Abstract
Purpose: To investigate the effect of collimator angle on plan quality of PAN-Pelvis Multi-isocenter VMAT plan, dose reproducibility at the junction and impact on set-up error at the junction. Material and method: 10 adult patients with whole pelvis cancer including PAN were selected for the study. Using Trubeam STx equipped with HD MLC, we changed the collimator angle to 20°, 30°, and 45° except 10° which was the default collimator angle in the Eclipse(version 13.7) and all other treatment conditions were set to be the same for each patient and four plans were established also. To evaluate these plans, PTV coverage, coverage index(CVI) and homogeneity index (HI) were compared and clinical indicators for each treatment sites in normal tissues were analyzed. To evaluate dose reproducibility at the junction, the absolute dose was measured using a Falmer type ionization chamber and dose changes at the junction were evaluated by moving the position of the isocenter in and out 1~3mm and setting up the virtual volume at the junction. Result: CVI mean value was PTV-45 0.985±0.004, PTV-55 0.998±0.003 at 45° and HI mean value was PTV-45 1.140±0.074, and PTV-55 1.031±0.074 at 45° which were closest to 1. V20Gy of the kidneys decreased by 9.66% and average dose of bladder and V30 decreased by 1.88% and 2.16% at 45° compared to 10° for the critical organs. The dose value at the junction of the plan and the actual measured were within 0.3% and within tolerance. At the junction, due to set-up error the maximum dose increased to 14.56%, 9.88%, 8.03%, and 7.05%, at 10°, 20°, 30°, 45°, and the minimum dose decreased to 13.18%, 10.91%, 8.42%, and 4.53%, at 10°, 20°, 30°, 45° Conclusion: In terms of CVI, HI of PTV and critical organ protection, overall improved values were shown as the collimator angle increased. The impact on set-up error at the junction by collimator angle decreased as the angle increased and it will help improve the anxiety about the set up error. In conclusion, the collimator angle should be recognized as a factor that can affect the quality of the multi-isocenter VMAT plan and the dose at the junction, and be careful in setting the collimator angle in the treatment plan.
Keywords
collimator angle; plan quality; junction; multi-isocenter VMAT;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 MOON, Sun Young, et al. Comparison of Dosimetric Parameters of Patient with Large and Pendulous Breast Receiving Breast Radiotherapy in the Prone versus Supine Position. Prog Med Phys DE, 2015, 26: 234-240.   DOI
2 Otto, Karl. "Volumetric modulated arc therapy: IMRT in a single gantry arc." Medical physics 35.1 (2008): 310-317.   DOI
3 Zhang, Wu-Zhe, et al. "A Dosimetric study of using fixed-jaw volumetric modulated arc therapy for the treatment of nasopharyngeal carcinoma with cervical lymph node metastasis." PloS one 11.5 (2016).
4 Otto K, Clark BG. Enhancement of IMRT delivery through MLC rotation. Phys Med Biol. 2002; 47: 3997.   DOI
5 Tas, B., Bilge, H., & Ozturk, S. T. (2016, March). An investigation of the dose distribution effect related with collimator angle for VMAT method. In AIP Conference Proceedings (Vol. 1722, No. 1, p. 150003). AIP Publishing LLC.
6 Kim, J. I., Ahn, B. S., Choi, C. H., Park, J. M., & Park, S. Y. (2018). Optimal collimator rotation based on the outline of multiple brain targets in VMAT. Radiation Oncology, 13(1), 88.   DOI
7 Kim, Yong Ho, et al. "Effect of collimator angles on the dosimetric results of volumetric modulated arc therapy planning for patients with a locally-advanced nasopharyngeal carcinoma." Journal of the Korean Physical Society 70.5 (2017): 539-544.   DOI
8 Son, Sang Jun, et al. "Evaluating efficiency of Coaxial MLC VMAT plan for spine SBRT." The Journal of Korean Society for Radiation Therapy 26.2 (2014): 313-320.
9 Tas, B., Bilge, H., & Ozturk, S. T. (2016). An investigation of the dose distribution effect related with collimator angle in volumetric arc therapy of prostate cancer. Journal of Medical Physics/Association of Medical Physicists of India, 41(2), 100.   DOI
10 Li, M. H., Huang, S. F., Chang, C. C., Lin, J. C., & Tsai, J. T. (2018). Variations in dosimetric distribution and plan complexity with collimator angles in hypofractionated volumetric arc radiotherapy for treating prostate cancer. Journal of applied clinical medical physics, 19(2), 93-102.   DOI
11 DIMITRI, F. Y., et al. Organ at risk dose verification in nasopharyngeal cancer VMAT planning with collimator comparison between single arc and double arc. In: IOP Conference Series: Materials Science and Engineering. IOP Publishing, 2018. p. 012024.
12 Isa M, Ur Rehman J, Afzal M, Chow J. Dosimetric dependence on the collimator angle in prostate volumetric modulated arc therapy. Int J Cancer Ther Oncol. 2014; 2: 020419.   DOI
13 Slosarek, K., Braclik, I., Leszczynski, W., Kopczynska, J., Osewski, W., & Wendykier, J. (2019). IMRT/VMAT dose distributions generated for HD® and Millennium® collimators TrueBeam® and Clinac® accelerators. Reports of Practical Oncology & Radiotherapy, 24(1), 20-27.   DOI
14 Lee, Y. K., Brooks, C. J., Bedford, J. L., Warrington, A. P., & Saran, F. H. (2012)Development and evaluation of multiple isocentric volumetric modulated arc therapy technique for craniospinal axis radiotherapy planning. International Journal of Radiation Oncology* Biology* Physics, 82(2), 1006-1012.   DOI
15 Murtaza, G., Mehmood, S., Rasul, S., Murtaza, I., & Khan, E. U. (2018). Dosimetric effect of limited aperture multileaf collimator on VMAT plan quality: A study of prostate and head-and-neck cancers. Reports of Practical Oncology & Radiotherapy, 23(3), 189-198.   DOI
16 Kim, J. I., Ahn, B. S., Choi, C. H., Park, J. M., & Park, S. Y. (2018). Optimal collimator rotation based on the outline of multiple brain targets in VMAT. Radiation Oncology, 13(1), 88.   DOI
17 Wang, K., Meng, H., Chen, J., Zhang, W., & Feng, Y. (2018). Plan quality and robustness in field junction region for craniospinal irradiation with VMAT. Physica Medica, 48, 21-26.   DOI
18 Zeng, G. G., et al. "A two isocenter IMRT technique with a controlled junction dose for long volume targets." Physics in Medicine & Biology 52.15 (2007): 4541.   DOI
19 Meyer, J., Richter, A., Pfreundner, L., Guckenberger, M., Krieger, T., Schwab, F., & Flentje, M. (2009). An interlaced IMRT technique for elongated tumor volumes. Medical Dosimetry, 34(2), 170-178.   DOI
20 Lin, H., Ding, X., Kirk, M., Liu, H., Zhai, H., HillKayser, C. E., ... & McDonough, J. (2014). Supine craniospinal irradiation using a proton pencil beam scanning technique without match line changes for field junctions. International Journal of Radiation Oncology* Biology* Physics, 90(1), 71-78.
21 Strojnik, Andrej, Ignasi Mendez, and Primoz Peterlin. "Reducing the dosimetric impact of positional errors in field junctions for craniospinal irradiation using VMAT." Reports of Practical Oncology & Radiotherapy 21.3 (2016): 232-239.   DOI
22 Lee, Seungchul, and Youngjae Kim. "The Effect of Dose Distribution under Treatment Techniques on Cerebrospinal Irradiation." Journal of the Korean Society of Radiology 10.1 (2016): 21-28.   DOI
23 McVicar, Nevin. "Improved Volumetric Modulated Arc Therapy Field Junctions Using In Silico Base Plans: Application to Craniospinal Irradiation." Journal of Medical Imaging and Radiation Sciences 49.3 (2018): 301-308.   DOI
24 Myers, Pamela, et al. "Evaluation of localization errors for craniospinal axis irradiation delivery using volume modulated arc therapy and proposal of a technique to minimize such errors." Radiotherapy and Oncology 108.1 (2013): 107-113.   DOI
25 Otto K. Letter to the Editor on 'Single-Arc IMRT?' phys Med Biol2009;54:L37-41.   DOI