• Title/Summary/Keyword: 능동전력필터

Search Result 252, Processing Time 0.023 seconds

Stability Analysis of Current Control for Single-Phase Grid Converters with LLCL Input Filters (LLCL 입력필터를 갖는 단상 그리드 컨버터의 전류제어 안정도 해석)

  • Bae, Cheol-Ju;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.514-515
    • /
    • 2015
  • 본 논문은 LLCL 입력필터를 적용한 단상 그리드 컨버터에서 필터의 공진 감쇠를 위한 가상저항 기반의 능동 감쇠 기법을 이용한 전류제어 시스템의 안정도를 분석한다. LLCL 필터의 가상저항 값에 따른 안정도를 조사하고 PSIM 시뮬레이션을 통해 비교 분석한다.

  • PDF

Regeneration Inverter System for DC Traction with Hormonic Reduction Capability (고조파 저감 능력을 가진 직류전철 회생인버터 시스템)

  • Won, Chung-Yuen;Jang, Su-Jin;Kim, Yong-Ki;Bang, Hyo-Jin;Song, Sang-Hun;Ahn, Kyu-Bok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.96-104
    • /
    • 2004
  • This paper proposes a dc power regenerating systems, which can generate the excessive dc power from dc bus line to ac supply in substations for traction system The proposed regeneration inverter system for dc traction can be used as both an inverter and an active power filter(APF). As an regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three phase PWM inverters and composed of parallel inverters, output transformers, and an LCL filter.

Instantaneous Compensating Power Flow Graph of Active Power Filters Considering Rectification / Inversion Modes (정류와 역변환 모드를 고려한 능동전력필터의 순시 보상전력 흐름도)

  • 정영국;정찬수;배동관;안재영;김광헌;임영철
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.101-105
    • /
    • 1999
  • The goal of this paper is to present instantaneous compensating power flow of active power filters(APFs) by graphical method that could be practicable to compensate the power in both case of behaving in instantaneous rectifying mode and instantaneous inverting mode. To ensure the validity of the proposed method, computer simulation is achieved. Proposed method can be present more exquisite and physically meaningful power flow than conventional method in instantaneous compensating power flow Graph of APFs.

  • PDF

A Study on Control and Compensating Characteristics of Active Series Voltage Compensator with Harmonic Current Compensating Capability (고조파전류 보상 기능을 갖는 능동 직렬 전압보상기의 제어 및 보상특성에 관한 연구)

  • 이승요;김홍성;최규하;신우석;김홍근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.484-492
    • /
    • 2000
  • In this paper, a voltage compensator with harmonic current compensating capability is studied and its compensating characteristics are analyzed. Like the hybrid active power filter, the proposed system is composed of parallel LC passive filter and series PWM converter connected to power line through series transformer. It is shown that the compensation of harmonic current generated due to nonlinear loads such as diode rectifier and instantaneous voltage compensation of the source are performed through the proposed compensating system. The operating principle of the proposed system is described through a single-phase equivalent circuit and the control strategy is suggested on the d-q rotating reference frame of the 3-phase system. Also, experiment is carried out to verify compensating characteristics of the proposed system.

  • PDF

The Control of Single-Phase Active Power Filter Using Modified Synchronous Reference Frame Method (수정된 동기좌표계를 이용한 단상능동전력필터 제어)

  • Hso, Jin-Seok;Kim, Young-Seok;Kim, Young-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.281-284
    • /
    • 2003
  • 본 논문에서는 비선형 단상부하에 의해 발생하는 전류 고조파를 보상하기 위한 단상능동전력필터의 제어방법을 제안한다. 정규의 단상에 시간지연을 주어 가상의 두 번째 상을 만들어 단상시스템을 두 축을 갖는 직교 좌표로 변환시킬 수 있다. 두 개의 상은 3상 2상 변환에서 사용하는 것과 같이 직교 좌표 시스템을 만들 수 있다. 이 것은 순시 무효전력을 계산하는 방법인 복소계산을 가능하게 한다. 고정 좌표계에서 순시무효전력이론을 적용한 기존의 방법 대신, 본 논문에서는 수정된 동기 좌표계를 이용하여 정상분과 역상분을 계산하여 보상전류 지령치를 결정하였다. 제안된 방법은 고조파저감과 PF개선에 있어 우수한 성능을 보여준다. 시뮬레이션 패키지(PSIM)를 사용하여 모의실험을 하였으며, 제안된 방법의 유효성을 입증하였다.

  • PDF

A new continuous-time current-mode integrator for realization of low-voltage current-mode CMOS filter (저전압 전류모드 CMOS 필터 구현을 위한 새로운 연속시간 전류모드 적분기)

  • 방준호;조성익;김동용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.4
    • /
    • pp.1068-1076
    • /
    • 1996
  • In this paper, a new continuous-time current-mode integrator as basic building block of the low-voltage analyog current-mode active filters is proposed. Compared to the current-mode integrator which is proposed by Zele, the proposed current-mode integrator had higher unity gain frequency and output impedance in addition to lower power dissipation. And also, a current-mode third-order lowpass active filter is designed with the proposed current-mode integrator. The designed circuits are fabricated using the ORBIT's $1.2{\mu}{\textrm{m}}$ deouble-poly double-metal CMOS n-well process. The experimental results show that the filter has -3dB cutoff frequency at 44.5MHz and 3mW power dissipation with single 3.3V power supply and also $0.12mm^{2}$ chip area.

  • PDF

Comparative Study of Performance of Switching Control and Synchronous Notch Filter Control for Active Magnetic Bearings (능동 자기 베어링을 위한 동기 노치필터 제어기와 스위칭 제어기의 성능 비교 연구)

  • Yoo, Seong Yeol;Noh, Myounggyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.4
    • /
    • pp.511-519
    • /
    • 2013
  • Switching controllers for active magnetic bearings are claimed to minimize the copper losses because they do not use bias currents. In this study, we compare the performances of the switching controller with those of the widely used proportional-derivative (PD) controller. The PD controller is combined with a synchronous notch filter to reduce the effect of the unbalance disturbance. For a fair and objective comparison, the PD controller is designed systematically. The switching controller is designed so that the dynamics of the two controllers are almost identical. A system model is developed. This model includes the flexible modes of the rotor and the dynamics of the sensors and amplifiers. The simulation results show that the switching controller indeed reduces the copper loss at lower speeds. However, it fails to operate around the speed close to the bending mode of the rotor.

Single-Phase CHFL Converter with Buck-type Active Power Decoupling for EV On-board Charger (전기자동차 온-보드 충전기를 위한 벅-타입 능동 전력 디커플링이 적용된 단상 CHFL 컨버터)

  • Kim, Seung-Gwon;Baek, Ki-Ho;Park, Sung-Min;Chung, Gyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.328-329
    • /
    • 2018
  • 본 논문에서는 전기자동차용 단상 온-보드 충전기를 위한 Cycloconverter-type High Frequency Link 회로구조와 능동 전력 디커플링 회로를 이용한 전기자동차용 고전력밀도 양방향 온-보드 충전기를 제안한다. 제안된 시스템은 전력변환부 단계를 줄이기 위한 AC-AC 변환회로와 DC링크 캐패시터를 최대한 줄이기 위해서 벅-타입 능동 전력 필터를 사용한다. 이를 통해 전력변환시스템 전체의 부피를 줄일 수 있으며, 전해 커패시터를 필름 커패시터로 대체하여 수명 문제를 해결할 수 있다. 제안된 시스템의 성능은 MATLAB/Simulink 시뮬레이션을 통해 검증하였다.

  • PDF

Algorithm of Extended Current Synchronous Detection for Active Power Filters (능동전력필터를 위한 확장된 전류 동기 검출 알고리즘)

  • 정영국
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.111-114
    • /
    • 2000
  • Harmonics and fundamental reactive power of nonlinear loads in serious unbalanced power condition are compensated by current synchronous detection(CSD) theory which is also acceptable for single phase power system, but the CSD theory is not suitable any more in case of controlled independently harmonics and reactive component. Therefore a new algorithm the extended current synchronous detection (ECSD)theory for a three phase active power filter based on decomposition of fundamental reactive distorted components is proposed in this paper. The proposed ECSD theory is simulated and tested comparison with a few power theories under asymmtrical condition in power system.

  • PDF

Instantaneous Compensating Current Control of Active Power Filters with Phase Angle Detecting Method Under Unbalance Power System (불평형 전원 시스템하의 위상각 검출에 의한 능동전력필터의 순시보상 전류제어)

  • 정영국
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.752-755
    • /
    • 2000
  • This paper describes a new algorithm for active power filters which can be control source current symmetrically under unbalanced condition in power system. Positive sequency voltage is detected by symmetrical coordinate method and compensating reference current of active power filters is calculated using by accurate phase angle information of positive sequency voltage. The basic principle of the proposed method is described in detail and the conventional and proposed phase detecting methods are compared and discussed through the simulation results.

  • PDF