• Title/Summary/Keyword: 다중이용업소

Search Result 45, Processing Time 0.033 seconds

A Study on the Application of the Regulation of the Interior Materials in Entertainment Occupancy (다중이용업소의 내장재 규정의 적용에 관한 연구)

  • 이주헌;윤명오;김운형
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.100-107
    • /
    • 2001
  • A Interior material, a main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Nonetheless, it has been used recklessly with undue attention to its contribution to fire in particular in entertainment occupancy and causes many victims in fire. Therefore, this study attempts to examine the current use of interior material in Korea and find out what to be improved and enhanced in terms of related regulations. Based on the comparison and analysis of the Korea regulation with those of advanced nations, suggestions are made for an effective and efficient improvement and complement to the current system. What can be suggested from this study are as follows. The use of interior material should be controlled under the unified regulation of fire-safety codes. Code should be set up so that the current construction enforcement should be applied in retroactive to those entertainment buildings that obtained a license prior to the implementation of the system certifying that the building is fire-resistant and fire-protective. The legislation should be made to control the fire-protection facilities of small-sized, underground entertainments. It should be obliged to present the blueprint displaying the use of interior material at the time of changing occupancy. Or, it should be compelled to report changes that go way without permit to the administrative office. A compulsory provision should be set up to have a fire-resistant performance to movable furniture. The classification index designating the fire hazard of interior material by flame spread rate and smoke toxicity and its test method should be established.

  • PDF

VR Theme Park Regulatory Improvement Plan (VR 테마파크 규제개선방안)

  • Song, Seung-Keun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.12
    • /
    • pp.1653-1658
    • /
    • 2018
  • This study aims to analyze the cases of VR space to improve the regulations. The space is divided according to the multi-use business act when the VR simulator and the VR game are simultaneously installed in a single space. It is necessary to amend the rules of the Tourism Promotion Act so that it can operate at a certain area of the youth game room subject to the Game Industry Law. Amendments that do not compartmentalize a space partition in the Multi-use Business Act should be carried out simultaneously. This is safer alternative by collective management rather than by the safety applied within a limited space by eliminating the compartment by industry. This is a legal amendment that allows VR simulator and VR game to be operated in the same space even in small sized amusement facilities such as other amusement facilities. This regulatory improvement plan is expected to help the activation of small sized VR theme parks.

한국관광의1번지.강원도의 화장실 정비시책

  • 문남수
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.2
    • /
    • pp.22-26
    • /
    • 2002
  • 한국관광의 1번지 강원도는$\ulcorner$'99강원 국제관광 EXPO$\lrcorner$를 계기로 접객업소 등 다중이 이용하는 모든 화장실을 문화와복지 . 환경을 생각하는 아름다운 화장실로 개선하고 있으며, 특히, 관광지별로$\ulcorner$테마가 있는 화장실$\lrcorner$ 만들어 특색있는 화장실 정비사업을 추진하고 있다.

  • PDF

A Study on the Fire Protection Safety of the Public-utilization Shops (다중이용업소의 소방안전기준에 관한 연구)

  • Kim, Yeob-rae
    • Journal of the Society of Disaster Information
    • /
    • v.5 no.2
    • /
    • pp.10-21
    • /
    • 2009
  • This study contains the fire protection safety of the public-utilization shops. The toll of fires in the public-utilization shops is so heavy in spite the less occurency. The shops are mostly compartmented into small rooms by partition wall which hinders the evacuation of the people on fire. This study provides additional requirements on the fire safety of the public-utilization shops needed for human life and property.

  • PDF

A Study on Using the Interior Finishing Material using Regulation at Multiple-using Businesses (다중이용업소 실내마감재료 사용기준에 관한 연구)

  • Kim, Yong-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.216-224
    • /
    • 2013
  • There are the relevant provisions that apply to building regulations about the Building codes, Fire Protection laws, and more Multi-using interior finish materials businesses etc. The differences between these regulations are as follows: The Building codes is defined the main use of the building according to facilities to used to set the scale by the use of the floor space, On the other hand, Fire Protection laws are the basic purpose and the act of using the architectural space(or sales) by separating object by fire. And Multiple-using Businesses Facilities consist of two regulations engaged in the kind of law and the size of the floor area. One building can not be based on operating facilities and together in Multiple use businesses Law. As such, the Buildings are applied to the Building codes, Fire Protection laws, such as Multi-using Businesses Facilities interior construction industry due to the structural differences in the position of the designer feeling a lot of difficulties and confusion. The Multi-use businesses Facilities engage in the kind of law, the size of the floor area and seating capacity. These can not be based on operating facilities, and consists of two regulations together in one building. This study is purposed to help improving the finish of the interior architecture that is related to the Building code regulations, Fire Protection laws, Multi-using Facilities interior finishing material relevant with the provisions from the law through analyze the case of developed countries, and the current Multiple use Businesses Facilities research range from the law of multiple-using facilities, interior finishing, interior architecture for supervision reasonably and compensation for the interior design. So, Result is as follows: First, interior decorations can be separated the fixed material and the moveable things. second, It should be included multi-using Business though small size business space at the basement floor. third, It should be established statute law that design and construction responsibility. forth, re-testing fire resist performance after some period. and finally, it need to mitigate regulation where be installed sprinkler.

A Case Study on Determination of Fire Causes for SAUNA FACILITY Fires Validate by CFD Fire & Smoke Simulation Modeling Method (화재시뮬레이션 S/W를 이용한 연소예측모델링기법에 의한 국내 사우나 시설의 화재원인규명을 위한 사례연구)

  • 박형주;신동철
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.358-374
    • /
    • 2002
  • 최근 빈번하게 발생하고 있는 사우나 등의 열을 방사하는 도크내에서 발생하는 화재사고는 다중이용업소를 이용하는 불특정한 사람들의 생명을 위협하고 있는 수준에 도달하고 있다. 특히 이런 시설의 화재는 화재발생 후에 소방대에 의한 진압에만 치중하고 있어 향후 계속하여 화재가 발생할 우려가 큼에도 불구하고 착화원인을 규명하는데 소홀히 하고있다. 특히 현장감식에 의한 육안조사만을 실시하여 화재원인을 추정하거나 설정하는 경우가 대부분이라 근본적인 대책을 세우지 못하고 있다. 따라서 본 연구에서는 육안조사 등에 의하여 설정한 착화원인을 과학적인 분석법 즉, EU국가에서 널리 사용하는 CFD(컴퓨터수치해석)시뮬레이션 S/W를 사용하여 연소모델링에 의한 검증조사기법을 적용하여 원인을 검증하는데 사용하여 국내화재조사기술의 과학화를 시도하였다.

  • PDF

Development of Automatic Operating System for Exit Door using RF (무선을 이용한 비상문 자동개폐 시스템 개발)

  • Lim Youn-Sub;Hwang Byung-Kon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • In this paper, we develop a control system with fire receiver and emergency light that controls (manages) emergency door by wireless signals which prevents crime but also helps evacuate in (fire) emergency. This automatic door operator can be installed on any buildings which have a problem of opening or shutting emergency doors, and it is especially good for buildings with high fire vulnerabilities such as complex buildings, apartments and multistoried buildings without easy control of rooftop doors.

  • PDF