• Title/Summary/Keyword: 다중치료중심

Search Result 32, Processing Time 0.02 seconds

Fractionated Stereotactic Radiotherapy (FSRT) Using Gold Markers : A Comparison of the Isocenter between Multiple Arcs and Static Conformal Beams (금속표지자를 이용한 다중호형 정위방사선치료와 입체조형 정위방사선치료의 회전중심점 비교)

  • 장지영;김기환;김재성;김준상;송창준;김선환;조문준
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.28-33
    • /
    • 2003
  • The aim of the study was to assess the isocenter deviation between multiple arcs and conformal beams in frameless FSRT. Forty seven patients received single isocenter radiosurgery or therapy (SRS/T) using available framelss FSRT system from Aug. 1997 to Dec. 2m. In choosing multiple arc FSRT or conformal FSRT, we had considered one of two techniques with respect to tumor size and tumor shape. In multiple arc FSRT, the average and standard deviation (SD) of the isocenter deviation was 0.2 mm (SD 0.2 mm), 0.2 mm (SD 0.2) and 0.3 mm (SD 0.2 mm)in the lateral (x), anterior-posterior (y) and cranio-caudal directions (z). In conformal FSRT, the average deviation and SD of the isocenter deviation was 0.2 mm (SD 0.2 mm), 0.3 mm(0.2 mm) and 0.4 mm (SD 0.2 mm) in the x, y and z directions. The average spacial deviation ($\Delta$r) was 0.41 mm and 0.54 mm in multiple arcs and conformal beams, respectively. The isocenter deviation using frameless FSRT system was similar value between multiple arcs and conformal beams. In practice, we believed we can select the appropriate treatment technique according to tumor shape and size.

  • PDF

Examination of Dose Change at the Junction at the Time of Treatment Using Multi-Isocenter Volumetric Modulated Arc Therapy (용적조절호형방사선치료(VMAT)의 다중치료중심(Multi- Isocenter)을 이용한 치료 시, 접합부(Junction)의 선량 변화에 대한 고찰)

  • Jung, Dong Min;Park, Kwang Soon;Ahn, Hyuk Jin;Choi, Yoon Won;Park, Byul Nim;Kwon, Yong Jae;Moon, Sung Gong;Lee, Jong Oon;Jeong, Tae Sik;Park, Ryeong Hwang;Kim, Se young;Kim, Mi Jung;Baek, Jong Geol;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.9-14
    • /
    • 2021
  • This study examined dose change depending on the reposition error of the junction at the time of treatment with multi-isocenter volumetric modulated arc therapy. This study selected a random treatment region in the Arccheck Phantom and established the treatment plan for multi-isocenter volumetric modulated arc therapy. Then, after setting the error of the junction at 0 ~ 4 mm in the X (left), Y (upper), and Z (inner and outer) directions, the area was irradiated using a linear accelerator; the point doses and gamma indexes obtained through the Phantom were subsequently analyzed. It was found that when errors of 2 and 4 mm took place in the X and Y directions, the gamma pass rates (point doses) were 99.3% (2.085) and 98% (2.079 Gy) in the former direction and 98.5% (2.088) and 95.5% (2.093 Gy) in the latter direction, respectively. In addition, when errors of 1, 2, and 4 mm occurred in the inner and outer parts of the Z direction, the gamma pass rates (point doses) were found to be 94.8% (2.131), 82.6% (2.164), and 72.8% (2.22 Gy) in the former part and 93.4% (2.069), 90.6% (2.047), and 79.7% (1.962 Gy) in the latter part, respectively. In the X and Y directions, errors up to 4 mm were tolerable; however, in the Z direction, error values exceeding 1 mm were beyond the tolerance level. This suggests that for high and low dose areas, errors in the direction same as the progress direction in the treatment region have a more sensitive dose distribution. If the guidelines for set-up errors are established at the institutional level through continuous research in the future, it will be possible to provide good quality treatment using junctions.

A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife (입체적횡다증회전조사를 병합한 방사선수술의 새로운 접근 : 포톤나이프)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.149-158
    • /
    • 1996
  • Purpose : To get an accute steepness of dose gradients at outside the target volume in intracranial lesion and a less limitation of beam selection avoiding the high dose at normal brain tissue, this Photon Knife Radiosurgery System was developed in order to provide the three-dimensional dose distribution through the reconstruction of CT scan and the combined stereotactic trans-multiarc beam mode based on linear accelerator photon beam. Materials and methods : This stereotactic radiosurgery, Photon Knife based on linear accelerator photon beam was provided the non-coplanar multiarc and trans-multiarc irradiations. The stereotactic trans-multiarc beam mode can be obtained from the patient position in decubitus. This study has provided the 3-dimensional isodose curve and anatomical structures with the surface rendering technique. The dose distribution from the combined two trans-multiarcs (2M 2TM) was compared to that of four non-coplanar multiarcs (4M) with same collimator size of 25 mm in a diameter and total gantry movements. Results : In this study, it shows that the dose distributions of stereotactic beam mode are significantly depended on the selected couch and gantry angle in same collimator size. Practical dose distribution of combined stereotactic trans-multiarc beam has shown a more small rim thickness than that of the non-coplanar multiarc beam mode in axial, sagittal and coronal plane in our study. 3-Dimensional dose line displayed with surface rendering of irregular target shape is helpful to determine the target dose and to predict the prognosis in follow-up radiosurgery. Conclusions : 3-Dimensional dose line displayed with surface rendering of irregular target shape is essential in stereotactic radiosurgery. This combined stereotactic trans-multiarc beam has shown a less limitation of the selection couch and gantry beam angles for the target surrounding critical organs. It has shown that the dose distribution of combined trans-multiarc beam greatly depended on the couch and gantry angles. In our experiments, the absorbed dose has been decreased to $27%$ / mm in maximum at the interval of $50\%$ to $80\%$ of isodose line.

  • PDF

A study on the effect of collimator angle on PAN-Pelvis volumetric modulated arc therapy (VMAT) including junction (접합부를 포함한 PAN-전골반암 VMAT 치료 계획 시 콜리메이터 각도의 영향에 관한 고찰)

  • Kim, Hyeon Yeong;Chang, Nam Jun;Jung, Hae Youn;Jeong, Yun Ju;Won, Hui Su;Seok, Jin Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.61-71
    • /
    • 2020
  • Purpose: To investigate the effect of collimator angle on plan quality of PAN-Pelvis Multi-isocenter VMAT plan, dose reproducibility at the junction and impact on set-up error at the junction. Material and method: 10 adult patients with whole pelvis cancer including PAN were selected for the study. Using Trubeam STx equipped with HD MLC, we changed the collimator angle to 20°, 30°, and 45° except 10° which was the default collimator angle in the Eclipse(version 13.7) and all other treatment conditions were set to be the same for each patient and four plans were established also. To evaluate these plans, PTV coverage, coverage index(CVI) and homogeneity index (HI) were compared and clinical indicators for each treatment sites in normal tissues were analyzed. To evaluate dose reproducibility at the junction, the absolute dose was measured using a Falmer type ionization chamber and dose changes at the junction were evaluated by moving the position of the isocenter in and out 1~3mm and setting up the virtual volume at the junction. Result: CVI mean value was PTV-45 0.985±0.004, PTV-55 0.998±0.003 at 45° and HI mean value was PTV-45 1.140±0.074, and PTV-55 1.031±0.074 at 45° which were closest to 1. V20Gy of the kidneys decreased by 9.66% and average dose of bladder and V30 decreased by 1.88% and 2.16% at 45° compared to 10° for the critical organs. The dose value at the junction of the plan and the actual measured were within 0.3% and within tolerance. At the junction, due to set-up error the maximum dose increased to 14.56%, 9.88%, 8.03%, and 7.05%, at 10°, 20°, 30°, 45°, and the minimum dose decreased to 13.18%, 10.91%, 8.42%, and 4.53%, at 10°, 20°, 30°, 45° Conclusion: In terms of CVI, HI of PTV and critical organ protection, overall improved values were shown as the collimator angle increased. The impact on set-up error at the junction by collimator angle decreased as the angle increased and it will help improve the anxiety about the set up error. In conclusion, the collimator angle should be recognized as a factor that can affect the quality of the multi-isocenter VMAT plan and the dose at the junction, and be careful in setting the collimator angle in the treatment plan.

Hypofractionated Radiation Therapy for Early Glottic Cancer - Preliminary Results - (초기 성문암 환자에서의 소분할 조사법을 이용한 방사선치료 - 예비적 결과 -)

  • Wu Hong-Gyun;Hong Semie;Shin Seong Soo;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.301-305
    • /
    • 2001
  • Purpose : This study was peformed for the evaluation of the feasibility and toxicity of hypofractionated radiation therapy for early glottic cancer Methods and Materials : From February 1999 to February 2000, 20 patients with Histologically confirmed Stage I, II glottic cancer were enrolled into this study. There were 18 males and 2 females, the median age of the patients was 59 years. The distribution of stage distribution was as fellows; T1aN0-16 patients, T1bN0-1 patient, T2N0-3 patients. Eighteen patients underwent laryngomicroscopic biopsy only, and two patients underwent laser cordectomy. All patients received radical radiation therapy (2.5 Gy per fraction, 24 fractions, total 60 Gy). Median duration of treatment was 36 days (range $31\~45\;days$). Results : Radiation therapy were well tolerated. Most common acute reactions were odynophagia and hoarseness, and these reactions resolved after radiation therapy. There were one case of RTOG grade 3 odynophagia $(5\%)$, six cases of grade 3 hoarseness $(30\%)$. Response of radiation therapy was evaluated one month after completion of treatment. All patients revealed complete response. During follow up, total three cases of treatment failure were detected. two cases were local recurrence in 10 and 13 months of radiation therapy and one case was local recurrence and distant metastasis in 2 months of radiation therapy. Conclusion : This hypofractionated radiation therapy schedule was feasible and effective for control of early glottic cancer But longer follow up time would be required to assess the long-term disease control and the late complication by shortening radiation therapy duration.

  • PDF

Association Between Cognitive Impairment and Oral Health Related Quality of Life: Using Propensity Score Approaches (인지기능과 구강건강관련 삶의 질의 연관성에 대한 연구: 성향점수 분석과 회귀모델을 중심으로)

  • Cha, Suna;Bae, Suyeong;Nam, Sanghun;Hong, Ickpyo
    • Therapeutic Science for Rehabilitation
    • /
    • v.12 no.3
    • /
    • pp.61-77
    • /
    • 2023
  • Objective : This study analyzed the correlation between cognitive function and oral health-related quality of life (OHQoL). Methods : Demographic and clinical characteristics were extracted and utilized for subjects aged 45 years or older who participated in the 8th Korean Longitudinal Study on Aging in 2020. The dependent variable was the Geriatric Oral Health Assessment Index, and the independent variable was the level of cognitive function classified by the Mini-Mental State Examination scores. The analysis method used inverse probability of treatment weighting (IPTW). Then, the association between cognitive function and OHQoL was analyzed by multiple regression analysis. Results : Among the participants, 4,367 (71.40%) had normal cognition, 1,155 (18.89%) had moderate cognitive impairment, and 594 (9.71%) had severe cognitive impairment. As a result of analysis by applying IPTW, there was a negative correlation between the cognitive function group and OHQoL (normal vs. moderate: β = -2.534, p < .0001; normal vs. severe: β = -2.452, p < .0001). Conclusion : After propensity score matching, mild cognitive impairment showed a more negative association than severe cognitive impairment. Therefore, patients with cognitive impairment require oral health management education to improve OHQoL regardless of the level of cognitive impairment.

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

Pharmacotherapy in Neuropathic Pains: Evidence-Based Approach (만성 신경병성 통증의 약물 치료: 근거-중심의 약물 치료)

  • Cho, Sang-Hoon;Ahn, Yong-Woo;Ok, Soo-Min;Huh, Joon-Young;Ko, Myung-Yun;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.2
    • /
    • pp.139-146
    • /
    • 2011
  • Neuropathic pain is defined by "pain is initiated or caused by primary lesion or dysfunction in the nervous system" and several etiologic conditions can induce the neuropathic pains. Various groups of drugs are used to treat the neuropathic pains. Not depending on anecdotal case or habitual choice, to obtain the more effective pharmacotherapy, relative-comparison index is suggested through multiple analyses of clinical trials. Depending on relative-comparison index, first-line medications and second-line medications for neuropathic pain are recommended. To support the Quality of life in patients, selection of medication is made on such recommendations.

Effects of Lifestyle, Stress and Life Satisfaction on Sleep Quality in University Student : Focusing on Department of Occupational Therapy Students (대학생의 생활양식, 스트레스 및 삶의 만족도가 수면의 질에 미치는 영향 : 작업치료학과 대학생을 중심으로)

  • Hong, Mi-Young;Kang, Gu-Yong;Han, Jee-Su;Kim, Eun-Young
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.7
    • /
    • pp.159-168
    • /
    • 2021
  • The purpose of this study was to analyze the effects for lifestyle, stress and life satisfaction on sleep quality in university students. The participants were 46 university students attending the department of occupational therapy. Participants responded to responses to the lifestyle questionnaire and Morning and Evening Questionnaire-Korean version(MEQ-K). The levels of stress and life satisfaction reported by participants were obtained using the Korean version of Perceive Stress Test-4(K-PSS-4) and Korean version of Satisfaction With Life Scale(K-SWLS). The quality of sleep was assessed using Korean Modified Leeds Evaluation Questionnaire(KMLSEQ). An independent t-test, Pearson correlation analysis, and multiple regression analysis were performed to investigate factors related to quality of sleep. The analysis of correlations between health status, morning type of chronotype, and life satisfaction showed a significant positive correlation between quality of sleep. As a result of analyzing the quality of sleep according to the chronotype, the main family house and dormitory group showed higher sleep quality than the boarding group. As a result of the multiple regression analysis, the chronotype predicts quality of sleep. This study could provide information to improve the quality of sleep for university students by identify factors affecting sleep for university students in occupational therapy.

Influence of Creative Leadership and Self-Efficacy on College Adaptability : Focused on a Nursing College (창의적 리더십, 자아효능감이 학교적응력에 미치는 영향 : 일 간호대학을 중심으로)

  • Choi, Mi-Jung;Heo, Myoung
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.7
    • /
    • pp.487-495
    • /
    • 2019
  • The purpose of this study was to investigate the effect of creative leadership and self-efficacy on college adaptability of nursing students. For the study, 380 students of G city nursing students were subjected to creative leadership test, self-efficacy test and college adaptability test. Correlation analysis and multiple regression analysis were conducted through SPSS24.0 program. The results of this study were as follows: First, college adaptability showed a positive correlation with self-efficacy and subordinate factors of creative leadership such as personal leadership, servant leadership, and problem-solving leadership. Second, as a result of the multiple regression analysis on the factors that showed significant difference in correlation, the factors that contribute to college adaptability were personal leadership, servant leadership, and self-efficacy in order of 41.1%.