• Title/Summary/Keyword: 단층촬영장치

Search Result 177, Processing Time 0.028 seconds

Development and Evaluation of Quality Assurance Worksheet for the Radiation Treatment Planning System (방사선치료계획 시스템의 정도관리 절차서 개발 및 유용성 평가)

  • Cho Kwang Hwan;Choi Jinho;Shin Dong Oh;Kwon Soo Il;Choi Doo Ho;Kim Yong Ho;Lee Sang Hoon
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.186-191
    • /
    • 2004
  • The periodic Quality Assurance (QA) of each radiation treatment related equipments is important one, but quality assurance of the radiation treatment planning system (RTPS) is still not sufficient rather than other related equipments in clinics. Therefore, this study will present and test the periodic QA program to compare, evaluation the efficiency of the treatment planning systems. This QA program is divided to terms for the input, output devices and dosimetric data and categorized to the weekly, monthly, yearly and non-periodically with respect to the job time, frequency of error, priority of importance. CT images of the water equivalent solid phantom with a heterogeneity condition are input into the RTPS to proceed the test. The actual measurement data are obtained by using the ion chamber for the 6 MV, 10 MV photon beam, then compared a calculation data with a measurement data to evaluate the accuracy of the RTPS. Most of results for the accuracy of geometry and beam data are agreed within the error criteria which is recommended from the various advanced country and related societies. This result can be applied to the periodic QA program to improve the treatment outcome as a proper model in Korea and used to evaluate the accuracy of the RTPS.

  • PDF

A Study on the exposure dose for the computed tomography (컴퓨터 단층촬영시 환자피폭선량에 관한 연구)

  • Kim, Moon-Chan;Lim, Jong-Suck;Park, Hyung-Ro;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.27 no.2
    • /
    • pp.21-27
    • /
    • 2004
  • This study was conducted to estimate absorbed radiation doses associated with CT examinations. We compared CT dose index between single detector CT and multi detector CT. To establish radiation dose criteria in CT examination in Korea, we measured radiation dose for CT examinations in Seoul and kyungki-do. The results obtained were as follows ; 1. Averaged CTDIW value per 100 mAs was $13.5{\pm}3.2\;mGy$, and ranged from 8.1 mGy to 19.1 mGy in head phantom, was $7.1{\pm}2.0\;mGy$, and ranged from 3.7 mGy to 10.9 mGy in body phantom. 2. CTDIW was 3.2 mGy(1.26 times) larger in multi detector CT than single detector CT in head phantom, and 2.1 mGy(1.34 times) larger in body phantom. 3. The dose was the highest in 4 channel multi detector CT, and followed 8 channel multi detector CT, 16 channel multi detector CT and single detector CT in head phantom. And the dose was the highest in 4 channel and 8 channel multi detector CT, and followed 16 channel multi detector CT and single detector CT in body phantom.

  • PDF

The Evaluation of Bone Scan and SPECT Before and After Treatment of TMD Patients (골관절염을 가진 측두하악장애 환자의 치료 전, 후 골스캔과 SPECT의 평가)

  • Kim, Byeong-Soo;Ahn, Yong-Woo;Ko, Myung-Yun;Park, June-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.57-67
    • /
    • 2005
  • The aim of this study was to evaluate bone scan(SUR) and SPECT(hot spot) in patients with TMJ osteoarthritis. 99mTc-MDP bone scan and SPECT were done in 27 patients, total 54 temporomandibular joints were examined with clinical examination, plain radiography. 42 TMJs were osteoarthritis and 12 TMJs were normal case, clinically diagnosed. We compared osteoarthritis group and control group of bone scan(SUR) and SPECT(hot spot). thus we compared before and after treatment of bone scan(SUR) and bone SPECT(hot spot) according to history, contributing factor, symptom degree, treatment, treatment period. The obtained results were as follows. 1. Bone scan(SUR) and SPECT(hot spot) activity of osteoarthritis group were higher than control group(P<0.05, P<0.01). 2. Bone scan(SUR) and SPECT(hot spot) activity were decreased after treatment at TMJ with osteoarthritis(P<0.01). 3. Bone scan(SUR) and SPECT(hot spot) activity were decreased at treatment group with splint(P<0.01, P<0.05). 4. Bone scan(SUR) and SPECT(hot spot) activity were decreased at Chronic group(P<0.01, P<0.05). 5. Bone scan(SUR) and SPECT(hot spot) activity were decreased at low noise NAS(<6) group(P<0.01,P<0.05). 6. Bone scan(SUR) and SPECT(hot spot) activity were decreased at TMD patient with parafunctional habit and without trauma history, psychosocial factor. 7. Bone scan(SUR) and SPECT(hot spot) activity were higher at before treatment required more treatment period.

Implementation of Radiotherapy Educational Contents Using Virtual Reality (가상현실 기술을 활용한 방사선치료 교육 콘텐츠 제작 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.409-415
    • /
    • 2018
  • The development of smart devices has brought about significant changes in daily life and one of the most significant changes is the virtual reality zone. Virtual reality is a technology that creates the illusion that a 3D high-resolution image has already been created using a display device just like it does in itself. Unrealized subjects are forced to rely on audiovisual materials, resulting in a decline in the concentration of practices and the quality of classes. It used virtual reality to develop effective teaching materials for radiology students. In order to produce a video clip bridge using virtual reality, a radiology clinic was selected to conduct two exposures from July to September 2017. The video was produced taking into account the radiology and work flow chart and filming was carried out in two separate locations : in the computerized tomography unit and in the LINAC room. Prior to filming the scenario and the filming route were checked in advance to facilitate editing of the video. Modeling and mapping was performed in a PC environment using the Window XP operating system. Using two leading virtual reality camera Gopro Hero, CC pixels were produced using a 4K UHD, Adobe, followed by an 8 megapixel resolution of $3,840{\times}2,160/4,096{\times}2,160$. Total regeneration time was performed in about 5 minutes during the production of using virtual reality to prevent vomiting and dizziness. Currently developed virtual reality radiation and educational contents are being used to secure the market and extend the promotion process to be used by various institutions. The researchers will investigate the satisfaction level of radiation and educational contents using virtual reality and carry out supplementary tasks depending on the results.

A Study of Various Filter Setups with FBP Reconstruction for Digital Breast Tomosynthesis (디지털 유방단층영상합성법의 FBP 알고리즘 적용을 위한 다양한 필터 조합에 대한 연구)

  • Lee, Haeng-Hwa;Kim, Ye-Seul;Lee, Youngjin;Choi, Sunghoon;Lee, Seungwan;Park, Hye-Suk;Kim, Hee-Joung;Choi, Jae-Gu;Choi, Young-Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.271-280
    • /
    • 2014
  • Recently, digital breast tomosynthesis (DBT) has been investigated to overcome the limitation of conventional mammography for overlapping anatomical structures and high patient dose with cone-beam computed tomography (CBCT). However incomplete sampling due to limited angle leads to interference on the neighboring slices. Many studies have investigated to reduce artifacts such as interference. Moreover, appropriate filters for tomosynthesis have been researched to solve artifacts resulted from incomplete sampling. The primary purpose of this study is finding appropriate filter scheme with FBP reconstruction for DBT system to reduce artifacts. In this study, we investigated characteristics of various filter schemes with simulation and prototype digital breast tomosynthesis under same acquisition parameters and conditions. We evaluated artifacts and noise with profiles and COV (coefficinet of variation) to study characteristic of filter. As a result, the noise with parameter 0.25 of Spectral filter reduced by 10% in comparison to that with only Ramp-lak filter. Because unbalance of information reduced with decreasing B of Slice thickness filter, artifacts caused by incomplete sampling reduced. In conclusion, we confirmed basic characteristics of filter operations and improvement of image quality by appropriate filter scheme. The results of this study can be utilized as base in research and development of DBT system by providing information that is about noise and artifacts depend on various filter schemes.

An Efficient Correction Process of CT-Simulator Couch with Current Diagnostic CT Scanners (진단용 CT-모의치료기 테이블의 효율적인 교정 방법)

  • Goo, Eun-Hoe;Lee, Jae-Seung;Cho, Jung-Keun;Moon, Seong-Kwon
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.254-261
    • /
    • 2009
  • This study suggested that the table of CT-simulator and the laser alignment system using diagnostic CT scanner have an efficient method for improvement in alignment between the planned target center of traverse image with CT scanner. It was conducted on the daily QA when presented in the AAPM TG66 with correcting the laser alignment system using geometric trigonometric functions and investigated the effectiveness of correction methods as compared with those before and after correction. Before correction error was 3.82mm between the planned target center of image, the table longitudinal axis was twisted with 0.436o. The laser alignment system using geometric trigonometric functions in after correction was satisfied with tolerance limits of ${\pm}2mm$ when occurred about 0.7mm in errors between the planned target center. The table correction to satisfy the geometric accuracy is very inefficient over against the time and economic loss as well as technical limits in the case of application as only radiation therapy associated with CT-simulator with diagnostic CT scanner in use. But, the method which corrects the laser alignment system is economic and relatively simple with possibility of getting well geometric accuracy and we suppose that it is efficient method for applying in the clinic.

3-Dimensional Dosimetry of Small Field Photon Beam (광자선의 소조사면에서의 3차원적 선량 측정)

  • Jang, Ji-Sun;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.54-61
    • /
    • 2012
  • A polymer gel dosimeter was fabricated. A 3-dimensional dosimetry experiment was performed in the small field of the photon of the cyberknife. The dosimeter was installed in a head and neck phantom. It was manufactured from the acrylic and it was used in dosimetry. By using the head and neck CT protocol of the CyberKnife system, CT images of the head and neck phantom were obtained and delivered to the treatment planning system. The irradiation to the dosimeter in the treatment planning was performed, and then, the image was obtained by using 3.0T magnetic resonance imaging (MRI) after 24 hours. The dose distribution of the phantom was analyzed by using MATLAB. The results of this measurement were compared to the results of calculation in the treatment planning. In the isodose curve on the axial direction, the dose distribution coincided with the high dose area, 0.76mm difference on 80%, rather than the low dose area, 1.29 mm difference on 40%. In this research, the fact that the polymer gel dosimeter and MRI can be applied for analyzing a small field in a 3 dimensional dosimetry was confirmed. Moreover, the feasibility of using these for the therapeutic radiation quality control was also confirmed.

Finite element analysis of the effects of mouthguard produced by combination of layers of different materials on teeth and jaw (다양한 물성을 혼용하여 제작된 구강보호장치가 치아 및 악골에 미치는 영향)

  • So, Woong-Seob;Lee, Hyun-Jong;Choi, Woo-Jin;Hong, Sung-Jin;Ryu, Kyung-Hee;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.324-332
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the stress distribution of teeth and jaw on load by differentiating property of materials according to each layer of widely used mouthguard. Materials and methods: A Korean adult having normal cranium and mandible was selected to examine. A customized mouthguard was constructed by use of DRUFOMAT plate and DRUFOMAT-TE/-SQ of Dreve Co. according to Signature Mouthguard system. The cranium was scanned by means of computed tomography with 1mm interval. It was modeled with CANTIBio BIONIX/Body Builder program and simulated and interpreted using Alter HyperMesh program. The mouthguard was classified as follows according to the layers. (1) soft guard (Bioplast)(SG) (2) hard guard (Duran)(HG) (3) medium guard (Drufomat)(MG) (4) soft layer + hard layer (SG + HG) (5) hard layer + soft layer (HG + SG) (6) soft layer + hard layer + soft layer (SG + HG + SG) (7) hard layer + soft layer + hard layer (HG + SG + HG) The impact locations on mandible were gnathion, the center of inferior border, and the anterior edge of gonial angle. And the impact directions were oblique ($45^{\circ}$). The impact load was 800 N for 0.1 sec. The stress distribution was measured at maxillary teeth, TMJ and maxilla. The statistics were conducted using Repeated ANOVA and in case of difference, Duncan test was used as post analysis. Results: In teeth and maxilla, the mouthguard contacting soft layer of mandibular teeth presented lowest stress measure and, in contrast, in condyle, the mouthguard contacting hard layer of mandibular teeth presented lowest stress measure. Conclusion: For all impact directions, soft layer + hard layer + soft layer, the mouthguard with three layers which the hard layer is sandwiched between two soft layers, showed relatively even distribution of stress in impact.

Patients Setup Verification Tool for RT (PSVTS) : DRR, Simulation, Portal and Digital images (방사선치료 시 환자자세 검증을 위한 분석용 도구 개발)

  • Lee Suk;Seong Jinsil;Kwon Soo I1;Chu Sung Sil;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.100-106
    • /
    • 2003
  • Purpose : To develop a patients' setup verification tool (PSVT) to verify the alignment of the machine and the target isocenters, and the reproduclbility of patients' setup for three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT). The utilization of this system is evaluated through phantom and patient case studies. Materials and methods : We developed and clinically tested a new method for patients' setup verification, using digitally reconstructed radiography (DRR), simulation, porial and digital images. The PSVT system was networked to a Pentium PC for the transmission of the acquired images to the PC for analysis. To verify the alignment of the machine and target isocenters, orthogonal pairs of simulation images were used as verification images. Errors in the isocenter alignment were measured by comparing the verification images with DRR of CT Images. Orthogonal films were taken of all the patients once a week. These verification films were compared with the DRR were used for the treatment setup. By performing this procedure every treatment, using humanoid phantom and patient cases, the errors of localization can be analyzed, with adjustments made from the translation. The reproducibility of the patients' setup was verified using portal and digital images. Results : The PSVT system was developed to verify the alignment of the machine and the target isocenters, and the reproducibility of the patients' setup for 3DCRT and IMRT. The results show that the localization errors are 0.8$\pm$0.2 mm (AP) and 1.0$\pm$0.3 mm (Lateral) in the cases relating to the brain and 1.1$\pm$0.5 mm (AP) and 1.0$\pm$0.6 mm (Lateral) in the cases relating to the pelvis. The reproducibility of the patients' setup was verified by visualization, using real-time image acquisition, leading to the practical utilization of our software Conclusions : A PSVT system was developed for the verification of the alignment between machine and the target isocenters, and the reproduclbility of the patients' setup in 3DCRT and IMRT. With adjustment of the completed GUI-based algorithm, and a good quality DRR image, our software may be used for clinical applications.

A Study of Energy Dependency in Intensity Modulated Radiation Therapy of Lung Cancer (폐암환자의 세기조절방사선치료에서 에너지에 따른 선량분포 특성 비교)

  • Kim, Sung-Kyu;Kim, Myung-Se;Yun, Sang-Mo
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.191-199
    • /
    • 2008
  • PTV considered for the energy, dose distribution exposed to lung and spinal cord, and the characteristic of DVH(Dose Volume Histogram) were compared and investigated by planning the intensity modulated radiation therapy (IMRT) using the photon energies of 6 MV and 10 MV according to tumor location like as the anterior, middle, and posterior regions of lung, and the mediastinum region in lung cancer patients. Our institution installed the linear accelerator (Varian 21 EX-s, USA) equipped with 120 multileaf collimator for lung cancer patients, which is producing the photon energies of 6 MV and 10 MV, and radiation therapy planning was performed with ECLIPSE system (Varian, SomaVision 6.5, USA), which support inverse treatment planning. The tomographic images of 3 mm slice thickness for lung cancer patients were acquired using planning CT, and acquired tomographic images were sent to the Varis system, and then treatment planning was performed in the ECLIPSE system. The radiation treatment planning of the IMRT was processed from various angles according to the regions of the tumor, and using various beam lines according to the size and location of the tumor. The investigation of the characteristic of dose distributions for the energy of 6 MV and 10 MV according to tumor locations in lung cancer patients resulted that the maximum dose of 10 MV energy was 1.2% less than that of 6 MV energy without depending on the tumor location of lung cancer, and the reduction effects of MU were occurred from 10 to 25 MU. Radiation dose exposed to the lung satisfied the less 30% of V20, however radiation dose in 6 MV energy was from 0.1% to 0.5% less than that in 10 MV energy. Radiation dose exposed to the spinal cord for 6 MV energy was from 0.6% to 2.1% less than that for 6 MV energy.

  • PDF