Image Quality Analysis According to the of a Linear Transducer  

Ji-Na, Park (Comprehensive Medical Examination Center, KS Hospital)
Jae-Bok, Han (Department of Radiology, Dongshin University)
Jong-Gil, Kwak (Department of Radiological Technology, Gwangju Health University)
Jong-Nam, Song (Department of Radiology, Dongshin University)
Publication Information
Journal of the Korean Society of Radiology / v.16, no.7, 2022 , pp. 975-984 More about this Journal
Abstract
Since a linear transducer has an area of interest equal to the length of the transducer, the area of interest can be expanded using the virtual convex function installed in the device.However, it was thought that the change in the direction of the ultrasonic sound velocity according to the change in the visual area of interest would affect the image quality, so this was objectively confirmed. For this study, image evaluation and SNR·CNR of the phantom for ultrasound quality control were measured. As a result, in the phantom image evaluation, both images were able to identify structures in functional resolution, grayscale, and dynamic range. However, it was confirmed that the standard image was excellent in the reproducibility of the size and shape of the structure. As a result of SNR·CNR evaluation, SNR·CNR of most trapezoidal images was low, except for structures at specific locations. In addition, through the statistical analysis graph, it was further confirmed that the SNR and CNR for each depth decreased as the size of the cystic structure decreased. Through this study, it was confirmed that the use of the function has the advantage of providing a wide visual area of interest, but it has an effect on the image quality. Therefore, when using the virtual convex function, it is judged that the examiner should use it in an appropriate situation and conduct various studies to acquire high-quality images and to improve the understanding and proficiency of the equipment.
Keywords
Linear transducer; Evaluation of Image Quality; SNR; CNR;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 J. Y. Kim, G. J. An, "Basic Physics and Artifact of Ultrasound", Journal of Clinical Otolaryngology, Vol. 18, No. 2, pp. 135-143, 2007. http://dx.doi.org/10.35420/jcohns.2007.18.2.135   DOI
2 J. P. Jong, "Basic Knowledge of Ultrasonography and Its Clinical Use", Korean Journal of Endocrine Surgery, Vol. 8, No. 1, pp. 1-6, 2008. http://dx.doi.org/10.16956/kjes.2008.8.1.1   DOI
3 C. S. Shim, Abdominal Ultrasound Diagnostics, Focusing on Digestive Disorders, YeoMungak, pp. 24, 2000.
4 S. J. Shin, B. J. Jeong, "Principle and comprehension of ultrasound imaging", Journal of the Korean Orthopaedic Association, Vol. 48, No. 5, PP. 328, 2013. https://doi.org/10.4055/jkoa.2013.48.5.325   DOI
5 M. J. Kim, "Quantitative Evaluation of Ultrasonographic Image Using ATS-539 Multipurpose Phantom", Department of Radiological Science Graduate School, Catholic University of Pusan, Master's degree, 2014.
6 J. H. Park, Y. C. Heo & D. K. Han, "A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom", Journal of the Korean Society of Radiology, Vol. 15, No. 4, pp. 463-472, 2021. https://doi.org/10.7742/jksr.2021.15.4.463   DOI
7 J. G. Kwank, K. R. Dong, J. Y. Shin, N. G. Choi, H. S. Lim & H. S. Kim, "Assessment of image quality according to pressure and position change of transducer during abdominal ultrasonography", Journal of Radiation Industry, Vol. 13, No. 2, pp. 109-118, 2019.
8 M. R. Han, J. G. Kwak, J. N. Song, S. J. Jang, J. B. Han, "Usability Evaluation of Gel Pad Materials for Superficial Structures used in Musculoskeletal Ultrasonography", Journal of the Korean Society of Radiology, Vol. 15, No. 6, pp. 899-909, 2021. https://doi.org/10.7742/jksr.2021.15.6.899   DOI
9 C. S. Kim, S. S. Gang, & J. H. Kim, "Evaluation of Quantitative Image Quality using Frequency and Parameters in the Ultrasound Image", Journal of the Korean Society of Radiology, Vol. 10, No. 4, pp. 247-253, 2016. https://doi.org/10.7742/jksr.2016.10.4.247   DOI
10 Y. H. Seo, J. N. Song, "Analysis of the ESD and DAP According to the Change of the Cine Imaging Condition of Coronary Angiography and Usefulness of SNR and CNR of the Images: Focusing on the Change of Tube Current", Journal of the Korean Society of Radiology, Vol. 13, No. 3, pp. 371-379, 2019. https://doi.org/10.7742/jksr.2019.13.3.371   DOI