식;김준영;유상식;김응식
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.05a
    • /
    • pp.235-240
    • /
    • 1998
  • 최근 건축물은 산업의 발달과 더불어 초고층화, 대형화 및 다기능화 추세에 있다. 이에 따라 화재 발생시 위험도는 점점 높아져 발생되는 인명 및 재산상의 피해 규모 또한 비례적으로 증가되고 있다. 과거의 화재 발생 추세를 보면 '92년부터 '96년까지는 연평균 22,596건의 화재가 발생하여 연평균 13.3%의 증가율을 보였으며 '96년도에는 전년에 비하여 9.9%가 증가하고 있는 실정이다. (중략)

  • PDF

위험물 저장탱크 화재시 주위인접 가연물 및 시설에 대한 영향의 실험적 연구

  • Park, Hyung-Ju;Kim, Hong;Kang, Young-Gu;Jung, Ki-Chang;Lee, Jung-Yoon
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.05a
    • /
    • pp.54-59
    • /
    • 2003
  • 위험물 저장탱크의 대형화 및 다양화에 따라 그 위험성이 증대되어 설계 단계에서부터 안전 측면을 고려한 설계를 하고 있기 때문에 다른 화재에 비하여 발생 빈도는 낮으나 위험물의 특성상 화재가 발생하면 대형화됨으로써 화재 진화의 어려움과 대규모 재산피해 및 인명피해를 유발항 위험성을 항상 내포하고 있다.(중략)

  • PDF

Fire-fighting Pump Approval Standard for Fire-fighting Trucks with an Additional Positive Displacement Pump (용적형 펌프를 추가한 소방자동차용 소방펌프의 성능 인정기준에 관한 연구)

  • Han, Yong-Taek;Sung, Ki-Chan;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.104-110
    • /
    • 2016
  • Positive displacement pumps with high pressure and water capacity are used large fires in various high-rise buildings. This study provides information for a performance approval standard of fire pumps for fire trucks based on centrifugal pump standards enacted in 2012. An experiment was conducted with a positive displacement pump for three levels of performance from the approval standard (V-1, 2, and 3). The efficiency of the pump was included in the reference, which requires the approval of 65% performance, the same as a centrifugal pump. The water pressure is between 1.5 and 2.5 MPa, and the required flow rate was established as at least $0.31m^3/min$ and up to $3.0m^3/min$. A relief valve was added to adjust the shut-off pressure due to the structural characteristics of the positive displacement pump. A strainer was also installed to prevent damage to the inside of the pump due to foreign matter. However, the strainer includes a difference from the positive displacement pump to operate without a vacuum pump and the centrifugal pump. This is due to the additional approval standard portion of the positive displacement pump, which is expected to be selected for more variety of fire-fighting equipment and proactive responses to fire suppression in a high-rise buildings and large fires. In conclusion, this approval standard was enacted in January 2016.

A study on assessment for combustion toxic gas of building finish materials by NFPA 269 (NFPA 269에 의한 건축물 마감재의 연소가스독성평가연구)

  • Chun, Ji-Hong;Lee, Jong-Chun;Choi, Jae-Bum;Cho, Nam-Wook
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.340-344
    • /
    • 2011
  • 건축물 마감재료의 연소시 발생되는 독성가스는 대형화재로 인한 인명피해의 주된 원인 중의 하나이다. 현행 건축법에서는 건축물마감재료에 대하여 동물의 평균행동정지시간을 측정하는 가스유해성시험을 실시하고 있다. 본 연구는 동물시험이 아닌 NFPA 269에 의한 유효량분율(FED: Fractional effective does)을 이용하여 건축물 마감재의 독성지수를 도출하였다. 현행 가스유해성 평가 방법에서 사용되는 채임버(피검상자)를 이용하여 적외선분광분석 및 산소분석기로 연소가스를 정량 분석하였으며, NFPA269에서 규정하는 FED를 도출하였다. 몇 가지 건축재료에 대한 가스유해성시험의 평균행동정지시간과 FED의 상대적인 비교를 통해 연소가스독성평가를 수행하였다.

  • PDF

A Study on the Evacuation of People used the evacuation model on Fire in Shopping Mall (피난 모델을 이용한 대형할인매장의 화재시 피난에 관한 연구)

  • 이수경;이상준
    • Fire Science and Engineering
    • /
    • v.14 no.4
    • /
    • pp.17-22
    • /
    • 2000
  • For life safety design of shopping mall, we selected a shopping mall, and calculated the evacuation time of means of egress. It is calculated by two kind of evacuation method. One is the computer simulation model, EXODUS. The other is Japan's method. Study way is a model structure study, selecting real shopping mall and setting scenario, calculating the evacuating time. result of study, evaluation time is very high. Therefore we confirmed that the building of means of egress is not fit to evacuation more the capacity of setting population.

  • PDF

연기거동을 고려한 대피프로그램 개발

  • Kim, Soo-Young;Lee, Chun-Ha;Kim, Eung-Sik;Kim, Hong;Kang, Young-Gu;Jung, Ki-Chang;Gu, Dong-Chul
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.05a
    • /
    • pp.237-241
    • /
    • 2002
  • 국내의 화재로 인한 대형 인명피해를 보면 대부분이 직접적인 화재의 열에 의한 것이 아니라 연기유동을 통한 유해가스들의 흡입을 통하여 또는 대피시 재실자들 간의 사고로 인하여 생기는 것으로서 이글 방지하기 위한 대책이 시급한 상황이다. 이 대책으로써 무엇보다도 건물내의 방화관리자나 건물내 거주자들에 대한 직접적인 교육이 필요하나 건물의 대형화 및 재실자들의 불확실성으로 인하여 교육의 어려움과 무엇보다도 화재의 특성상 실제상황과 같은 구현을 통하여 교육하기에는 불가능 한 실정이다.(중략)

  • PDF

A study on the mini fire engine development of the use ATV (ATV를 이용한 미니소방차 개발에 관한 연구)

  • Kim, Yoo-Shik;Kno, Sung-Wang;Joo, Jong-Kil
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.117-120
    • /
    • 2012
  • 현재 국내에서 발생하는 화재의 대부분은 밀집한 건물에 발생하는 화재이다. 이러한 건물화재의 특징은 초기진화에 실패할 경우 인접한 건물로 화재가 번져 대형 화재로 이어지며, 이로 인한 피해도 급증하게 된다. 또한 소방차 출동 시 도로여건이나 주 정차 차량 등 다양한 진입 장애물 등으로 화재지역으로 신속한 접근이 어려운 경우가 많다. 따라서 실효적 화재 진화 성능을 가진 방수시스템을 탑재한 소형화된 미니 소방차를 개발하고자 하며 아울러 고지대나 산림 화재의 초기 대응을 위해 험로(산악지형)에서도 주행이 가능한 ATV(All Terrain Vehicle)를 적용하고자 한다.

  • PDF

Fire extinguishing Performance of the Water mist nozzle for Accommodation of Cruise ships (특수선 및 크루즈선 거주구역용 미분무수 노즐의 화재진압성능평가 - 공공장소 화재시험 -)

  • Kwark, Ji-Hyun;Kim, Young-Han
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.141-146
    • /
    • 2010
  • 특수선(FPSO, Drillship)의 거주구역이나, 대형 여객선(크루즈선) 공간의 70% 이상을 차지하는 수용시설(accommodation) 즉, 객실, 라운지, 공공장소, 창고 등은 24시간 사람이 상주하는 구역임으로 화재로부터 완벽하게 보호되어야 한다. 이를 위해 국제해사기구(IMO)에서는 SOLAS II-2 Reg. 10.6과 FSS code Ch. 8에 적합한 미분무수 소화설비를 설치할 것을 강제화하고 있다. 이러한 미분무수 소화설비는 미분무수 노즐, 압력용기, 섹션밸브, 펌프유닛 등으로 구성되는데 특히 핵심부품인 미분무수 노즐은 IMO Res. MSC 265(84)에 따라 노즐성능시험 및 화재진압성능시험을 통해 형식승인을 득해야 한다. 본 연구에서 이러한 기준에 만족하는 미분무수 노즐을 개발하고자 선실 및 복도에 대한 화재시험에 이어 공공장소 화재시험을 수행하였으며, 두 가지 천장 높이에 대한 화재진압성능을 평가하였다.

  • PDF

Study of High-capacity Foam Discharging Systems for Full Surface Fire of Big Oil Tanks (대형 유류저장탱크 전면화재 대응을 위한 대용량포방사시스템 연구)

  • Im, Joo-Yeol;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.173-180
    • /
    • 2019
  • Oil tank fires need to be suppressed differently from other oil-related fires, due to the high-temperature flames and hot updraft above the tank, in the former case, that cause the destruction of large amounts of foam. We studied high-capacity foam discharge systems based on the standards of the American Petroleum Institute (API), National Fire Protection Association (NFPA), British Standard European Norm (BS EN), and the laws of Japan. The performance of a high-capacity foam discharge system was measured by conducting real fire experiments with model oil tanks. We concluded that lightweight and easily movable high-capacity foam discharge systems should be urgently introduced in domestic operations. Additionally, the obstacles faced by major tanks, such as long-distance installation of large-diameter fire hoses and narrowing of firefighting spaces, should be resolved depending on the conditions of the site.