Decision of the priority of Fire Endurance and Spatting Prevention Efficiency in High Strength Concrete at High Rise Building Work (초고층 건축공사 고강도 콘크리트 골조의 내화 및 폭렬 방지성능 중요도 선정)

  • Baek, Dae-Hyun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.804-807
    • /
    • 2008
  • Recently, with the increase of high rise and huge scale building construction, the use of high strength concrete has been increasing. High strength concrete has dense pore structure, which is susceptible to be damaged due to fire attack. For this, many researchers provide proper fire endurance method. In this paper, to provide the priority for selecting fire endurance method in high strength concrete execution, AHP technique is applied based on expert questionnaire. Fire endurance performance efficiency and ordinary performance efficiency was selected for level 1. Fire endurance performance efficiency had larger weight than ordinary one.

  • PDF

Fire Resistance Performance of Load Bearing Hybrid Panel Infilled with Light-weight Formed Mortar (복합스터드에 경량기포모르터를 충전한 내력벽체의 내화성능 비교연구)

  • Park, Keum Sung;Bae, Kyu Woong;Kang, Hyun Sik;Lim, Seo Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2007
  • The purpose of this paper is to evaluate the fire resistant performances of load-bearing wall using both composite and steel stud panel infilled with light-weight formed mortar under axial loading according to KS F 2257(1999). The minimum requirement of 2 hours fire resistant rating is needed for the residential and commercial buildings under the fire regulation of Korea. From test results, it is found that two types of specimen composed of the hybrid stud and steel stud panel filled with light-weight formed mortar fited in with the requirement of 2 hours fire resisting rate for the load-bearing wall. In the conclusions, the specimen with hybrid stud shows predominating fire-resistant performance on the adiabatic effects rather than that of the steel stud specimen.

Analytical Study for Improving the Fire Resistance of Composite Beam depend on Section Change (합성보의 단면변경을 통한 내화성능 향상에 관한 해석 연구)

  • Park, Soo-Young;Kim, Hyung-Jun;Hong, Kap-Pyo
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.80-87
    • /
    • 2011
  • On the result of load-bearing fire test to confirm the fire resistance of a composit beam, if the composit beam has lower fire resistance than required standard, it can be improved by section change. But if there are many types of section change, it takes much time and cost owing to conducting many tests. On this study, it was confirmed which part of the asymmetric H-section composit beam affected most on fire resistance by heat-transfer analysis. Then, we checked the tendency of improving fire resistance depend on section change by heat-transfer and non-linear structural analysis and suggested a changed section having 1-hour fire resistance.

An Experimental Study on the Fire Behavior of CFT Column under the Constant Axial Loading Condition in Fire (일정축력을 받는 콘크리트 충전 각형기둥의 경계조건 변화에 따른 화재거동특성에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Min, Byung-Youl;Kwon, In-Kyu;Kwon, Ki-Hyuk
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.69-75
    • /
    • 2010
  • A concrete filled square steel tube (CFT) is composed of the external steel material, which its strength is reduced in fire due to sudden temperature increase, and the internal concrete with high thermal capacity that can ensure the fire resistance performance of the structure. Therefore, research about the influence factors of the structural performance of CFT column is required in order to apply CFT column to a fire resisting structure, and additional research about influence for each condition is also necessary. Among the influence factors, the boundary condition between column and beam is important structurally, and it is one of the major factors that determine overall fire resisting performance. This study performed a fire experiment under loading in order to analyse the influences of CFT column to the boundary condition. As the results of the experiment, fire resistance time of 106 minutes was ensured for the clamped-end condition but 89 minutes for the hinge-end condition in case of the 360 cross section. And, fire resistance time of 113 minutes was ensured for the clamped-end condition but 78 minutes for the hinge-end condition in case of the 280 cross section.

Experimental Study on the Fire Proofing Characteristic of Fire Resistance Panel that it attaches to PSC Airpit-Slab (PSC 풍도슬래브에 부착된 내화패널의 내화특성에 관한 실험연구)

  • Lee, Doo Sung;Bae, Jeong;Choi, Heon;Min, In Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.465-473
    • /
    • 2013
  • In this Study, the performance of precast PSC slabs with fire resistance panel for fire resistance of the tunnel system was evaluated by experimentally. The fire test was performed in fire resistance (electric) furnace according to RABT(Richtlinien fur die Ausstatung und den Betrieb von stra${\beta}$entunneln) time heating temperature curve. The test results showed that the measured temperatures at the t=0 mm depth of PSC slab with precast fire resistance panel during a fire was maximum temperature $367^{\circ}C$, lower than $380^{\circ}C$ (ITA 2004), when damage occurs. Also, at the t=25 mm, the maximum temperature was $239^{\circ}C$, which was lower than the damage temperature of rebar, $250^{\circ}C$. From the results, the use of precast fire resistance panel (t=25 mm) improves fire resistance of PSC structures.

An Experimental Study on Structural Behaviour of Asymmetric H Beam Slim floor under Load Condition in Fire (내화 피복된 비대칭 H형강을 적용한 슬림플로어 보의 재하가열조건 화재거동에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Hyung-Jun;Min, Byung-Youl;Lee, Jae-Sung;Park, Soo-Yong
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.63-71
    • /
    • 2011
  • When it comes to slim floor using asymmetric H-beam, it was designed that the steel member is embedded in concrete with relatively low thermal conductivity so as to minimize the deterioration of rigidity of steel member in fire. But given the bottom flange of asymmetric H-beam is directly exposed to the fire, the measure of applying the fireproof coating to improve the fire rate performance of slim floor beam was sought. The test was aimed at comparing the fireproof performance by adjusting the load ratio of 0.4 and 0.3, and The test was carried out to identify the 3-hour fire performance by reinforcing the beam as well as applying the fireproof coat, In the wake of comparing the specimen depending on variation of load ratio, lowering load ratio by 0.1 resulted in difference of 12 minutes and deflection was 39 mm. It was able to improve 12 minutes by reinforcing the beam and up to 102.4 mm in deflection.

A Study on Assessment of Penetration Seals Performance of Nuclear Power Plants (원자력발전소 관통부 충전구조의 내화성능평가에 관한 연구)

  • Cho Hong-Seok;Park Jun-Hyen;Son Bong-Sae;Im Jung-Soon
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.93-102
    • /
    • 2004
  • The function of fire barrier penetration sealing is highly important to confine a fire propagation a fire severity within a fire area where the fire started. Especially for the penetration seals at the nuclear power plants with the long-term operated history, it is needed to make it clear that the conformance to the sealing requirements has been proven to guarantee the fire-resistive performance of fire barrier penetration parts. If there are any parts of fire barrier penetration sealing which can not meet the required rating for the fire endurance performance, the relevant parts must be modified to meet regulatory requirements. At this paper, the engineering analysis methodology was established to approximate the fire endurance rating for the fire barrier penetration seals. With this study, the method of engineering analysis to decide fire endurance rating for the fire barrier penetration seals was established and this way can be utilized to check the performance of the fire rating for the penetration seal at the domestic nuclear power plants.

Experimental Study on Limiting Temperatures of Structural Beams made with Structural Steel According to Load Ratios (하중비에 따른 강재 보의 한계온도에 관한 실험적 연구)

  • Kwon, In-Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.581-588
    • /
    • 2010
  • Recently the requirements of the buildings built with structural steel were increased in terms of structural stabilities and fire resistance at severe fire conditions. To meet the building regulations of fire resistance, a fire design is needed. This is of a prescriptive method and a performance engineering based method. Recently a simple calculation method as one of performance based engineering method is very popular because of its ease for an application in building built with structural steel. But, in Korea the performance based engineering method is not allowed yet. Thus it is needed to make a guideline for the performance based engineering method. The purpose of this study is to establish the limit temperature derived from structural beams made with both a H-section and a H-section filled with concrete at the web and derived the limit temperatures from beams made with H-sections and found out that the limit temperatures from two kinds of specimens depended on the applied loads and the specimens filled with the concrete represented 3 hour fire resistance in the range of 80%, 60%, and 50% of the maximum load.

Experimental Study on the Fire Resistance of SC Composite Coloumn (SC 합성기둥의 내화성능에 대한 실험연구)

  • Lee, Sueng Jea;Kang, Seong Deok;Oh, Myoung Ho;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.4
    • /
    • pp.425-434
    • /
    • 2007
  • The SC (steel-concrete) composite column was developed to take advantage of the relative economy of using concrete as opposed to steel in carrying large compressive forces. As the SC composite column is pre-fabricated, its use can minimize laborand can speed up the erection of a steel building. In this study, an experiment was conducted to analyze the influence of several parameters, such as the load ratio, the concrete ratio of an area, and its performance with or without fire protection, on the performance of the SC composite column. This paper proposes that the calculation of the strength reduction ratios of columns be done by increasing the temperature. Theoretical equations were used to evaluate the effectiveness of the fire resistance of the SC composite column, and the results of the test and analysis were compared. The fire resistance of the SC composite column was increased by decreasing its load ratio, but the concrete ratio of an area has minimal influence on the fire resistance of the SC composite column.

Evaluation on the Fire Resistance Performance for High-Rise Modular Walls (중·고층형 모듈러 벽체의 내화성능 평가)

  • Yang, Seung-Cho;Lee, Jae-Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.15-22
    • /
    • 2019
  • The use of modular buildings is increasing because of various advantages of modular buildings. But there are limits to apply modular buildings to medium-rise buildings because the building law provides only the specification criteria of the modular building with respect to the 1 hour fire resistance performance. This study was conducted to investigate 2 hours fire resistance performance of load bearing walls with steel studs in modular buildings by KS F 2257-1 and KS F 2257-4. After full scale tests, load bearing walls ensuring two hours fire resistance performance consist of at least 2 layers of fire resistance plaster boards of 19mm thickness or 3 layer of fire resistance plaster boards of thickness.