• Title/Summary/Keyword: 넓은 동적 영역

Search Result 49, Processing Time 0.023 seconds

Implementation of Multi-Band Mobile PIMD Measurement System. (Multi-Band 이동통신용 수동혼변조왜곡 측정시스템 개발)

  • Park, Ki Won;Shin, Dong Whan;Rhee, Young Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.703-705
    • /
    • 2016
  • In this paper, we developed a wideband PIMD system to measure passive intermodulation distortion signals of mobile communication RF passive module. To represent wideband characteristic, we designed a receiver that meets low-noise and wideband characteristics in RF receiver. It allows high dynamic range in the RF receiver front end. In designed passive intermodulation distortion measurement system, we programed to display a PIMD signal with FPGA/DSP at PC. Implemented PIMD system was variable from 650 MHz to 2700 MHz and show up to -138 dB minimum detectable $3^{rd}$ passive inetrmodulation distortion signal.

  • PDF

Design and Fabrication of the Ka-Band Receive Module for Millimeter Wave Seeker (밀리미터파 탐색기를 위한 Ka-대역 수신기 모듈의 설계 및 제작)

  • Yang, Seong-Sik;Lim, Ju-Hyun;Song, Sung-Chan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.1
    • /
    • pp.78-84
    • /
    • 2012
  • In this paper, we introduced the design technique about a Ka band receive module for millimeter wave seekers. The receiver module consists of a waveguide, circulator and transition for antenna connection, and a limiter and gain control amplifier for receiver protection. This module is comprised of a sum, azimuth and elevation channel for receiving monopules signal, and a SLB channel for the acquisition of jamming signal. In this paper, receiver gain and range of gain control dependent on ADC nonlinear characteristic was analyzed and designed for wide dynamic range receive. In the test result of the fabricated Ka-band receive, the frequency band is 1 GHz, the noise figure is as low as 8.2 dB, the gain is $56{\pm}2dB$, the dynamic range is 135 dB, the gain congtrol is more than 86 dB, the channel isolation is more than 35 dB.

Image Quality Analysis According to the of a Linear Transducer (선형 탐촉자에서 관심 시각 영역 변화에 따른 화질 분석)

  • Ji-Na, Park;Jae-Bok, Han;Jong-Gil, Kwak;Jong-Nam, Song
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.975-984
    • /
    • 2022
  • Since a linear transducer has an area of interest equal to the length of the transducer, the area of interest can be expanded using the virtual convex function installed in the device.However, it was thought that the change in the direction of the ultrasonic sound velocity according to the change in the visual area of interest would affect the image quality, so this was objectively confirmed. For this study, image evaluation and SNR·CNR of the phantom for ultrasound quality control were measured. As a result, in the phantom image evaluation, both images were able to identify structures in functional resolution, grayscale, and dynamic range. However, it was confirmed that the standard image was excellent in the reproducibility of the size and shape of the structure. As a result of SNR·CNR evaluation, SNR·CNR of most trapezoidal images was low, except for structures at specific locations. In addition, through the statistical analysis graph, it was further confirmed that the SNR and CNR for each depth decreased as the size of the cystic structure decreased. Through this study, it was confirmed that the use of the function has the advantage of providing a wide visual area of interest, but it has an effect on the image quality. Therefore, when using the virtual convex function, it is judged that the examiner should use it in an appropriate situation and conduct various studies to acquire high-quality images and to improve the understanding and proficiency of the equipment.

Self-calibration of a Multi-camera System using Factorization Techniques for Realistic Contents Generation (실감 콘텐츠 생성을 위한 분해법 기반 다수 카메라 시스템 자동 보정 알고리즘)

  • Kim, Ki-Young;Woo, Woon-Tack
    • Journal of Broadcast Engineering
    • /
    • v.11 no.4 s.33
    • /
    • pp.495-506
    • /
    • 2006
  • In this paper, we propose a self-calibration of a multi-camera system using factorization techniques for realistic contents generation. The traditional self-calibration algorithms for multi-camera systems have been focused on stereo(-rig) camera systems or multiple camera systems with a fixed configuration. Thus, it is required to exploit them in 3D reconstruction with a mobile multi-camera system and another general applications. For those reasons, we suggest the robust algorithm for general structured multi-camera systems including the algorithm for a plane-structured multi-camera system. In our paper, we explain the theoretical background and practical usages based on a projective factorization and the proposed affine factorization. We show experimental results with simulated data and real images as well. The proposed algorithm can be used for a 3D reconstruction and a mobile Augmented Reality.

Design and Implementation of Broadband Power Detector for Six-port Direct Conversion Receiver (Six-port 직접 변환 수신을 위한 광대역 Power detector 설계 제작)

  • Lee, Yong-Ju;Kim, Yeong-Wan;Park, Dong-Cheol
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • The broadband power detector for power amplitude envelope detection of the direct-conversion Six-port output signal was designed and implemented in this paper. The power detector should be linearly operated to produce the linear amplitude and phase signal for input RF signals in required broadband frequency range. The power detector should be designed under conditions of matching circuit with low VSWR, which protect unbalanced phase signal from reflection signal due to mismatch between the output port of a six-port and the input port of a power detector. The designed power detectors, which were implemented in L-band with 50 ohm matching and Ku-band with multiple LC matching circuits and isolator, respectively, were analyzed in viewpoints of the utilization as a power detector of direct conversion Six-port. The dynamic range of designed power detectors were also measured and rvaluated as a power detector of Six-port circuit.

  • PDF

Experimental Comparison on Vibration Attenuation Performances of the Piezoelectric Mount in Same Geometric Constraints with the Rubber Mount (고무마운트와 동일한 형상 조건을 갖는 압전마운트의 진동저감 성능에 대한 실험적 비교 고찰)

  • Han, Young-Min
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.11
    • /
    • pp.166-171
    • /
    • 2021
  • An active mount is devised in same geometric constraints with a conventional rubber mount. The proposed mount features the piezoelectric actuator which can be used to reduce the vibration at marine vessels or automotive vehicles. As a first step, a passive rubber mount is adopted and its dynamic characteristics are experimentally evaluated. Based on the geometry of the rubber mount, a rubber element for the active mount is manufactured and integrated with two piezostacks in series, in which the piezostack is operated as an inertial type of actuator. A conventional PID controller featured by the simple and easy implementation, is then designed to attenuate the non-resonant high frequency vibration transmitted from the base excitation. Finally, the control performances of a proposed active mount are evaluated in the wide frequency range and compared with those of the conventional rubber mount.

A Re-configurable 0.8V 10b 60MS/s 19.2mW 0.13um CMOS ADC Operating down to 0.5V (0.5V까지 재구성 가능한 0.8V 10비트 60MS/s 19.2mW 0.13um CMOS A/D 변환기)

  • Lee, Se-Won;Yoo, Si-Wook;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.3
    • /
    • pp.60-68
    • /
    • 2008
  • This work describes a re-configurable 10MS/s to 100MS/s, low-power 10b two-step pipeline ADC operating at a power supply from 0.5V to 1.2V. MOS transistors with a low-threshold voltage are employed partially in the input sampling switches and differential pair of the SHA and MDAC for a proper signal swing margin at a 0.5V supply. The integrated adjustable current reference optimizes the static and dynamic performance of amplifiers at 10b accuracy with a wide range of supply voltages. A signal-isolated layout improves the capacitor mismatch of the MDAC while a switched-bias power-reduction technique reduces the power dissipation of comparators in the flash ADCs. The prototype ADC in a 0.13um CMOS process demonstrates the measured DNL and INL within 0.35LSB and 0.49LSB. The ADC with an active die area of $0.98mm^2$ shows a maximum SNDR and SFDR of 56.0dB and 69.6dB, respectively, and a power consumption of 19.2mW at a nominal condition of 0.8V and 60MS/s.

Analysis on dynamic numerical model of subsea railway tunnel considering various ground and seismic conditions (다양한 지반 및 지진하중 조건을 고려한 해저철도 터널의 동적 수치모델 분석)

  • Changwon Kwak;Jeongjun Park;Mintaek Yoo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.583-603
    • /
    • 2023
  • Recently, the advancement of mechanical tunnel boring machine (TBM) technology and the characteristics of subsea railway tunnels subjected to hydrostatic pressure have led to the widespread application of shield TBM methods in the design and construction of subsea railway tunnels. Subsea railway tunnels are exposed in a constant pore water pressure and are influenced by the amplification of seismic waves during earthquake. In particular, seismic loads acting on subsea railway tunnels under various ground conditions such as soft ground, soft soil-rock composite ground, and fractured zones can cause significant changes in tunnel displacement and stress, thereby affecting tunnel safety. Additionally, the dynamic response of the ground and tunnel varies based on seismic load parameters such as frequency characteristics, seismic waveform, and peak acceleration, adding complexity to the behavior of the ground-tunnel structure system. In this study, a finite difference method is employed to model the entire ground-tunnel structure system, considering hydrostatic pressure, for the investigation of dynamic behavior of subsea railway tunnel during earthquake. Since the key factors influencing the dynamic behavior during seismic events are ground conditions and seismic waves, six analysis cases are established based on virtual ground conditions: Case-1 with weathered soil, Case-2 with hard rock, Case-3 with a composite ground of soil and hard rock in the tunnel longitudinal direction, Case-4 with the tunnel passing through a narrow fault zone, Case-5 with a composite ground of soft soil and hard rock in the tunnel longitudinal direction, and Case-6 with the tunnel passing through a wide fractured zone. As a result, horizontal displacements due to earthquakes tend to increase with an increase in ground stiffness, however, the displacements tend to be restrained due to the confining effects of the ground and the rigid shield segments. On the contrary, peak compressive stress of segment significantly increases with weaker ground stiffness and the effects of displacement restrain contribute the increase of peak compressive stress of segment.

X-ray properties measurement of Flat panel Digital X-ray gas detector (평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구)

  • Yoon, Min-Seok;Cho, Sung-Ho;Oh, Kyung-Min;Jung, Suk-Hee;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • The Recently, large area matrix-addressed image detectors are investigated for X-ray imaging with medical diagnostic and other applications. In this paper, a new flat panel gas detector for diagnostic X-ray imaging is proposed, and its characteristics are investigated. The research of flat panel gas detector is not exist at all. Because of difficulty to inject gas against to atmospheric pressure. So almost gas detector made by chamber shape. We made flat panel sample by display technique. (ex: PDP, Fed, etc.) The experimental measurements, the transparent electrodes, dielectric layer, and the MgO protection layer were formed in front glass. And, the X-ray phosphor layer and address electrodes are formed in the rare glass. The dark current, the x-ray sensitivity and linearity as a function of electric field were measured to investigate the electrical properties. From the results, the stabilized dark current density and the significant x-ray sensitivity were obtained. And the good linearity as a function of exposure dose was showed in wide diagnostic energy range. These results means that the passive matrix-addressed flat panel gas detector can be used for digital x-ray imaging.

  • PDF