• Title/Summary/Keyword: 다중셀유동

Search Result 9, Processing Time 0.022 seconds

Three-dimensional Detoantion Wave Dynamics in a Circular Tube (원형 관 내부에서의 3차원 데토네이션 파의 동적모형)

  • Cho, Deok-Rae;Won, Soo-Hee;Shin, Jae-Ryul;Choi, Jeong-Yeol
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.3
    • /
    • pp.68-75
    • /
    • 2008
  • The three-dimensional structure of detonation wave propagating in a circular tube was investigated using a parallel computational code developed previously. A series of parametric study for a circular tube of a fixed diameter gave the formation mechanism of the detonation cell structures depending on pre-exponential factor, k. The unsteady results in three-dimension showed the mechanisms of two, three and four cell mode of detonation wave front structures. The detonation cell number was increased but cell width and length were decreased with increased pre-exponential factor k. In the all multi-cell mode, the detonation wave structure and smoked-foil records on the wall are made by the moving of transverse waves. The detonation wave front structures have the regular polygon and windmill shapes periodically.

Numerical Simulation of the Fully Developed Flow and Heat Transfer of a Plate Heat Exchanger Taking into Account Variation in the Corrugation Height (주름높이의 변화를 고려한 판형열교환기의 완전발달유동 및 열전달 수치해석)

  • Moh, Jeong-Hah
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Numerical analysis has been carried out to investigate the fully developed flow and heat transfer characteristics of a plate heat exchanger. Multi-cell models with an inlet part and outlet part are used to perform the numerical simulation. The plate heat exchanger is characterized by a chevron angle of $20^{\circ}$ and a P/H ratio of 2.0~4.0. The working fluid is water and the Reynolds numbers range from 300 to 1,500. The correlation is given in the form of $f=CRe^m$ for the friction factor and $j=CRe^m$ for the Colburn factor. It is found that the fully developed flow starts from the third cell and the Nusselt number increases with decreasing P/H ratios.

A Subcarrier-based Virtual Multiple Antenna Technique for OFDM Cellular Systems (OFDM 셀룰러 시스템에서 부반송파 기반의 가상 다중안테나 기법)

  • Lee, Kyu-In;Ko, Hyun-Soo;Woo, Kyung-Soo;Ko, Yo-Han;Kim, Yeong-Jun;Ahn, Jae-Young;Cho, Yong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.10C
    • /
    • pp.981-990
    • /
    • 2006
  • In this paper, we introduce the concept of a subcarrier-based virtual multiple antennas (SV-MIMO) for OFDM cellular systems, where the multiple antenna techniques are performed on a set of subcarriers, not on the actual multiple antennas. The virtual multiple antenna system can support multiple users simultaneously as well as reduce inter-cell interference (ICI) form adjacent cells with a single antenna. Also, this technique is easily extended to multiple antenna environments. The virtual multiple antenna techniques can be divided into a virtual smart antenna technique and a virtual MIMO technique. Especially, this method effectively reduces ICI at cell boundary with frequency reuse factor equal to 1, and can support flexible resource allocation depending on the amount of interference. It is shown by simulation that the proposed method is superior to conventional method under the same condition of data transmission.

Thermal and flow characteristics of confined multiple slot jet impingement with exhaust ports (배기구를 가진 국한된 다중 슬롯 충돌제트의 열유동 특성)

  • Kang, Soo-Jin;Cho, Woo-Jin;Lee, Jong-Hyeok;Lee, Kwan-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.835-840
    • /
    • 2009
  • In this paper, confined multiple slot jet impingement with exhaust ports is investigated numerically. A flow cell, defined as volume sectioned by the impingement and confinement surfaces and the centerlines of adjacent nozzle and exhaust port, is chosen for computational domain. The effects of Reynolds number and geometrical parameters on the heat transfer performance and the flow characteristics are studied. For turbulence, the Abe-Kondoh-Nagano version of the low-Reynolds k-$\varepsilon$ model is employed. The results showed that the local Nusselt number distribution is shifted down and show poor heat transfer performance for small Reynolds number and small ratio of the lateral and axial length of flow cell. The rest of range, except the range of the shift phenomenon, can be classified into three groups by heat transfer characteristics.

  • PDF

Transition to Oscillatory Natural Convection in a Wide-gap Horizontal Cylindrical Annulus: Pr=0.1 (넓은 수평 환형 공간에서의 진동하는 자연 대류로의 천이 : Pr=0.1)

  • Yoo Joo-Sik;Kim Yong-Jin;Eom Yong-Kyoon
    • Journal of computational fluids engineering
    • /
    • v.5 no.3
    • /
    • pp.40-46
    • /
    • 2000
  • Natural convection in a wide-gap horizontal annulus is considered, and the transition of flows from steady to oscillatory convection is investigated for the fluid with Pr=0.1. The unsteady streamfunction-vorticity equation is solved with finite difference method. As Rayleigh number is increased, the steady crescent-shaped flow bifurcates to a time-periodic flow with like-rotating eddies. And afterwards, a transition to an oscillatory multicellular flow with a counter-rotating eddy on the top of the annulus occurs. A transition from steady to an oscillatory flow occurs, but dual solutions and hysteresis phenomena are not observed.

  • PDF

MULTIPLE SOLUTIONS IN NATURAL CONVECTION BETWEEN TWO HORIZONTAL PLATES WITH SMALL MAGNITUDE NON-UNIFORM TEMPERATURE IN THE UPPER PLATE (위 평판이 작은 불균일 온도를 갖는 두 수평 평판 사이의 자연 대류에서의 다중해)

  • Yoo, Joo-Sik
    • Journal of computational fluids engineering
    • /
    • v.21 no.3
    • /
    • pp.64-70
    • /
    • 2016
  • Multiple solutions in natural convection of water with Pr=7 between two horizontal plates with small magnitude non-uniform temperature distribution in the upper plate is numerically investigated. The dimensionless temperature of upper plate is ${\theta}={\epsilon}sinkx$. Two upright cells are formed over one wave length in the conduction-dominated regime of small Rayleigh number. However, multicellular convection occurs above a critical Rayleigh number for small wave number. When k = 1.5, dual solutions are found and a transition of $6{\rightarrow}4$ eddy flow occurs with decrease of Rayleigh number. When k = 0.75, two, three, four and five multiple solutions are observed. Transitions of $14{\rightarrow}12$, $12{\rightarrow}10$, $10{\rightarrow}8$ and $6{\rightarrow}8$ eddy flow occur with decrease of Rayleigh number.

Numerical investigation on the bifurcation of natural convection in a horizontal concentric annulus (수평동심환상공간내 자연대류의 다중해에 관한 수치적 연구)

  • Jeong, Jae-Dong;Kim, Chan-Jung;Lee, Jun-Sik;Yu, Ho-Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.2
    • /
    • pp.252-263
    • /
    • 1997
  • Steady-state two-dimensional natural convective heat transfer in horizontal cylindrical annuli was studied by solving the governing equations based on the primitive variables. Emphasis was put on the occurrence of the multiple solutions at a given set of parameter values, and on the determination of the bifurcation points at which those multiple solutions begin to branch out. The multicellular flow pattern from the results of melting process in an isothermally heated horizontal cylinder for high Rayleigh numbers, was used as initial guesses for the field variables. This was succeeded in new bifurcation point to tetracellular solutions for an identical set of parameter variables of previous works. The close examination of flow pattern transition around bifurcation point was also conducted. It was found that the mechanisms of flow transition are different depending on the critical Rayleigh number of bifurcation point.

Investigation of Flow and Heat Transfer Characteristics of Plate Heat Exchanger Taking into Account Entrance Effects and Variation in Corrugation Height (입구영향 및 주름높이의 변화를 고려한 판형열교환기의 유동 및 열전달 특성)

  • Moh, Jeong-Hah
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.965-973
    • /
    • 2010
  • Numerical analysis has been carried out to investigate the heat transfer characteristics of a plate heat exchanger. The multi-cell models with inlet part and outlet part are used for performing numerical simulation. The plate heat exchanger is characterized by chevron angle of $15^{\circ}$, corrugation pitch of 24mm and corrugation height 6~12mm. The length of the inlet-part considered in the analysis ranges from 24.8 to 124mm and Reynolds numbers range from 1,000 to 10,000. The correlations such as friction factor and Colburn factor are compared with previous experimental data. The results can be utilized for designing the plate heat exchanger.

Thermal instability during the melting process in an isothermally heated horizontal cylinder (등온가열 수평원관내 융해과정동안의 열적 불안정성)

  • Jeong, Jae-Dong;Yu, Ho-Seon;Lee, Jun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.6
    • /
    • pp.2046-2056
    • /
    • 1996
  • The constrained melting inside an isothermally heated horizontal cylinder has been repeatedly investigated in many studies only for the moderate Rayleigh numbers. This study extends the range of Rayleigh numbers to systematically investigate the transition during melting processes, especially focusing on the complex multi-cellular flow pattern and thermal instability. The enthalpy-porosity formulation, with appropriate source terms to account for the phase change, is employed. For low Rayleigh numbers, initially developed single-cell base flow keeps the flow stable. For moderate Rayleigh numbers, even small disturbances in balance between thermal buoyance force and viscous force result in branched flow structure. For high Rayleight numbers, Benard type convection is found to develop within a narrow gap between thee wall and the unmelted solid. The marginal Rayleigh number and the corresponding wave number are in excellent agreement with those from linear stability theory.